Behaviour and strength of back-to-back built-up cold-formed steel unequal angle sections with intermediate stiffeners under axial compression

被引:21
|
作者
Ananthi, G. Beulah Gnana [1 ]
Roy, Krishanu [1 ,2 ]
Lim, James B. P. [1 ,2 ]
机构
[1] Anna Univ, Div Struct Engn, Coll Engn, Guindy Campus, Chennai, Tamil Nadu, India
[2] Univ Auckland, Dept Civil & Environm Engn, Auckland, New Zealand
来源
STEEL AND COMPOSITE STRUCTURES | 2022年 / 42卷 / 01期
关键词
axial strength; back-to-back built-up sections; buckling; cold-formed steel; finite element modelling; stiffened unequal angle sections; CHANNEL SECTIONS; NONLINEAR BEHAVIOR; NUMERICAL INVESTIGATIONS; BUCKLING BEHAVIOR; CAPACITY; DESIGN; COLUMNS; TESTS; EDGE; SINGLE;
D O I
10.12989/scs.2022.42.1.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In cold-formed steel (CFS) structures, such as trusses, transmission towers and portal frames, the use of back-toback built-up CFS unequal angle sections are becoming increasingly popular. In such an arrangement, intermediate welds or screw fasteners are required at discrete points along the length, preventing the angle sections from buckling independently. Limited research is available in the literature on axial strength of back-to-back built-up CFS unequal angle sections. The issue is addressed herein. This paper presents an experimental investigation reported by the authors on back-to-back built-up CFS unequal angle sections with intermediate stiffeners under axial compression. The load-axial shortening behaviour along with the deformed shapes at failure are reported. A nonlinear finite element (FE) model was then developed, which includes material non-linearity, geometric imperfections and modelling of intermediate fasteners. The FE model was validated against the experimental test results, which showed good agreement, both in terms of failure loads and deformed shapes at failure. The validated finite element model was then used for the purpose of a parametric study comprising 96 models to investigate the effect of longer to shorter leg ratios, stiffener provided in the longer leg, thicknesses and lengths on axial strength of back-toback built-up CFS unequal angle sections. Four different thicknesses and seven different lengths (stub to slender columns) with three overall widths to the overall depth (B/D) ratios were investigated in the parametric study. Axial strengths obtained from the experimental tests and FE analyses were used to assess the performance of the current design guidelines as per the Direct Strength Method (DSM); obtained comparisons show that the current DSM is conservative by only 7% and 5% on average, while predicting the axial strengths of back-to-back built-up CFS unequal angle sections with and without the stiffener, respectively.
引用
收藏
页码:1 / 22
页数:22
相关论文
共 50 条
  • [1] Influence of intermediate stiffeners on the axial capacity of cold-formed steel back-to-back built-up unequal angle sections
    Ananthi, G. Beulah Gnana
    Deepak, M. S.
    Roy, Krishanu
    Lim, James B. P.
    STRUCTURES, 2021, 32 : 827 - 848
  • [2] Testing, simulation and design of back-to-back built-up cold-formed steel unequal angle sections under axial compression
    Ananthi, G. Beulah Gnana
    Roy, Krishanu
    Chen, Boshan
    Lim, James Bp
    STEEL AND COMPOSITE STRUCTURES, 2019, 33 (04): : 595 - 614
  • [3] Nonlinear behaviour of back-to-back gapped built-up cold-formed steel channel sections under compression
    Roy, Krishanu
    Ting, Tina Chui Huon
    Lau, Hieng Ho
    Lim, James B. P.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 147 : 257 - 276
  • [4] Experimental and numerical investigations on axial strength of back-to-back built-up cold-formed steel angle columns
    Ananthi, G. Beulah Gnana
    Roy, Krishanu
    Lim, James B. P.
    STEEL AND COMPOSITE STRUCTURES, 2019, 31 (06): : 601 - 615
  • [5] Simulation of screw connected built-up cold-formed steel back-to-back lipped channels under axial compression
    Kechidi, Smail
    Fratamico, David C.
    Schafer, Benjamin W.
    Castro, Jose Miguel
    Bourahla, Nouredine
    ENGINEERING STRUCTURES, 2020, 206
  • [6] Finite element modelling of back back-to-back built built-up cold cold-formed stainless-steel lipped channels under axial compression
    Roy K.
    Lau H.H.
    Lim J.B.P.
    Steel and Composite Structures, 2019, 33 (01): : 869 - 898
  • [7] Cold-formed steel built-up closed sections with intermediate stiffeners
    Young, Ben
    Chen, Ju
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL, SPACE & COMPOSITE STRUCTURES, 2007, : 43 - +
  • [8] Compression Test on Cold-Formed Steel Built-up Back-to-Back Channels Stub Columns
    Ting, Chui Huon Tina
    Lau, Hieng Ho
    ADVANCED MANUFACTURING SYSTEMS, PTS 1-3, 2011, 201-203 : 2900 - 2903
  • [9] Design of Cold-Formed Steel Back-To-Back Connected Built-up Beams
    Selvaraj, Sivaganesh
    Madhavan, Mahendrakumar
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 181
  • [10] Finite element modelling of back-to-back built-up cold-formed stainless-steel lipped channels under axial compression
    Roy, Krishanu
    Lau, Hieng Ho
    Lim, James B. P.
    STEEL AND COMPOSITE STRUCTURES, 2019, 33 (01): : 37 - 66