Exposure to the mixtures of organic compounds in homes in Japan

被引:36
作者
Park, JS
Ikeda, K
机构
[1] Hanyang Univ, Coll Architecture, Div Architectural Engn, Seoul 133791, South Korea
[2] Natl Inst Publ Hlth, Dept Architectural Hyg Engn & Housing, Tokyo, Japan
关键词
Aldehydes; volatile organic compounds; Exposure; Statistical distribution; Joint probability distribution;
D O I
10.1111/j.1600-0668.2004.00266.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The aim of the study reported herein was to characterize occupants' simultaneous exposure to mixtures of organic compounds in homes. Statistical distributions for concentrations of 28 organic compounds (17 VOCs and 11 aldehydes) measured in 1417 homes were generated to analyze concentration distributions. Three candidate distributions were identified for fitting the measured data: log-normal, exponential and gamma distributions. It appears from the results of fitting tests that gamma distributions are capable of representing 28 compound concentrations. Probability distributions show that formaldehyde and acetaldehyde ranged from 25 to 220 mug/m(3) at 90% probabilities and most VOCs ranged from 3 to 80 mug/m(3) at 90% probabilities. In order to characterize the occupant's exposure to the mixtures, the joint probability distributions of organic compounds were generated from the best-fitted distributions of individual compounds under the assumption that concentrations of organic compounds are mutually independent in homes. These joint distributions provided the statistical data for characterizing the occupant's exposure to the mixtures of organic compounds in homes.
引用
收藏
页码:413 / 420
页数:8
相关论文
共 11 条
  • [1] FREQUENCY-DISTRIBUTIONS OF AIR POLLUTANT CONCENTRATIONS
    BENCALA, KE
    SEINFELD, JH
    [J]. ATMOSPHERIC ENVIRONMENT, 1976, 10 (11) : 941 - 950
  • [2] BROWN VM, 1999, 8 INT C IND AIR QUAL, V4, P95
  • [3] DAVID AO, 1992, ARCH ENVIRON HEALTH, V47, P23
  • [4] Impact of temperature and humidity on chemical and sensory emissions from building materials
    Fang, L
    Clausen, G
    Fanger, PO
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (03): : 193 - 201
  • [5] FUJII S, 1997, J ARCHITECTURE PLANN, V500, P65
  • [6] Fujii S., 2000, J ARCH PLANN ENV ENG, V536, P49
  • [7] PARK JS, 1996, 7 INT C IND AIR QUAL, V3, P579
  • [8] PARK JS, 1998, J ARCHITECTURE PLANN, V509, P27
  • [9] Voltage-gated sodium channel genes hscp and hDSC1 of Heliothis virescens F-genomic organization
    Park, Y
    Taylor, MFJ
    Feyereisen, R
    [J]. INSECT MOLECULAR BIOLOGY, 1999, 8 (02) : 161 - 170
  • [10] TANABE S, 1999, 8 INT C IND AIR QUAL, V5, P117