Active Suppression Method of Dangerous Behaviors for Robot-Assisted Vascular Interventional Surgery

被引:22
|
作者
Jin, Xiaoliang [1 ,2 ]
Guo, Shuxiang [1 ,3 ]
Guo, Jian [4 ]
Shi, Peng [1 ,2 ]
Kawanishi, Masahiko [5 ]
Hirata, Hideyuki [6 ]
机构
[1] Beijing Inst Technol, Key Lab Convergence Med Engn Syst & Healthcare Te, Minist Ind & Informat Technol, Beijing 100081, Peoples R China
[2] Kagawa Univ, Grad Sch Engn, Takamatsu, Kagawa 7610396, Japan
[3] Kagawa Univ, Dept Intelligent Mech Syst Engn, Fac Engn & Design, Takamatsu, Kagawa 7610396, Japan
[4] Tianjin Univ Technol, Tianjin Key Lab Controlory & Applicat Complicated, Tianjin 300384, Peoples R China
[5] Kagawa Univ, Dept Neurol Surg, Fac Med, Takamatsu, Kagawa 7610793, Japan
[6] Kagawa Univ, Dept Intelligent Mech Syst Engn, Takamatsu, Kagawa 7610396, Japan
基金
中国国家自然科学基金; 日本学术振兴会;
关键词
Medical services; Force; Catheters; Robots; Manipulators; Safety; Surgery; Active enhancing safety method; active suppression method; collision force; flexible instruments; haptic force feedback; robot-assisted vascular interventional surgery (VIS); GUIDEWIRE; CATHETER; FRAMEWORK; FEEDBACK; SYSTEM;
D O I
10.1109/TIM.2022.3170997
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The procedure of vascular interventional surgery (VIS) is very complicated. It requires doctors to wear the protecting suits and manipulate the flexible instruments (catheters and guidewires) for a long time to complete the treatment, which may fatigue the doctors and lead to misoperation. Besides, the X-ray radiation in the operating room is also bad for doctors' health. So, to solve the above challenges, a novel robot-assisted system was developed for VIS, which realizes the separation of the doctor and the operating room; a preliminary method was used on the slave side to reduce the excessive collision force when the tip of the catheter travels through the curved blood vessel, and the active enhancing safety method of the robot-assisted system was proposed to reduce the danger caused by doctors' misoperation (dangerous behaviors) during the surgery. Finally, to verify the proposed methods, a series of experiments in vitro were conducted, and experimental results indicated that the method of assisting the deflection of the tip of the catheter has the potential to reduce the excessive collision force, the collision force at the tip of the catheter was reduced by 0.104 N when a misoperation occurred during the operation procedure under the condition of the active enhancing safety method, and the stronger sense of the tactile presence was generated by the master manipulator when the total force of the slave side was greater than 1.0 N. Therefore, based on the above results, we believe that the proposed methods are effective.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] A Robot-Assisted Surgery Positioning Method for Artificial Cervical Disc Replacement
    Tian, Heqiang
    Wu, Dongmei
    Du, Zhijiang
    Sun, Lining
    MEMS, NANO AND SMART SYSTEMS, PTS 1-6, 2012, 403-408 : 3009 - 3014
  • [22] A Stability and Safety Control Method in Robot-Assisted Decompressive Laminectomy Considering Respiration and Deformation of Spine
    Li, Meng
    Qi, Xiaozhi
    Sun, Yu
    Li, Bing
    Hu, Ying
    Tian, Wei
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2023, 20 (01) : 258 - 270
  • [23] A Proximal Push Force-based Force Feedback Algorithm for Robot-assisted Vascular Intervention Surgery
    Qin, Mingyang
    Xiao, Nan
    Guo, Shuxiang
    Guo, Ping
    Wang, Yuan
    2015 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2015, : 738 - 742
  • [24] Exploring the Limitations and Implications of the JIGSAWS Dataset for Robot-Assisted Surgery
    Hendricks, Antonio
    Panoff, Max
    Xiao, Kaiwen
    Wang, Zhaoqi
    Wang, Shuo
    Bobda, Christophe
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2024, 9 (11): : 9534 - 9541
  • [25] Feasibility study on robot-assisted retinal vascular bypass surgery in an exvivo porcine model
    Chen, Yi Qi
    Tao, Ji Wei
    Li, Liang
    Mao, Jian Bo
    Zhu, Chen Ting
    Lao, Ji Meng
    Yang, Yang
    Shen, Li-Jun
    ACTA OPHTHALMOLOGICA, 2017, 95 (06) : E462 - E467
  • [26] Haptics for Robot-Assisted Minimally Invasive Surgery
    Okamura, A. M.
    Verner, L. N.
    Reiley, C. E.
    Mahvash, M.
    ROBOTICS RESEARCH, 2010, 66 : 361 - 372
  • [27] State of the Art in Robot-Assisted Eye Surgery
    Bourcier, Tristan
    Dormegny, Lea
    Sauer, Arnaud
    Nardin, Mathieu
    Becmeur, Pierre-Henri
    Chammas, Jimmy
    Gaucher, David
    Ballonzoli, Laurent
    Speeg, Claude
    Liverneaux, Philippe
    Vix, Michel
    Marescaux, Jacques
    Mutter, Didier
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2021, 238 (12) : 1290 - 1293
  • [28] Error Analysis of Robot-Assisted Orthognathic Surgery
    Wu, Jinyang
    Hui, Wenyu
    Chen, Shihang
    Niu, Jindong
    Lin, Yanping
    Luan, Nan
    Zhang, Shilei
    Shen, Steve G. F.
    JOURNAL OF CRANIOFACIAL SURGERY, 2020, 31 (08) : 2324 - 2328
  • [29] Intra-operative tumour localisation in robot-assisted minimally invasive surgery: A review
    Li, Min
    Liu, Hongbin
    Jiang, Allen
    Seneviratne, Lakmal D.
    Dasgupta, Prokar
    Althoefer, Kaspar
    Wurdemann, Helge
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (05) : 509 - 522
  • [30] The end of robot-assisted laparoscopy? A critical appraisal of scientific evidence on the use of robot-assisted laparoscopic surgery
    Heemskerk, Jeroen
    Bouvy, Nicole D.
    Baeten, Cor G. M. I.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2014, 28 (04): : 1388 - 1398