Robustness in pig fat NIRS calibrations by orthogonal projection

被引:11
作者
Perez-Marin, D. [1 ]
Fearn, T. [2 ]
Guerrero, J. E. [1 ]
Garrido-Varo, A. [1 ]
机构
[1] Univ Cordoba, Dept Anim Prod, E-14071 Cordoba, Spain
[2] UCL, Dept Stat Sci, London WC1E 6BT, England
关键词
NIRS; Iberian pork fat; Fatty acids; Calibrations; Orthogonal projection; Robustness; SPECTRA;
D O I
10.1016/j.chemolab.2009.10.003
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The aim Of this Study was to evaluate the performance of the TOP (transfer by orthogonal projection) algorithm for minimising sources of variation that May Cause inaccurate predictions of fatty acids in the MRS analysis of pig fat. A calibration set of 188 samples of Iberian pork fat and two validation sets with 12 and 60 samples were analysed in a NIR (Near Infrared Reflectance) monochromator, using folded-transmission cups. Four correction files, all based on repeated measurement over time of a reference sample of pork fat, were tested for the application of the TOP algorithm. The results obtained for both validation sets showed that the use of TOP improved the robustness of the calibrations developed, reducing the SEP to values closer to the SECV of the calibrations for the four fatty acids measured, i.e. from 1.95% to 0.34% for palmitic, from 0.47% to 0.31% for stearic, from 0.53% to 0.39% for oleic and from 4.45% to 0.58% for linoleic, using the second validation set (n = 60), while the SECV is hardly affected by the application of TOP. These results suggest that TOP algorithm could be a useful and efficient tool for the improvement of liquid MRS calibrations. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:36 / 40
页数:5
相关论文
共 18 条
  • [11] Naes T, 2002, A User-Friendly Guide to Multivariate Calibration and Classification
  • [12] Chemometric utilities to achieve robustness in liquid NIRS calibrations:: Application to pig fat analysis
    Perez-Marin, D.
    Garrido-Varo, A.
    De Pedro, E.
    Guerrero-Ginel, J. E.
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2007, 87 (02) : 241 - 246
  • [13] Robust calibration using orthogonal projection and experimental design. Application to the correction of the light scattering effect on turbid NIR spectra
    Preys, S.
    Roger, J. M.
    BoUlet, J. C.
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2008, 91 (01) : 28 - 33
  • [14] Roberts C.A., 2004, Near-infrared spectroscopy in agriculture
  • [15] EPO-PLS external parameter orthogonalisation of PLS application to temperature-independent measurement of sugar content of intact fruits
    Roger, JM
    Chauchard, F
    Bellon-Maurel, V
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2003, 66 (02) : 191 - 204
  • [16] POPULATION STRUCTURING OF NEAR-INFRARED SPECTRA AND MODIFIED PARTIAL LEAST-SQUARES REGRESSION
    SHENK, JS
    WESTERHAUS, MO
    [J]. CROP SCIENCE, 1991, 31 (06) : 1548 - 1555
  • [17] Westerhaus M., 1990, Proc. 3rd Int. Conf. near Infrared Spectroscopy, P671
  • [18] Error removal by orthogonal subtraction (EROS): a customised pre-treatment for spectroscopic data
    Zhu, Ying
    Fearn, Tom
    Samuel, Douglas
    Dhar, Anjan
    Hameed, Omair
    Bown, Stephen G.
    Lovat, Laurence B.
    [J]. JOURNAL OF CHEMOMETRICS, 2008, 22 (1-2) : 130 - 134