摘要
The advent of dynamic radiotherapy modeling and treatment techniques requires an infrastructure to weigh the merits of various interventions (breath holding, gating, tracking). The creation of treatment planning models that account for motion and deformation can allow the relative worth of such techniques to be evaluated. In order to develop a treatment planning model of a moving and deforming organ such as the lung, registration tools that account for deformation are required. We tested the accuracy of a mutual information based image registration tool using thin-plate splines driven by the selection of control points and iterative alignment according to a simplex algorithm. Eleven patients each had sequential CT scans at breath-held normal inhale and exhale states. The exhale right lung was segmented from CT and served as the reference model. For each patient, thirty control points were used to align the inhale CT right lung to the exhale CT right lung. Alignment accuracy (the standard deviation of the difference in the actual and predicted inhale position) was determined from locations of vascular and bronchial bifurcations, and found to be 1.7, 3.1, and 3.6 mm about the RL, AP, and IS directions. The alignment accuracy was significantly different from the amount of measured movement during breathing only in the AP and IS directions. The accuracy of alignment including thin-plate splines was more accurate than using affine transformations and the same iteration and scoring methodology. This technique shows promise for the future development of dynamic models of the lung for use in four-dimensional (4-D) treatment planning. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:2942 / 2948
页数:7
相关论文
共 26 条
  • [1] [Anonymous], 1998, 62 ICRU
  • [2] Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing
    Balter, JM
    TenHaken, RK
    Lawrence, TS
    Lam, KL
    Robertson, JM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01): : 167 - 174
  • [3] A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error
    Beckham, WA
    Keall, PJ
    Siebers, JV
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (19) : 3465 - 3473
  • [4] Brock KK, 2003, MED PHYS, V30, P1330
  • [5] Inclusion of organ deformation in dose calculations
    Brock, KK
    McShan, DL
    Ten Haken, RK
    Hollister, SJ
    Dawson, LA
    Balter, JM
    [J]. MEDICAL PHYSICS, 2003, 30 (03) : 290 - 295
  • [6] Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patients
    Chen, QS
    Weinhous, MS
    Deibel, FC
    Ciezki, JP
    Macklis, RM
    [J]. MEDICAL PHYSICS, 2001, 28 (09) : 1850 - 1856
  • [7] A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study
    Chetty, IJ
    Rosu, M
    Tyagi, N
    Marsh, LH
    McShan, DL
    Balter, JM
    Fraass, BA
    Ten Haken, RK
    [J]. MEDICAL PHYSICS, 2003, 30 (07) : 1776 - 1780
  • [8] Image-based dose planning of intracavitary brachytherapy: Registration of serial-imaging studies using deformable anatomic templates
    Christensen, GE
    Carlson, B
    Chao, KSC
    Yin, P
    Grigsby, PW
    Nguyen, K
    Dempsey, JF
    Lerma, FA
    Bae, KT
    Vannier, MW
    Williamson, JF
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (01): : 227 - 243
  • [9] Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. I. The effect of shift invariance
    Craig, T
    Battista, J
    Van Dyk, J
    [J]. MEDICAL PHYSICS, 2003, 30 (08) : 2001 - 2011
  • [10] Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. II. The effect of a finite number of fractions
    Craig, T
    Battista, J
    Van Dyk, J
    [J]. MEDICAL PHYSICS, 2003, 30 (08) : 2012 - 2020