Robustness in pig fat NIRS calibrations by orthogonal projection

被引:11
作者
Perez-Marin, D. [1 ]
Fearn, T. [2 ]
Guerrero, J. E. [1 ]
Garrido-Varo, A. [1 ]
机构
[1] Univ Cordoba, Dept Anim Prod, E-14071 Cordoba, Spain
[2] UCL, Dept Stat Sci, London WC1E 6BT, England
关键词
NIRS; Iberian pork fat; Fatty acids; Calibrations; Orthogonal projection; Robustness; SPECTRA;
D O I
10.1016/j.chemolab.2009.10.003
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The aim Of this Study was to evaluate the performance of the TOP (transfer by orthogonal projection) algorithm for minimising sources of variation that May Cause inaccurate predictions of fatty acids in the MRS analysis of pig fat. A calibration set of 188 samples of Iberian pork fat and two validation sets with 12 and 60 samples were analysed in a NIR (Near Infrared Reflectance) monochromator, using folded-transmission cups. Four correction files, all based on repeated measurement over time of a reference sample of pork fat, were tested for the application of the TOP algorithm. The results obtained for both validation sets showed that the use of TOP improved the robustness of the calibrations developed, reducing the SEP to values closer to the SECV of the calibrations for the four fatty acids measured, i.e. from 1.95% to 0.34% for palmitic, from 0.47% to 0.31% for stearic, from 0.53% to 0.39% for oleic and from 4.45% to 0.58% for linoleic, using the second validation set (n = 60), while the SECV is hardly affected by the application of TOP. These results suggest that TOP algorithm could be a useful and efficient tool for the improvement of liquid MRS calibrations. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:36 / 40
页数:5
相关论文
共 18 条
  • [1] Transfer by orthogonal projection: making near-infrared calibrations robust to between-instrument variation
    Andrew, A
    Fearn, T
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2004, 72 (01) : 51 - 56
  • [2] STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA
    BARNES, RJ
    DHANOA, MS
    LISTER, SJ
    [J]. APPLIED SPECTROSCOPY, 1989, 43 (05) : 772 - 777
  • [3] BURLINGCLARIDGE GR, 2007, NEAR INFR SPECTR P 1
  • [4] Davies A.M.C., 2004, P 11 INT C
  • [5] Microwave oven application in the extraction of fat from the subcutaneous tissue of Iberian pig ham
    DePedro, E
    Casillas, M
    Miranda, CM
    [J]. MEAT SCIENCE, 1997, 45 (01) : 45 - 51
  • [6] Fearn T., 2009, NIR news, V20, P24, DOI [DOI 10.1255/NIRN.1153, 10.1255/nirn.1153]
  • [7] Garrido-Varo A., 2004, Near-Infrared Spectroscopy in Agriculture, V44, P487, DOI [10.2134/agronmonogr44.c19, DOI 10.2134/AGRONMONOGR44.C19]
  • [8] GARRIDOVARO A, 2007, PRACTICAL SPECTROSCO, V35, P387
  • [9] Drift correction in multivariate calibration models using on-line reference measurements
    Gujral, Paman
    Amrhein, Michael
    Bonvin, Dominique
    [J]. ANALYTICA CHIMICA ACTA, 2009, 642 (1-2) : 27 - 36
  • [10] ISI, 2000, Manual FOSS NIRSystems. In the Complete Software Solution Using a Single Screen for Routine Analysis, Robust Calibrations, and Networking