A novel amperometric biosensor based on artichoke (Cynara scolymus L.) tissue homogenate immobilized in gelatin for hydrogen peroxide detection

被引:0
作者
Öztürk, G
Ertas, FN
Akyilmaz, E
Dinçkaya, E
Tural, H
机构
[1] Ege Univ, Fac Sci, Dept Chem, TR-35100 Izmir, Turkey
[2] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Izmir, Turkey
来源
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY | 2004年 / 32卷 / 04期
关键词
hydrogen peroxide; biosensor; artichoke (Cynara scolymus L.); tissue homogenate based electrode; amperometry;
D O I
10.1081/LABB-200039660
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A biosensor for specific determination of hydrogen peroxide was developed by using homogenized artichoke (Cynara scolymus L.) tissue in combination with a dissolved oxygen probe and applied in determination of hydrogen peroxide in milk samples. Artichoke tissue, which has catalase activity, was immobilized with gelatine by means of glutaraldehyde and fixed on a pretreated teflon membrane. The electrode response was maximum when 0.05 M phosphate buffer was used at pH 7.0 and at 30degreesC. Upon addition of hydrogen peroxide, the electrode gives a linear response in a concentration range of 5.0-50x10(-5) M with a response time of 3 min. The method was also applied to the determination of hydrogen peroxide in milk samples.
引用
收藏
页码:637 / 645
页数:9
相关论文
共 28 条
  • [21] A mediator-free amperometric hydrogen peroxide biosensor based on HRP immobilized on a nano-Au/poly 2,6-pyridinediamine-coated electrode
    Shurui Cao
    Ruo Yuan
    Yaqin Chai
    Lingyan Zhang
    Xuelian Li
    Fengxian Gao
    [J]. Bioprocess and Biosystems Engineering, 2007, 30 : 71 - 78
  • [22] A novel enzymatic biosensor for detection of intracellular hydrogen peroxide based on 1-aminopyrene and reduced graphene oxides
    Zou, Na
    Wei, Xianyong
    Zong, Zhimin
    Li, Xin
    Wang, Zhaoxia
    Wang, Xueliang
    [J]. JOURNAL OF CHEMICAL SCIENCES, 2019, 131 (04)
  • [23] A novel enzymatic biosensor for detection of intracellular hydrogen peroxide based on 1-aminopyrene and reduced graphene oxides
    Na Zou
    Xianyong Wei
    Zhimin Zong
    Xin Li
    Zhaoxia Wang
    Xueliang Wang
    [J]. Journal of Chemical Sciences, 2019, 131
  • [24] Synergistic catalysis and detection of hydrogen peroxide based on a 3D-dimensional molybdenum disulfide interspersed carbon nanotubes nanonetwork immobilized chloroperoxidase biosensor
    Zhu, Xuefang
    He, Meng
    Zhang, Jing
    Jiang, Yucheng
    [J]. BIOELECTROCHEMISTRY, 2023, 154
  • [25] A Novel Non-Enzymatic PEDOT:PSS/GO/MnO2 Based Biosensor For Hydrogen Peroxide Detection in Biological Samples
    Sirdeshmukh, Vedashree V.
    Kadu, Indrayani S.
    Mishra, Shreshtha S.
    Kale, Anup A.
    [J]. 2019 13TH IEEE INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE & ENGINEERING (IEEE-NANOMED 2019), 2019, : 251 - 255
  • [26] A new amperometric biosensor based on HRP/nano-Au/L-cysteine/poly(o-aminobenzoic acid)-membrane-modified platinum electrode for the determination of hydrogen peroxide
    Tang Ming-Yu
    Yuan Ruo
    Chai Ya-Qin
    [J]. CHINESE JOURNAL OF CHEMISTRY, 2006, 24 (11) : 1575 - 1580
  • [27] Real-time detection of L-ascorbic acid and hydrogen peroxide in crude food samples employing a reversed sequential differential measuring technique of the SIRE-technology based biosensor
    Kriz, K
    Anderlund, M
    Kriz, D
    [J]. BIOSENSORS & BIOELECTRONICS, 2001, 16 (06) : 363 - 369
  • [28] A high-sensitive amperometric hydrogen peroxide biosensor based on the immobilization of hemoglobin on gold colloid/L-cysteine/gold colloid/nanoparticles Pt-chitosan composite film-modified platinum disk electrode
    Yang, Gan
    Yuan, Ruo
    Chai, Ya-Qin
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2008, 61 (01) : 93 - 100