A NOVEL METHOD FOR MOTION ARTIFACT REMOVAL IN WEARABLE PPG SENSORS BASED ON BLIND SOURCE SEPARATION

被引:0
|
作者
Pflugradt, Maik [1 ]
Rose, Marcus [1 ]
Orglmeister, Reinhold [1 ]
机构
[1] TU Berlin, Elect & Med Signal Proc, Berlin, Germany
关键词
Blind Source Separation; Motion Artifacts; Body Sensor Network; ANC; ICA;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The recent development of healthcare systems has provided a significant contribution to ambulatory patient monitoring. In that context, signal quality and disturbances induced by noise or motion artifacts play an important role in the field of signal processing tasks. Especially the Photoplethysmogram (PPG) is very liable to movement artifacts which severely hamper the extraction of vital parameters like the heart rate or oxygen saturation. To record patient movements, an innovative sensor system is proposed, which acquires accelerometer data next to the PPG. As in Adaptive Noise Cancelers, we propose to use the acceleration as reference to recover corrupted PPGs by means of the Blind Source Separation. Sophisticated methods of ICA have been used, resulting in a novel approach for artifact suppression in the PPG that has been tested on laboratory datasets.
引用
收藏
页数:2
相关论文
共 50 条
  • [11] Noise cancellation model validation for reduced motion artifact wearable PPG sensors using MEMS accelerometers
    Wood, Levi B.
    Asada, H. Harry
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2628 - +
  • [12] Motion tolerance in wearable sensors - The challenge of motion artifact
    Such, Olaf
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1542 - 1545
  • [13] GUI Creation for Removal of Motion Artifact in PPG Signals
    Yadhuraj, S. R.
    Sudarshan, B. G.
    Kumar, Prasanna S. C.
    2016 3RD INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING AND COMMUNICATION SYSTEMS (ICACCS), 2016,
  • [14] Autoencoder-Based Motion Artifact Reduction in Photoplethysmography (PPG) Signals Acquired from Wearable Sensors during Construction Tasks
    Gautam, Yogesh
    Jebelli, Houtan
    CONSTRUCTION RESEARCH CONGRESS 2024: HEALTH AND SAFETY, WORKFORCE, AND EDUCATION, 2024, : 719 - 728
  • [15] Active motion artifact reduction for wearable sensors using Laguerre expansion and signal separation
    Wood, Levi B.
    Asada, H. Harry
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3571 - 3574
  • [16] A novel method of blind source separation
    Shen, YJ
    Yang, SP
    Xing, HJ
    ICEMI 2005: CONFERENCE PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL 7, 2005, : 522 - 525
  • [17] Quantitative Evaluation of Artifact Removal in Real Magnetoencephalogram Signals with Blind Source Separation
    Escudero, Javier
    Hornero, Roberto
    Abasolo, Daniel
    Fernandez, Alberto
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (08) : 2274 - 2286
  • [18] Quantitative Evaluation of Artifact Removal in Real Magnetoencephalogram Signals with Blind Source Separation
    Javier Escudero
    Roberto Hornero
    Daniel Abásolo
    Alberto Fernández
    Annals of Biomedical Engineering, 2011, 39 : 2274 - 2286
  • [19] A New Blind Source Separation Method to Remove Artifact in EEG Signals
    Zhang Chaozhu
    Lian Siyao
    Abdullah, Ahmed Kareem
    2013 THIRD INTERNATIONAL CONFERENCE ON INSTRUMENTATION & MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2013, : 1430 - 1433
  • [20] Motion artifact removal based on periodical property for ECG monitoring with wearable systems
    Zou, Chen
    Qin, Yajie
    Sun, Chenglu
    Li, Wei
    Chen, Wei
    PERVASIVE AND MOBILE COMPUTING, 2017, 40 : 267 - 278