Behaviour and strength of back-to-back built-up cold-formed steel unequal angle sections with intermediate stiffeners under axial compression

被引:21
|
作者
Ananthi, G. Beulah Gnana [1 ]
Roy, Krishanu [1 ,2 ]
Lim, James B. P. [1 ,2 ]
机构
[1] Anna Univ, Div Struct Engn, Coll Engn, Guindy Campus, Chennai, Tamil Nadu, India
[2] Univ Auckland, Dept Civil & Environm Engn, Auckland, New Zealand
来源
STEEL AND COMPOSITE STRUCTURES | 2022年 / 42卷 / 01期
关键词
axial strength; back-to-back built-up sections; buckling; cold-formed steel; finite element modelling; stiffened unequal angle sections; CHANNEL SECTIONS; NONLINEAR BEHAVIOR; NUMERICAL INVESTIGATIONS; BUCKLING BEHAVIOR; CAPACITY; DESIGN; COLUMNS; TESTS; EDGE; SINGLE;
D O I
10.12989/scs.2022.42.1.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In cold-formed steel (CFS) structures, such as trusses, transmission towers and portal frames, the use of back-toback built-up CFS unequal angle sections are becoming increasingly popular. In such an arrangement, intermediate welds or screw fasteners are required at discrete points along the length, preventing the angle sections from buckling independently. Limited research is available in the literature on axial strength of back-to-back built-up CFS unequal angle sections. The issue is addressed herein. This paper presents an experimental investigation reported by the authors on back-to-back built-up CFS unequal angle sections with intermediate stiffeners under axial compression. The load-axial shortening behaviour along with the deformed shapes at failure are reported. A nonlinear finite element (FE) model was then developed, which includes material non-linearity, geometric imperfections and modelling of intermediate fasteners. The FE model was validated against the experimental test results, which showed good agreement, both in terms of failure loads and deformed shapes at failure. The validated finite element model was then used for the purpose of a parametric study comprising 96 models to investigate the effect of longer to shorter leg ratios, stiffener provided in the longer leg, thicknesses and lengths on axial strength of back-toback built-up CFS unequal angle sections. Four different thicknesses and seven different lengths (stub to slender columns) with three overall widths to the overall depth (B/D) ratios were investigated in the parametric study. Axial strengths obtained from the experimental tests and FE analyses were used to assess the performance of the current design guidelines as per the Direct Strength Method (DSM); obtained comparisons show that the current DSM is conservative by only 7% and 5% on average, while predicting the axial strengths of back-to-back built-up CFS unequal angle sections with and without the stiffener, respectively.
引用
收藏
页码:1 / 22
页数:22
相关论文
共 50 条
  • [21] Structural behaviour of back-to-back cold-formed steel channel sections with web openings under axial compression at elevated temperatures
    Fang, Zhiyuan
    Roy, Krishanu
    Lakshmanan, Dinesh
    Pranomrum, Pom
    Li, Frank
    Lau, Hieng Ho
    Lim, James B. P.
    JOURNAL OF BUILDING ENGINEERING, 2022, 54
  • [22] Effect of thickness on the behaviour of axially loaded back-to-back cold-formed steel built-up channel sections - Experimental and numerical investigation
    Roy, Krishanu
    Ting, Tina Chui Huon
    Lau, Hieng Ho
    Lim, James B. P.
    STRUCTURES, 2018, 16 : 327 - 346
  • [23] A NUMERICAL INVESTIGATION ON COLD-FORMED STEEL BUILT-UP BACK-TO-BACK CHANNEL STUB COLUMNS
    Ting, T. C. H.
    Lau, H. H.
    Proceedings of the 7th International Conference on Steel and Aluminium Structures (ICSAS 2011), 2011, : 443 - 449
  • [24] COMPRESSION TESTS OF COLD-FORMED STEEL BUILT-UP CLOSED SECTIONS WITH WEB STIFFENERS
    Zhang, Jia-Hui
    Young, Ben
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [25] Effect of screw spacing on behavior of axially loaded back-to-back cold-formed steel built-up channel sections
    Ting, Tina Chui Huon
    Roy, Krishanu
    Lau, Hieng Ho
    Lim, James B. P.
    ADVANCES IN STRUCTURAL ENGINEERING, 2018, 21 (03) : 474 - 487
  • [26] Numerical study on bending resistance of cold-formed steel back-to-back built-up elements
    Lukačević, Ivan
    Ungureanu, Viorel
    Valčić, Anđelo
    Ćurković, Ivan
    ce/papers, 2021, 4 (2-4) : 487 - 494
  • [27] DSM design of fixed-ended slender built-up back-to-back cold-formed steel compression members
    Son Tung Vy
    Mahendran, Mahen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 189
  • [28] Behaviour of stiffened cold-formed steel built-up sections with complex edge stiffeners under bending
    P. Manikandan
    S. Sukumar
    KSCE Journal of Civil Engineering, 2015, 19 : 2108 - 2115
  • [29] Behaviour of stiffened cold-formed steel built-up sections with complex edge stiffeners under bending
    Manikandan, P.
    Sukumar, S.
    KSCE JOURNAL OF CIVIL ENGINEERING, 2015, 19 (07) : 2108 - 2115
  • [30] Flexural behaviour of back-to-back built-up cold-formed steel channel beams: Experiments and finite element modelling
    Roy, Krishanu
    Lau, Hieng Ho
    Ting, Tina Chui Huon
    Chen, Boshan
    Lim, James B. P.
    STRUCTURES, 2021, 29 : 235 - 253