Further Analysis of the Predictability of Corneal Endothelial Cell Density Estimates When Polymegethism Is Present

被引:3
作者
Doughty, Michael J. [1 ]
机构
[1] Glasgow Caledonian Univ, Dept Vis Sci, Cowcaddens Rd, Glasgow G4 OBA, Lanark, Scotland
关键词
cornea; endothelium; human; polymegethism; ECD estimates; cell counts; NONCONTACT SPECULAR MICROSCOPE; QUANTITATIVE-ANALYSIS; RELIABILITY; MORPHOLOGY; AGE;
D O I
10.1097/ICO.0000000000001218
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess variability in endothelial cell density (ECD) estimates when polymegethism (variance in cell areas) is present. Methods: Using noncontact specular microscope images of the corneal endothelium, 4 sets of 20 cases were selected, which included 200 cells and had coefficient of variation values of less than 30% (group 1), 31%-40% (group 2), 41%-50% (group 3), and over 50% (group 4). A stepwise analysis was undertaken, 20 cells at a time, of the ECD estimates when using different numbers of cells for the calculations. Results: The net differences in ECD estimates when comparing sets of 20 cells with 200 cells were 5.0% +/- 3.9%, 8.1% +/- 7.3%, 11.3% +/- 9.4%, and 14.5% +/- 12.4% for groups 1 to 4, respectively. For measures on 100 cells per image, the predicted variances in ECD values were 5.6%, 8.8%, 11.1%, and 13.7% for the 4 groups. Conclusions: Higher values of corneal endothelial polymegethism result in predictable increases in the variability (uncertainty) in ECD estimates, thus reducing the "accuracy" of ECD values. There is no obvious utility in assessing more than 100 cells in such endothelia.
引用
收藏
页码:973 / 979
页数:7
相关论文
共 25 条
  • [1] The Sampling Error From Specular Microscopy Examinations and Their Reliability Indexes
    Abib, Fernando C.
    Costa, Adriana A.
    Haddad, Celso P.
    Abib, Dulcemar S.
    Neto, Jose Luiz A.
    [J]. CORNEA, 2013, 32 (03) : 377 - 378
  • [2] The Endothelial Sample Size Analysis in Corneal Specular Microscopy Clinical Examinations
    Abib, Fernando C.
    Holzchuh, Ricardo
    Schaefer, Artur
    Schaefer, Tania
    Godois, Ronialci
    [J]. CORNEA, 2012, 31 (05) : 546 - 550
  • [3] [Anonymous], 2015, J MED SCI CLIN RES
  • [4] Cell-by-Cell Alignment of Repeated Specular Microscopy Images from the Same Eye
    Boehringer, Daniel
    Lang, Stefan
    Reinhard, Thomas
    [J]. PLOS ONE, 2013, 8 (03):
  • [5] VARIATIONS IN HUMAN CORNEAL ENDOTHELIAL-CELL MORPHOLOGY AND PERMEABILITY TO FLUORESCEIN WITH AGE
    CARLSON, KH
    BOURNE, WM
    MCLAREN, JW
    BRUBAKER, RF
    [J]. EXPERIMENTAL EYE RESEARCH, 1988, 47 (01) : 27 - 41
  • [6] Using of Cells Analyser® software in the study of image of corneal specular microscope endothelial samples
    de Melo, Cinthia Mendonca
    dos Santos, Procopio Miguel
    Ribeiro dos Santos, Regina Candido
    Abib, Fernando Cesar
    [J]. ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2008, 71 (01) : 79 - 82
  • [7] Corneal Changes in Diabetic Patients after Manual Small Incision Cataract Surgery
    Dhasmana, Renu
    Singh, I. P.
    Nagpal, Ramesh C.
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2014, 8 (04) : VC3 - VC6
  • [8] Doughty MJ, 2013, OCULAR SURFACE: ANATOMY AND PHYSIOLOGY, DISORDERS AND THERAPEUTIC CARE, P32
  • [9] A prospective analysis of corneal endothelial polymegethism and cell density in young adult Asians
    Doughty, Michael J.
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2014, 97 (03) : 256 - 263
  • [10] Evaluation of Possible Error Sources in Corneal Endothelial Morphometry With a Semiautomated Noncontact Specular Microscope
    Doughty, Michael J.
    [J]. CORNEA, 2013, 32 (09) : 1196 - 1203