Back to the Basics: Biochemical Testing for Pathogen Identification in the Era of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS)

被引:4
作者
Pandey, Utsav [1 ]
Naccache, Samia N. [2 ]
Bard, Jennifer Dien [1 ,3 ]
机构
[1] Childrens Hosp Los Angeles, Dept Pathol & Lab Med, Los Angeles, CA 90027 USA
[2] LabCorp Diagnost Labs, Seattle, WA USA
[3] Univ Southern Calif, Keck Sch Med, Los Angeles, CA 90033 USA
关键词
biochemicals; MALDI-TOF MS; misidentification; Neisseria gonorrhoeae; MISIDENTIFICATION;
D O I
10.1128/JCM.00498-19
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
引用
收藏
页数:3
相关论文
共 9 条
  • [1] An Investigation into Laboratory Misidentification of a Bloodstream Klebsiella variicola Infection
    Berry, Gregory J.
    Loeffelholz, Michael J.
    Williams-Bouyer, Natalie
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (08) : 2793 - 2794
  • [2] Misidentification of Neisseria polysaccharea as Neisseria meningitidis with the Use of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry
    Cunningham, Scott A.
    Mainella, Jill M.
    Patel, Robin
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (06) : 2270 - 2271
  • [3] Closing the Brief Case: Klebsiella variicola-Identifying the Misidentified
    Fontana, Lauren
    Bonura, Erin
    Lyski, Zoe
    Messer, William
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2019, 57 (01)
  • [4] Misidentification of Neisseria cinerea as Neisseria meningitidis by Matrix-Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry (MALDI-TOF MS)
    Kawahara-Matsumizu, Miyako
    Yamagishi, Yuka
    Mikamo, Hiroshige
    [J]. JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2018, 71 (01) : 85 - 87
  • [5] CHROMagar™ orientation urine culture medium produces matrix-assisted laser desorption ionization-time-of-flight mass spectrometry spectra misidentified as Mycoplasma arginini and Mycoplasma alkalescens
    Lagace-Wiens, Philippe R. S.
    Abbott, Amanda A.
    Karlowsky, James A.
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2019, 94 (02) : 113 - 115
  • [6] Direct Identification of Aerobic Bacteria by Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry Is Accurate and Robust
    Mestas, Javier
    Quias, Teephany
    Bard, Jennifer Dien
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2016, 30 (05) : 543 - 551
  • [7] The Brief Case: Misidentification of Brucella melitensis as Ochrobactrum anthropi by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS)
    Poonawala, Husain
    Conner, Tracy Marrs
    Peaper, David R.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2018, 56 (06)
  • [8] Identification of Enterobacteriaceae by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using the VITEK MS system
    Richter, S. S.
    Sercia, L.
    Branda, J. A.
    Burnham, C. -A. D.
    Bythrow, M.
    Ferraro, M. J.
    Garner, O. B.
    Ginocchio, C. C.
    Jennemann, R.
    Lewinski, M. A.
    Manji, R.
    Mochon, A. B.
    Rychert, J. A.
    Westblade, L. F.
    Procop, G. W.
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2013, 32 (12) : 1571 - 1578
  • [9] Evaluation of Several Biochemical and Molecular Techniques for Identification of Streptococcus pneumoniae and Streptococcus pseudopneumoniae and Their Detection in Respiratory Samples
    Wessels, Els
    Schelfaut, Jacqueline J. G.
    Bernards, Alexandra T.
    Claas, Eric C. J.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (04) : 1171 - 1177