Evaluation of strength criteria for very-high-strength concretes under triaxial compression

被引:1
作者
Girgin, Z. Canan [1 ]
Arioglu, Nihal
Arioglu, Ergin
机构
[1] Yildiz Tech Univ, Istanbul, Turkey
[2] Istanbul Tech Univ, TR-80626 Istanbul, Turkey
[3] Yapt Merkezi Inc, Dept Res & Dev, Istanbul, Turkey
关键词
compressive strength; high-strength concrete; splitting tensile strength; ultimate strength;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, the empirical relationships proposed in the current literature were verified to assess their validity for compressive strengths between 66 and 132 MPa (8700 to 19,145 psi). A relationship was suggested to predict the ultimate strength 4 very high-strength concrete under triaxial compression. Furthermore, strength criteria essentially developed to estimate the ultimate strength of intact rock were applied to the concrete. The results of triaxial tests were employed to verify the applicability of these strength criteria for high-strength concrete. It is interesting to note that the strength criteria developed for intact rocks can also be applied to the assessment of ultimate strength and failure curve in high-strength concretes. Knowing only the cylinder compressive strength and the ratio of tensile-to-compressive strength, the failure envelope can be successfully evaluated by means of these criteria without performing triaxial tests in high-strength concretes.
引用
收藏
页码:278 / 284
页数:7
相关论文
共 25 条
[1]  
[Anonymous], 1992, ACI J P
[2]  
Aroglu N, 2006, ACI MATER J, DOI [10.14359/15123, DOI 10.14359/15123]
[3]  
ARTOGLU E, 2004, CONCRETE PREFABRICAT, P5
[4]  
ARTOGLU E, 1999, P 5 INT S UT HIGH ST, V2, P981
[5]  
Attard MM, 1996, ACI MATER J, V93, P432
[6]  
BALMER G, 1952, AM SOC TEST MAT, V52, P1260
[7]  
BALMER GG, 1949, SP23 US BUR RECL
[8]  
Bing L, 2001, ACI STRUCT J, V98, P395
[9]  
*CEB FIP MOD COD C, 1991, B INF, V199
[10]  
HOEK E, 1980, J GEOTECH ENG-ASCE, V106, P1013