Influence of monte carlo variance with fluence smoothing in VMAT treatment planning with Monaco TPS

被引:11
作者
Sarkar, B. [1 ]
Manikandan, A. [2 ]
Nandy, M. [3 ]
Munshi, A. [4 ]
Sayan, P. [4 ]
Sujatha, N. [5 ]
机构
[1] AMRI Hosp, Dept Radiat Oncol, Kolkata, India
[2] Narayana Hrudayala, Dept Radiat Oncol, Bangalore, Karnataka, India
[3] Saha Inst Nucl Phys, Div Chem Sci, Guntur, Andhra Pradesh, India
[4] Fortis Mem Res Inst, Dept Radiat Oncol, Gurgaon, Haryana, India
[5] Guntur Med Coll, Dept Radiat Oncol, Guntur, Andhra Pradesh, India
关键词
Fluence smoothening factor; monte carlo; volumetric modulated arc therapy; VOLUMETRIC MODULATED ARC; RADIATION-THERAPY; IMRT; IMPLEMENTATION;
D O I
10.4103/0019-509X.180820
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
INTRODUCTION: The study aimed to investigate the interplay between Monte Carlo Variance (MCV) and fluence smoothing factor (FSF) in volumetric modulated arc therapy treatment planning by using a sample set of complex treatment planning cases and a X-ray Voxel Monte Carlo-based treatment planning system equipped with tools to tune fluence smoothness as well as MCV. MATERIALS AND METHODS: The dosimetric (dose to tumor volume, and organ at risk) and physical characteristic (treatment time, number of segments, and so on) of a set 45 treatment plans for all combinations of 1%, 3%, 5% MCV and 1, 3, 5 FSF were evaluated for five carcinoma esophagus cases under the study. RESULT: Increase in FSF reduce the treatment time. Variation of MCV and FSF gives a highest planning target volume (PTV), heart and lung dose variation of 3.6%, 12.8% and 4.3%, respectively. The heart dose variation was highest among all organs at risk. Highest variation of spinal cord dose was 0.6 Gy. CONCLUSION: Variation of MCV and FSF influences the organ at risk (OAR) doses significantly but not PTV coverage and dose homogeneity. Variation in FSF causes difference in dosimetric and physical parameters for the treatment plans but variation of MCV does not. MCV 3% or less do not improve the plan quality significantly (physical and clinical) compared with MCV greater than 3%. The use of MCV between 3% and 5% gives similar results as 1% with lesser calculation time. Minimally detected differences in plan quality suggest that the optimum FSF can be set between 3 and 5.
引用
收藏
页码:158 / 161
页数:4
相关论文
共 50 条
  • [41] Comparison of adjoint and forward Monte Carlo based treatment planning for a realistic head phantom
    Nievaart, S.
    Moss, R.
    Wittig, A.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S115 - S117
  • [42] Commissioning a fast Monte Carlo dose calculation algorithm for lung cancer treatment planning
    Craig, Jeff
    Oliver, Mike
    Gladwish, Adam
    Mulligan, Matt
    Chen, Jeff
    Wong, Eugene
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (02): : 83 - 97
  • [43] Uncertainty reduction in intensity modulated proton therapy by inverse Monte Carlo treatment planning
    Moravek, Zdenek
    Rickhey, Mark
    Hartmann, Matthias
    Bogner, Ludwig
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15) : 4803 - 4819
  • [44] Evaluation of a commercial electron treatment planning system based on Monte Carlo techniques (eMC)
    Pemler, Peter
    Besserer, Juergen
    Schneider, Uwe
    Neuenschwander, Hans
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2006, 16 (04): : 313 - 329
  • [45] 4D Monte Carlo dose calculations for pre-treatment quality assurance of VMAT SBRT: a phantom-based feasibility study
    Roberts, Natalia F.
    Williams, Matthew
    Holloway, Lois
    Metcalfe, Peter
    Oborn, Bradley M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21)
  • [46] A Monte Carlo-based treatment-planning tool for ion beam therapy
    Boehlen, T. T.
    Bauer, J.
    Dosanjh, M.
    Ferrari, A.
    Haberer, T.
    Parodi, K.
    Patera, V.
    Mairani, A.
    JOURNAL OF RADIATION RESEARCH, 2013, 54 : 77 - 81
  • [47] Multileaf collimator tongue-and-groove effect on depth and off-axis doses: A comparison of treatment planning data with measurements and Monte Carlo calculations
    Kim, Hee Jung
    Kim, Siyong
    Park, Yang-Kyun
    Kim, Jung-in
    Park, Jong Min
    Ye, Sung-Joon
    MEDICAL DOSIMETRY, 2015, 40 (04) : 271 - 278
  • [48] Monte Carlo modeling of HD120 multileaf collimator on Varian TrueBeam linear accelerator for verification of 6X and 6X FFF VMAT SABR treatment plans
    Bergman, Alanah M.
    Gete, Ermias
    Duzenli, Cheryl
    Teke, Tony
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03): : 148 - 163
  • [49] Assessing dose variance from immobilization devices in VMAT head and neck treatment planning: A retrospective case study analysis
    Olson, Alyssa
    Phillips, Kristine
    Eng, Tamara
    Lenards, Nishele
    Hunzeker, Ashley
    Lewis, Daniel
    Baumann, Douglas
    MEDICAL DOSIMETRY, 2018, 43 (01) : 39 - 45
  • [50] PRIMO Monte Carlo software as a tool for commissioning of an external beam radiotherapy treatment planning system
    Calvo-Ortega, Juan-Francisco
    Hermida-Lopez, Marcelino
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2023, 28 (04) : 529 - 540