Safety and Efficacy of Implantation of the Bonebridge Active Transcutaneous Bone-Conduction Device Using Implant Lifts

被引:6
作者
Brkic, Faris F. [1 ]
Riss, Dominik [1 ]
Arnoldner, Christoph [1 ]
Liepins, Rudolfs [1 ]
Gstoettner, Wolfgang [1 ]
Baumgartner, Wolf-Dieter [1 ]
Vyskocil, Erich [1 ]
机构
[1] Med Univ Vienna, Dept Otorhinolaryngol Head & Neck Surg, Vienna, Austria
关键词
implant lifts; Bonebridge; complications; audiologic outcomes; HEARING IMPLANT; INDICATION CRITERIA; COMPLICATIONS; OUTCOMES; CHILDREN;
D O I
10.1055/s-0041-1723038
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Background Implant lifts were recently introduced to facilitate implantation of the Bonebridge and to reduce the risk of uncovering the sigmoid sinus and/or dura. Purpose The current study analyzed medical, technical, and audiological outcomes of implantation with the Bonebridge implant using lifts. Research Design This was a retrospective study on all consecutive patients implanted with a bone-conduction hearing implant at a tertiary medical referral center between March 2012 and October 2018. Outcome measures were complications, explantations, and revisions and the mean time of implant use. Audiological results were assessed as well. Outcomes were evaluated for devices implanted with BCI Lifts and compared with those implanted without lifts. Results In the study period, 13 out of a total of 54 implantations were conducted using one or two 1- to 4-mm BCI Lifts. During the follow-up period, two complications occurred and both in patients implanted without lifts (2/41; 4.9%). All patients in the lifts group were using the implant at the end of observation period. No statistically significant difference was observed in functional hearing gain or word-recognition improvement at 65dB between two groups. Conclusions The use of BCI Lifts in Bonebridge implantations was not associated with adverse events during the observation period. The clinical follow-up revealed no complications in implantations requiring lifts. Furthermore, the functional hearing gain and the word-recognition improvement did not differ from those of devices implanted without lifts. Data indicate safety and efficacy for Bonebridge implantations using lifts.
引用
收藏
页码:290 / 294
页数:5
相关论文
共 16 条
[11]   Indication Criteria and Outcomes With the Bonebridge Transcutaneous Bone-Conduction Implant [J].
Riss, Dominik ;
Arnoldner, Christoph ;
Baumgartner, Wolf-Dieter ;
Blineder, Michaela ;
Flak, Stefan ;
Bachner, Anna ;
Gstoettner, Wolfgang ;
Hamzavi, Jafar-Sasan .
LARYNGOSCOPE, 2014, 124 (12) :2802-2806
[12]   Safety and effectiveness of the Bonebridge transcutaneous active direct-drive bone-conduction hearing implant at 1-year device use [J].
Schmerber, Sebastien ;
Deguine, O. ;
Marx, M. ;
Van de Heyning, P. ;
Sterkers, O. ;
Mosnier, I. ;
Garin, P. ;
Godey, B. ;
Vincent, C. ;
Venail, F. ;
Mondain, M. ;
Deveze, A. ;
Lavieille, J. P. ;
Karkas, A. .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (04) :1835-1851
[13]   The Bonebridge Bone Conduction Hearing Implant: indication criteria, surgery and a systematic review of the literature [J].
Sprinzl, G. M. ;
Wolf-Magele, A. .
CLINICAL OTOLARYNGOLOGY, 2016, 41 (02) :131-143
[14]   Transmastoid implantability of an active transcutaneous bone conduction implant in adults with regard to the underlying pathology: a radiological simulation study [J].
Thomas, Jan Peter ;
van Ackeren, Konstantin ;
Dazert, Stefan ;
Todt, Ingo ;
Prescher, Andreas ;
Voelter, Christiane .
ACTA OTO-LARYNGOLOGICA, 2018, 138 (06) :530-536
[15]   Dura and sinus compression with a transcutaneous bone conduction device - hearing outcomes and safety in 38 patients [J].
Vyskocil, E. ;
Riss, D. ;
Arnoldner, C. ;
Hamzavi, J. S. ;
Liepins, R. ;
Kaider, A. ;
Honeder, C. ;
Fumicz, J. ;
Gstoettner, W. ;
Baumgartner, W. D. .
CLINICAL OTOLARYNGOLOGY, 2017, 42 (05) :1033-1038
[16]   Outcome prediction for Bonebridge candidates based on audiological indication criteria [J].
Wimmer, Wilhelm ;
von Werdt, Moritz ;
Mantokoudis, Georgios ;
Anschuetz, Lukas ;
Kompis, Martin ;
Caversaccio, Marco .
AURIS NASUS LARYNX, 2019, 46 (05) :681-686