An 18.6-μW/Ch TDM-Based 8-Channel Noncontact ECG Recording IC With Common-Mode Interference Suppression

被引:5
作者
Choi, Kyu-Jin [1 ]
Sim, Jae-Yoon [1 ]
机构
[1] Pohang Univ Sci & Technol, Dept Elect & Elect Engn, Pohang 790784, South Korea
基金
新加坡国家研究基金会;
关键词
Biopotential readout; common-mode interference (CMI); electrocardiogram (ECG); noncontact monitoring; time-division multiplexing (TDM); MULTISENSOR; REDUCTION; ELECTRODE; SYSTEM; SOC;
D O I
10.1109/TBCAS.2022.3229673
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents an 8-channel electrocardiogram (ECG) monitoring integrated circuit (IC) controlled by time-division multiplexing (TDM). The proposed TDM compensates the electrode DC offsets by forming an individual discrete-time feedback loop per channel while sharing an analog frontend. This enables a chopping-free open-loop amplification, achieving a high input impedance suitable for a noncontact ECG monitoring. In addition, a common-mode interference (CMI) cancellation scheme is also introduced in the proposed TDM schedule for the realization of a pseudo-driven-right leg (DRL) in a multichannel environment. The designed system is implemented in 180 nm CMOS. The chip dissipates 18.6 mu W/channel including the power consumption by ADC. It shows the total-CMRR of 100 dB against CMI voltage swing up to 20 V-PP. The chip is verified in noncontact 8-channel ECG using conventional passive electrodes.
引用
收藏
页码:1021 / 1029
页数:9
相关论文
共 31 条
  • [1] [Anonymous], 2020, GLOB HLTH EST 2019 L
  • [2] A 400 GΩ Input-Impedance Active Electrode for Non-Contact Capacitively Coupled ECG Acquisition With Large Linear-Input-Range and High CM-Interference-Tolerance
    Chen, Mingyi
    Chun, Ho Sung
    Castro, Ivan Dario
    Torfs, Tom
    Lin, Qiuyang
    van Hoof, Chris
    Wang, Guoxing
    Lian, Yong
    van Helleputte, Nick
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2019, 13 (02) : 376 - 386
  • [3] Ultra-High Input Impedance, Low Noise Integrated Amplifier for Noncontact Biopotential Sensing
    Chi, Yu M.
    Maier, Christoph
    Cauwenberghs, Gert
    [J]. IEEE JOURNAL ON EMERGING AND SELECTED TOPICS IN CIRCUITS AND SYSTEMS, 2011, 1 (04) : 526 - 535
  • [4] Choi K. -J., 2022, PROC IEEE INT SOLIDS, P1
  • [5] An 84.6-dB-SNDR and 98.2-dB-SFDR Residue-Integrated SAR ADC for Low-Power Sensor Applications
    Choi, Seungnam
    Ku, Hwan-Seok
    Son, Hyunwoo
    Kim, Byungsub
    Park, Hong-June
    Sim, Jae-Yoon
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2018, 53 (02) : 404 - 417
  • [6] A Digitally Assisted Multiplexed Neural Recording System With Dynamic Electrode Offset Cancellation via an LMS Interference-Canceling Filter
    Fathy, Nader Sherif Kassem
    Huang, Jiannan
    Mercier, Patrick P.
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2022, 57 (03) : 953 - 964
  • [7] A Textile Integrated Long-Term ECG Monitor with Capacitively Coupled Electrodes
    Fuhrhop, Silvester
    Lamparth, Stefan
    Heuer, Stephan
    [J]. 2009 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS 2009), 2009, : 21 - +
  • [8] AN ECONOMICAL CLASS OF DIGITAL-FILTERS FOR DECIMATION AND INTERPOLATION
    HOGENAUER, EB
    [J]. IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1981, 29 (02): : 155 - 162
  • [9] A 43.3-μW Biopotential Amplifier With Tolerance to Common-Mode Interference of 18 Vpp and T-CMRR of 105 dB in 180-nm CMOS
    Koo, Nahmil
    Kim, Hyojun
    Cho, Seonghwan
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2023, 58 (02) : 508 - 519
  • [10] A 24.8-μW Biopotential Amplifier Tolerant to 15-VPP Common-Mode Interference for Two-Electrode ECG Recording in 180-nm CMOS
    Koo, Nahmil
    Cho, Seonghwan
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2021, 56 (02) : 591 - 600