Reducing inappropriate arterial blood gas testing in a level III intensive care unit: a before-and-after observational study

被引:0
作者
Walsh, Oliver M. [1 ,2 ]
Davis, Katelyn [3 ]
Gatward, Jonathan [3 ,4 ]
机构
[1] Canberra Hosp, Canberra, ACT, Australia
[2] Australian Natl Univ, Canberra, ACT, Australia
[3] Royal North Shore Hosp, Sydney, NSW, Australia
[4] Univ Sydney, Sydney, NSW, Australia
关键词
CRITICALLY-ILL; TRANSFUSION; GUIDELINE; ANEMIA; INTERVENTION; LINES;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Arterial blood gas (ABG) analysis is the most frequently performed test in intensive care units (ICUs), often without a specific clinical indication. This is costly and contributes to iatrogenic anaemia. Objectives: To reduce the number of ABG tests performed and the proportion that are inappropriate. Design, setting and participants: The indications for ABG analysis were surveyed at a 58-bed level III ICU during fortnightly periods before and after a multifaceted educational intervention which included the introduction of a clinical guideline. The number of ABG tests performed during the period July-December 2017 was compared with that for the period July-December 2018. Tests were predefined as inappropriate if performed at regular time intervals, at change of shift, concurrently with other blood tests or after a treatment was ceased on a stable patient or after ventilatory support or oxygen delivery was decreased in an otherwise stable patient. The study was enrolled on the Quality Improvement Projects Register and ethics approval was waived by the local ethics committee. Results: There was a 31.3% bed-day adjusted decrease in number of ABG tests performed (33 005 v 22 408; P < 0.001), representing an annual saving of A$770 000 and 100 litres of blood. The proportion of inappropriate ABG tests decreased by 47.3% (54.2% v 28.6%; P < 0.001) and the number of inappropriate ABG tests per bed-day decreased by 71% (2.8 v 0.8; P < 0.001). Patient outcomes before and after the intervention did not differ (standardised mortality ratio, 0.65 v 0.63; P = 0.22). Conclusion: Staff education and implementation of a clinical guideline resulted in substantial decreases in the number of ABG tests performed and the proportion of inappropriate ABG tests.
引用
收藏
页码:370 / 377
页数:8
相关论文
共 30 条
[1]   Blood gas analysis: a study of blood loss in intensive care [J].
Andrews, T ;
Waterman, H ;
Hillier, V .
JOURNAL OF ADVANCED NURSING, 1999, 30 (04) :851-857
[2]   Choosing Wisely® in Critical Care: Maximizing Value in the Intensive Care Unit [J].
Angus, Derek C. ;
Deutschman, Clifford S. ;
Hall, Jesse B. ;
Wilson, Kevin C. ;
Munro, Cindy L. ;
Hill, Nicholas S. .
CRITICAL CARE MEDICINE, 2014, 42 (11) :2437-2438
[3]  
[Anonymous], 2017, Declined Detainer Outcome Report
[4]  
Astles T., 2009, J Intensive Care Soc, V10, P279, DOI DOI 10.1177/175114370901000413
[5]   Phlebotomy in the intensive care unit: strategies for blood conservation [J].
Barie, PS .
CRITICAL CARE, 2004, 8 (Suppl 2) :S34-S36
[6]   Reevaluation of the utilization of arterial blood gas analysis in the Intensive Care Unit: Effects on patient safety and patient outcome [J].
Blum, Franziska E. ;
Lund, Elisa Takalo ;
Hall, Heather A. ;
Tachauer, Allan D. ;
Chedrawy, Edgar G. ;
Zilberstein, Jeffrey .
JOURNAL OF CRITICAL CARE, 2015, 30 (02) :438-U277
[7]  
BROWNING J A, 1989, Respiratory Care, V34, P269
[8]  
College of Intensive Care Medicine of Australia and New Zealand, CHOOS WISELY
[9]   RBC TRANSFUSION IN THE ICU - IS THERE A REASON [J].
CORWIN, HL ;
PARSONNET, KC ;
GETTINGER, A .
CHEST, 1995, 108 (03) :767-771
[10]   The CRIT Study: Anemia and blood transfusion in the critically ill - Current clinical practice in the United States [J].
Corwin, HL ;
Gettinger, A ;
Pearl, RG ;
Fink, MP ;
Levy, MM ;
Abraham, E ;
MacIntyre, NR ;
Shabot, M ;
Duh, MS ;
Shapiro, MJ .
CRITICAL CARE MEDICINE, 2004, 32 (01) :39-52