Significant reduction of patellar height affected lower clinical outcomes and knee flexion over five-year follow-up after total knee arthroplasty

被引:10
|
作者
Suthar, A. [1 ]
Yukata, K. [1 ,3 ]
Azuma, Y. [1 ]
Suetomi, Y. [1 ]
Yamazaki, K. [2 ,3 ]
Seki, K. [2 ,3 ]
Sakai, T. [2 ,3 ]
Fujii, H. [1 ]
机构
[1] Ogori Daiichi Gen Hosp, Dept Orthoped Surg, Yamaguchi, Japan
[2] Ogori Daiichi Gen Hosp, Yamaguchi, Japan
[3] Yamaguchi Univ, Dept Orthoped Surg, Sch Med, Ube, Yamaguchi, Japan
来源
BONE & JOINT OPEN | 2021年 / 2卷 / 12期
关键词
Insall-Salvati ratio; Patella baja; Patellar tendon shortening; Total knee arthroplasty; TENDON LENGTH; AGREEMENT; EVERSION;
D O I
10.1302/2633-1462.212.BJO-2021-0164.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA). Methods We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height reduction beyond measurement error and clinical outcomes. Results The ISR gradually decreased over five years after TKA, and finally 33 patients (20.0%) had patella baja. Patella baja at the final follow-up was not related to passive knee ROM or KSS. Interestingly, when we divided into two groups - patella baja and patella normal-alta (ISR >= 0.8) - the patella baja group already had a lower patellar height before surgery, compared with the patella normal-alta group. The ISR measurement error in this study was 0.17. Both passive knee flexion and KSS were significantly decreased in the group with a decrease in ISR of >= 0.17 at final follow-up. Conclusion Patellar height gradually decreased over five years of follow-up after TKA. The reduction in patellar height beyond measurement error following TKA was associated with lower clinical outcomes.
引用
收藏
页码:1075 / 1081
页数:7
相关论文
共 50 条
  • [21] Five-year results after total knee arthroplasty in lymphoedema and lipoedema: encouraging functional and clinical outcomes and low rates of infection
    Granger, Luke
    Bolam, Scott M.
    Sur, Avtar
    Mitchell, Philip
    Hutt, Jonathan
    Sandiford, Nemandra A.
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (12) : 2815 - 2820
  • [22] Total Knee Replacement Arthroplasty with Buechel and Pappas Knee: Minimum 2-Year Follow-up
    Moon, Kyoung Ho
    Hong, Seung Hyun
    Hong, Taek Ho
    CLINICS IN ORTHOPEDIC SURGERY, 2015, 7 (01) : 62 - 68
  • [23] Clinical outcomes and patient satisfaction after total knee arthroplasty: a follow-up of the first 50 cases by a single surgeon
    West, Jacob A.
    Scudday, Travis
    Anderson, Scott
    Amin, Nirav H.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (04) : 1667 - 1676
  • [24] Bone mineral density changes after total knee arthroplasty: One-year follow-up
    Gazdzik, Tadeusz S.
    Gajda, Tomasz
    Kaleta, Marek
    JOURNAL OF CLINICAL DENSITOMETRY, 2008, 11 (03) : 345 - 350
  • [25] Predictors and Prevalence of Persistent Pain after Total Knee Arthroplasty in One-Year Follow-up
    Fard, Mehdi Motifi
    Jazaiery, Seyyed Mahdi
    Ghaderi, Milad
    Ravanbod, Hadi
    Taravati, Amir Mohammad
    Rostami, Koushan
    Shahrokh, Seyedeh Ghazal
    ADVANCED BIOMEDICAL RESEARCH, 2024, 13 (01):
  • [26] Total knee arthroplasty with the Medial-Pivot knee system: Clinical and radiological outcomes at 9.5 years' mean follow-up
    Dehl, M.
    Bulaid, Y.
    Chelli, M.
    Belhaouane, R.
    Gabrion, A.
    Havet, E.
    Mertl, P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (02) : 185 - 191
  • [27] Safety and Efficacy of a Rotating-Platform, High-Flexion Knee Design Three- to Five-Year Follow-Up
    Meftah, Morteza
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (02) : 201 - 206
  • [28] Clinical and Functional Outcomes of Kinematic Aligned Total Knee Arthroplasty with a Medial Pivot Design: Two-Year Follow-Up
    Sosio, Corrado
    Rossi, Nicolo
    Sirtori, Paolo
    Ciliberto, Ricardo
    Lombardo, Michele Davide Maria
    Peretti, Giuseppe Michele
    Mangiavini, Laura
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)
  • [29] Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending?
    Cho, Sung-Do
    Youm, Yoon-Seok
    Park, Ki-Bong
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (06) : 899 - 903
  • [30] Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending?
    Sung-Do Cho
    Yoon-Seok Youm
    Ki-Bong Park
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 899 - 903