A NOVEL METHOD FOR MOTION ARTIFACT REMOVAL IN WEARABLE PPG SENSORS BASED ON BLIND SOURCE SEPARATION

被引:0
|
作者
Pflugradt, Maik [1 ]
Rose, Marcus [1 ]
Orglmeister, Reinhold [1 ]
机构
[1] TU Berlin, Elect & Med Signal Proc, Berlin, Germany
关键词
Blind Source Separation; Motion Artifacts; Body Sensor Network; ANC; ICA;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The recent development of healthcare systems has provided a significant contribution to ambulatory patient monitoring. In that context, signal quality and disturbances induced by noise or motion artifacts play an important role in the field of signal processing tasks. Especially the Photoplethysmogram (PPG) is very liable to movement artifacts which severely hamper the extraction of vital parameters like the heart rate or oxygen saturation. To record patient movements, an innovative sensor system is proposed, which acquires accelerometer data next to the PPG. As in Adaptive Noise Cancelers, we propose to use the acceleration as reference to recover corrupted PPGs by means of the Blind Source Separation. Sophisticated methods of ICA have been used, resulting in a novel approach for artifact suppression in the PPG that has been tested on laboratory datasets.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] A Novel Blind Source Separation Method Based on the Extended Natural Gradient
    Xue, Yufeng
    Wang, Yujia
    Sun, Qiudong
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 3570 - +
  • [22] Motion Artifact Removal for PPG Signals based on Accurate Fundamental Frequency Estimation and Notch Filtering
    Zhang, Qirui
    Xie, Qingsong
    Wang, Min
    Wang, Guoxing
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 2965 - 2968
  • [23] An Accurate Non-accelerometer-based PPG Motion Artifact Removal Technique using CycleGAN
    Afandizadeh Zargari A.H.
    Aqajari S.A.H.
    Khodabandeh H.
    Rahmani A.
    Kurdahi F.
    ACM Transactions on Computing for Healthcare, 2023, 4 (01):
  • [24] PPG heart rate extraction algorithm based on the motion artifact intensity Classification and removal framework
    Hao, Zihao
    Wang, Jinnan
    Zhang, Ge
    Gao, Lizhen
    Zhang, Xiaoming
    Liu, Jun
    Zhang, Xiaoliang
    Yang, Xiaolei
    Lai, Zhengxi
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 94
  • [25] Novel Robust-to-Motion-Artifact Detection of Atrial Fibrillation Based on PPG Only
    Huang, Ching-Hui
    Duc Huy Nguyen
    Chao, Paul C. -P.
    2023 IEEE SENSORS, 2023,
  • [26] Anomaly Detection of Motion Artifact in Photoplethysmography (PPG) Sensors Using Unsupervised Learning
    Kwon, Taerim
    Yoon, Sang Won
    IEEE SENSORS JOURNAL, 2024, 24 (14) : 23163 - 23172
  • [27] A Novel Personalized Motion and Noise Artifact (MNA) Detection Method for Smartphone Photoplethysmography (PPG) Signals
    Tabei, Fatemehsadat
    Kumar, Rajnish
    Tra Nguyen Phan
    McManus, David D.
    Chong, Jo Woon
    IEEE ACCESS, 2018, 6 : 60498 - 60512
  • [28] NOISE REMOVAL IN MONITORING SENSORS OF CIVIL STRUCTURES USING BLIND SOURCE SEPARATION
    Santos, Daniel Moraes
    Paschoarelli Veiga, Antonio Claudio
    INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2016, 12 (06): : 1989 - 2009
  • [29] A Novel Evolutionary Approach for Blind Source Separation Based on Stone's Method
    Ahmed, Abdullah
    Zhu, Zhang Chao
    Yan, Cang
    PROCEEDINGS OF 2012 IEEE 11TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP) VOLS 1-3, 2012, : 324 - 328
  • [30] A Novel Underdetermined Blind Source Separation Method Based on OPTICS and Subspace Projection
    Wang, Qingyi
    Zhang, Yiqiong
    Yin, Shuai
    Wang, Yuduo
    Wu, Genping
    SYMMETRY-BASEL, 2021, 13 (09):