Global longitudinal strain software upgrade: Implications for intervendor consistency and longitudinal imaging studies

被引:16
作者
Castel, Anne-Laure [1 ]
Menet, Aymeric [1 ,2 ]
Ennezat, Pierre-Vladimir [3 ]
Delelis, Francois [1 ]
Le Goffic, Caroline [1 ]
Binda, Camille [1 ]
Guerbaai, Raphaelle-Ashley [3 ]
Levy, Franck [4 ]
Graux, Pierre [1 ]
Tribouilloy, Christophe [2 ,5 ]
Marechaux, Sylvestre [1 ,2 ]
机构
[1] Univ Catholique Lille, Univ Lille Nord France, GCS Grp Hop,Inst Catholique Lille, Fac Libre Med, Lille, France
[2] Univ Picardie, INSERM, U1088, Amiens, France
[3] Ctr Hosp Univ Grenoble, Grenoble, France
[4] Ctr Cardiothorac, Monaco, Monaco
[5] Ctr Hosp Univ Amiens, Amiens, France
关键词
Echocardiography; Longitudinal strain; Speckle tracking; SPECKLE TRACKING ECHOCARDIOGRAPHY; EJECTION FRACTION; MYOCARDIAL DEFORMATION; 2-DIMENSIONAL STRAIN; VALIDATION; VENDORS;
D O I
10.1016/j.acvd.2015.08.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Speckle tracking can be used to measure left ventricular global longitudinal strain (GLS). Aims. To study the effect of speckle tracking software product upgrades on GLS values and intervendor consistency. Methods. Subjects (p atients or healthy volunteers) underwent systematic echocardiography with equipment from Philips and GE, without a change in their position. Off-line post-processing for GLS assessment was performed with the former and most recent upgrades from these two vendors (Philips QLAB 9.0 and 10.2; GE EchoPAC 12.1 and 13.1.1). GLS was obtained in three myocardial layers with EchoPAC 13.1.1. Intersoftware and intervendor consistency was assessed. Interobserver variability was tested in a subset of patients. Results. Among 73 subjects (65 patients and 8 healthy volunteers), absolute values of GLS were higher with QLAB 10.2 compared with 9.0 (intraclass correlation coefficient [ICC]: 0.88; bias: 2.2%). Agreement between EchoPAC 13.1.1 and 12.1 varied by myocardial layer (13.1.1 only): midwalt (ICC: 0.95; bias: -1.1%), endocardium (ICC: 0.93; bias: 1.6%) and epicardial (ICC: 0.80; bias: -3.3%). Although GLS was comparable for QLAB 9.0 versus EchoPAC 12.1 (ICC: 0.95; bias: 0.5%), the agreement was lower between QLAB 10.2 and EchoPAC 13.1.1 endocardial (ICC: 0.91; bias: 1.1%), midwall (ICC: 0.73; bias: 3.9%) and epicardial (ICC: 0.54; bias: 6.0%). Interobserver variability of all software products in a subset of 20 patients was excellent (ICC: 0.97-0.99; bias: -0.8 to 1.0%). Conclusion. Upgrades of speckle tracking software may be associated with significant changes in GLS values, which could affect intersoftware and intervendor consistency. This finding has important clinical implications for the longitudinal follow-up of patients with speckle tracking echocardiography. (C) 2015 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:22 / 30
页数:9
相关论文
共 23 条
[1]   Noninvasive myocardial strain measurement by speckle tracking echocardiography - Validation against sonomicrometry and tagged magnetic resonance imaging [J].
Amundsen, BH ;
Helle-Valle, T ;
Edvardsen, T ;
Torp, H ;
Crosby, J ;
Lyseggen, E ;
Stoylen, A ;
Ihlen, H ;
Lima, JAC ;
Smiseth, OA ;
Slordahl, SA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) :789-793
[2]   Feasibility and Accuracy of Different Techniques of Two-Dimensional Speckle Based Strain and Validation With Harmonic Phase Magnetic Resonance Imaging [J].
Bansal, Manish ;
Cho, Goo-Yeong ;
Chan, Jonathan ;
Leano, Rodel ;
Haluska, Brian A. ;
Marwick, Thomas H. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (12) :1318-1325
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Prospective comparison of speckle tracking longitudinal bidimensional strain between two vendors [J].
Castel, Anne-Laure ;
Szymanski, Catherine ;
Delelis, Francois ;
Levy, Franck ;
Menet, Aymeric ;
Mailliet, Amandine ;
Marotte, Nathalie ;
Graux, Pierre ;
Tribouilloy, Christophe ;
Marechaux, Sylvestre .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2014, 107 (02) :96-104
[5]   Quantification of the Variability Associated with Repeat Measurements of Left Ventricular Two-Dimensional Global Longitudinal Strain in a Real-World Setting [J].
Costa, Salvatore P. ;
Beaver, Timothy A. ;
Rollor, Joyce L. ;
Vanichakarn, Pantila ;
Magnus, Patrick C. ;
Palac, Robert T. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (01) :50-54
[6]   The limits of agreement and the intraclass correlation coefficient may be inconsistent in the interpretation of agreement [J].
Costa-Santos, Cristina ;
Bernardes, Joao ;
Ayres-de-Campos, Diogo ;
Costa, Antonia ;
Costa, Celia .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2011, 64 (03) :264-269
[7]   Longitudinal Myocardial Strain Alteration Is Associated with Left Ventricular Remodeling in Asymptomatic Patients with Type 2 Diabetes Mellitus [J].
Ernande, Laura ;
Bergerot, Cyrille ;
Girerd, Nicolas ;
Thibault, Helene ;
Davidsen, Einar Skulstad ;
Pignon-Blanc, Pierre Gautier ;
Amaz, Camille ;
Croisille, Pierre ;
De Buyzere, Marc L. ;
Rietzschel, Ernst R. ;
Gillebert, Thierry C. ;
Moulin, Philippe ;
Altman, Mikhael ;
Derumeaux, Genevieve .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (05) :479-488
[8]   A Practical Approach to Using Strain Echocardiography to Evaluate the Left Ventricle [J].
Feigenbaum, Harvey ;
Mastouri, Ronald ;
Sawada, Stephen .
CIRCULATION JOURNAL, 2012, 76 (07) :1550-1555
[9]   LV Mechanics in Mitral and Aortic Valve Diseases Value of Functional Assessment Beyond Ejection Fraction [J].
Galli, Elena ;
Lancellotti, Patrizio ;
Sengupta, Partho P. ;
Donal, Erwan .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (11) :1151-1166
[10]   Two-dimensional strain - A novel software for real-time quantitative echocardiographic assessment of myocardial function [J].
Leitman, M ;
Lysyansky, P ;
Sidenko, S ;
Shir, V ;
Peleg, E ;
Binenbaum, M ;
Kaluski, E ;
Krakover, R ;
Vered, Z .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (10) :1021-1029