Active Suppression Method of Dangerous Behaviors for Robot-Assisted Vascular Interventional Surgery

被引:22
|
作者
Jin, Xiaoliang [1 ,2 ]
Guo, Shuxiang [1 ,3 ]
Guo, Jian [4 ]
Shi, Peng [1 ,2 ]
Kawanishi, Masahiko [5 ]
Hirata, Hideyuki [6 ]
机构
[1] Beijing Inst Technol, Key Lab Convergence Med Engn Syst & Healthcare Te, Minist Ind & Informat Technol, Beijing 100081, Peoples R China
[2] Kagawa Univ, Grad Sch Engn, Takamatsu, Kagawa 7610396, Japan
[3] Kagawa Univ, Dept Intelligent Mech Syst Engn, Fac Engn & Design, Takamatsu, Kagawa 7610396, Japan
[4] Tianjin Univ Technol, Tianjin Key Lab Controlory & Applicat Complicated, Tianjin 300384, Peoples R China
[5] Kagawa Univ, Dept Neurol Surg, Fac Med, Takamatsu, Kagawa 7610793, Japan
[6] Kagawa Univ, Dept Intelligent Mech Syst Engn, Takamatsu, Kagawa 7610396, Japan
基金
中国国家自然科学基金; 日本学术振兴会;
关键词
Medical services; Force; Catheters; Robots; Manipulators; Safety; Surgery; Active enhancing safety method; active suppression method; collision force; flexible instruments; haptic force feedback; robot-assisted vascular interventional surgery (VIS); GUIDEWIRE; CATHETER; FRAMEWORK; FEEDBACK; SYSTEM;
D O I
10.1109/TIM.2022.3170997
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The procedure of vascular interventional surgery (VIS) is very complicated. It requires doctors to wear the protecting suits and manipulate the flexible instruments (catheters and guidewires) for a long time to complete the treatment, which may fatigue the doctors and lead to misoperation. Besides, the X-ray radiation in the operating room is also bad for doctors' health. So, to solve the above challenges, a novel robot-assisted system was developed for VIS, which realizes the separation of the doctor and the operating room; a preliminary method was used on the slave side to reduce the excessive collision force when the tip of the catheter travels through the curved blood vessel, and the active enhancing safety method of the robot-assisted system was proposed to reduce the danger caused by doctors' misoperation (dangerous behaviors) during the surgery. Finally, to verify the proposed methods, a series of experiments in vitro were conducted, and experimental results indicated that the method of assisting the deflection of the tip of the catheter has the potential to reduce the excessive collision force, the collision force at the tip of the catheter was reduced by 0.104 N when a misoperation occurred during the operation procedure under the condition of the active enhancing safety method, and the stronger sense of the tactile presence was generated by the master manipulator when the total force of the slave side was greater than 1.0 N. Therefore, based on the above results, we believe that the proposed methods are effective.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] The end of robot-assisted laparoscopy? A critical appraisal of scientific evidence on the use of robot-assisted laparoscopic surgery
    Jeroen Heemskerk
    Nicole D. Bouvy
    Cor G. M. I. Baeten
    Surgical Endoscopy, 2014, 28 : 1388 - 1398
  • [32] A Novel Catheter Operating Robot for Vascular Interventional Surgery
    Meng, Cai
    Guan, Shaoya
    Sun, Shengnan
    Liu, Yin
    Wang, Tianmiao
    2016 IEEE WORKSHOP ON ADVANCED ROBOTICS AND ITS SOCIAL IMPACTS (ARSO), 2016, : 304 - 309
  • [33] Remote-controlled vascular interventional surgery robot
    Wang, Tianmiao
    Zhang, Dapeng
    Da, Liu
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2010, 6 (02): : 194 - 201
  • [34] A Novel Vascular Interventional Robot for Cardiac Ablation Surgery
    Zuo, Jinshan
    Zhang, Linshuai
    Hao, Xinlin
    Yang, Yang
    Zhang, Xinyu
    Jiang, Tao
    2024 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, ICMA 2024, 2024, : 245 - 250
  • [35] Advances in Robot-Assisted Surgery for Facial Bone Contouring Surgery
    Lin, Li
    Zhao, Zhijie
    Han, Wenqing
    Sun, Mengzhe
    Zhang, Ziwei
    Kim, Byeong Seop
    Yan, Yingjie
    Chen, Xiaojun
    Aung, Zin Mar
    Liu, Xiangqi
    Wang, Xuetong
    Li, Xing
    Yang, Xianxian
    Wang, Bingshun
    Xu, Haisong
    Chai, Gang
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (02) : 813 - 816
  • [36] Deep Learning Based Tremor Signal Recognition Method for a Vascular Interventional Surgery Robot
    Luo, Jintao
    Guo, Shuxiang
    Yan, Yonggan
    Zhao, Duohao
    Lyu, Chuqiao
    Lin, Zhijun
    Wang, Bin
    Ding, Mingchao
    2024 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, ICMA 2024, 2024, : 561 - 566
  • [37] Tissue Property Estimation and Graphical Display for Teleoperated Robot-Assisted Surgery
    Yamamoto, Tomonori
    Vagvolgyi, Balazs
    Balaji, Kamini
    Whitcomb, Louis L.
    Okamura, Allison M.
    ICRA: 2009 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-7, 2009, : 3117 - 3123
  • [38] Adaptive Control Improves Sclera Force Safety in Robot-Assisted Eye Surgery: A Clinical Study
    Ebrahimi, Ali
    Urias, Mueller G.
    Patel, Niravkumar
    Taylor, Russell H.
    Gehlbach, Peter
    Iordachita, Iulian
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (11) : 3356 - 3365
  • [39] Robot-assisted Active Catheter Insertion: Algorithms and Experiments
    Jayender, J.
    Patel, R. V.
    Nikumb, S.
    INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2009, 28 (09): : 1101 - 1117
  • [40] Endoscope FOV Autonomous Tracking Method for Robot-Assisted Surgery Considering Pose Control, Hand-Eye Coordination, and Image Definition
    Peng, Jianqing
    Zhang, Chi
    Kang, Liang
    Feng, Guodong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71