Reversible Ratiometric Electrochemiluminescence Biosensor Based on DNAzyme Regulated Resonance Energy Transfer for Myocardial miRNA Detection

被引:38
作者
Sun, Yudie [1 ]
Fang, La [1 ]
Han, Yunxiang [1 ]
Feng, Aobo [1 ]
Liu, Shengjun [1 ]
Zhang, Kui [1 ]
Xu, Jing-Juan [2 ]
机构
[1] Anhui Univ Technol, Sch Chem & Chem Engn, Maanshan 243032, Anhui, Peoples R China
[2] Nanjing Univ, State Key Lab Analyt Chem Life Sci, Sch Chem & Chem Engn, Nanjing 210023, Peoples R China
基金
中国国家自然科学基金;
关键词
QUANTUM DOTS; AMPLIFICATION; FLUORESCENCE; COMBINATION; NANOPARTICLES; MICRORNAS; PROBE;
D O I
10.1021/acs.analchem.2c00195
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Myocardial miRNAs in peripheral blood are closely related to the pathogenic process of myocardial infarction. Rapid identification and accurate quantification of myocardial miRNAs are of great significance to clinical interventions for treating cardiovascular lesions. Therefore, a ratiometric electrochemiluminescence (ECL) biosensor integrating DNAzyme with a resonance energy transfer (RET) system was designed to detect myocardial miRNA. The dual-signal system was composed of rA marked substrate strand functionalized CdTe quantum dots (QDs) as reductive-oxidative (R-O) emitters and Cy5-labeled strand-functionalized Ru(bpy)(3)(2+)-filled silica nanoparticles (RuSi NPs) as oxidative-reductive (O-R) emitters. In the presence of target miRNA, DNAzyme was activated to cut substrate strands on the CdTe QDs and release triggers for opening hairpin probes. Then, the Cy5 molecule-labeled hairpin DNA on the RuSi NPs was opened to introduce Cy5 molecules and RuSi NPs into the system. The R-O ECL was quenched by ECL-RET between CdTe QDs and Cy5 molecules and the O-R ECL was introduced by the RuSi NPs. In this way, based on the simultaneous changing of the ECL signal, the dual-potential dynamic signal ratiometric ECL sensing platform was developed. By measuring the ratio of O-R ECL signal to R-O ECL signal, the concentration of miRNA-499 was accurately quantified in the range of 10 fM to 10 nM, and the detection limit was as low as 2.44 NI (S/N = 3). This DNAzyme guided dual-potential ratiometric ECL method provides a sensitive and reliable method for myocardial miRNA detection, and it has great potential in clinical diagnosis and treatment.
引用
收藏
页码:7035 / 7040
页数:6
相关论文
共 50 条
[31]   A ratiometric lysosomal pH chemosensor based on fluorescence resonance energy transfer [J].
Fan, Jiangli ;
Lin, Chunying ;
Li, Honglin ;
Zhan, Peng ;
Wang, Jingyun ;
Cui, Shuang ;
Hu, Mingming ;
Cheng, Guanghui ;
Peng, Xiaojun .
DYES AND PIGMENTS, 2013, 99 (03) :620-626
[32]   Detection of tumor marker miRNA21 based on phosphorescent resonance energy transfer of Mn-ZnS QDs [J].
Lv, Jinzhi ;
Miao, Yanming ;
Yan, Guiqin .
RSC ADVANCES, 2017, 7 (65) :41063-41069
[33]   Electrochemiluminescence Biosensor Based on Entropy-Driven Amplification and a Tetrahedral DNA Nanostructure for miRNA-133a Detection [J].
Yu, Linying ;
Zhu, Liping ;
Yan, Mengxia ;
Feng, Sinuo ;
Huang, Jianshe ;
Yang, Xiurong .
ANALYTICAL CHEMISTRY, 2021, 93 (34) :11809-11815
[34]   An electrochemiluminescence resonance energy transfer biosensor based on CDs/PAMAM/rGO nanocomposites and Au@Ag2S nanoparticles for PML/RARa fusion gene detection [J].
Zhang, Zi-Yang ;
Lin, Mu-Tu ;
Zhang, Yu ;
Cheng, Zhang-Jian ;
Han, Shu-Hua ;
Liu, Ai-Lin ;
Lei, Yun .
MICROCHIMICA ACTA, 2023, 190 (10)
[35]   Ratiometric electrochemiluminescence biosensor based on Ru(dcbpy)32+and TiO2 quantum dots for the detection of Urokinase [J].
Wang, Mingxia ;
Wei, Minggang ;
Liu, Sirui ;
Yue, Xidian ;
Wang, Li ;
Luan, Feng ;
Zhuang, Xuming ;
Tian, Chunyuan .
TALANTA, 2026, 296
[36]   An electrochemiluminescence sensor for 17β-estradiol detection based on resonance energy transfer in α-FeOOH@CdS/Ag NCs [J].
Liu, Yixin ;
Li, Binxiao ;
Yao, Yuanyuan ;
Yang, Beibei ;
Tian, Tongtong ;
Miao, Yan ;
Liu, Baohong .
TALANTA, 2021, 221
[37]   Electrochemiluminescence Resonance Energy Transfer Biosensor for the Human-Associated Clade of Streptococcus suis Based on Prereduction-Enhanced Yttrium MOFs [J].
Hu, Can ;
Xiang, Hongzhang ;
Yin, Yashi ;
Li, Jiawen ;
Zhang, Yutian ;
Huang, Xingao ;
Guo, Yating ;
He, Yingsi ;
Gao, Yanru ;
Ren, Kejing ;
Han, Heyou ;
Wang, Wenjing ;
Li, Jinquan .
ANALYTICAL CHEMISTRY, 2025, 97 (05) :3153-3160
[38]   Design and Biosensing of a Ratiometric Electrochemiluminescence Resonance Energy Transfer Aptasensor between a g-C3N4 Nanosheet and Ru@MOF for Amyloid-β Protein [J].
Wang, Yinfang ;
Zhang, Yao ;
Sha, Haifeng ;
Xiong, Xin ;
Jia, Nengqin .
ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (40) :36299-36306
[39]   A near infrared fluorescence resonance energy transfer based aptamer biosensor for insulin detection in human plasma [J].
Wang, Yuhui ;
Gao, Duyang ;
Zhang, Pengfei ;
Gong, Ping ;
Chen, Chi ;
Gao, Guanhui ;
Cai, Lintao .
CHEMICAL COMMUNICATIONS, 2014, 50 (07) :811-813
[40]   A portable fluorescence resonance energy transfer biosensor for rapid detection of silver ions [J].
Chen, Yi-Ju ;
Liu, Cheng-You ;
Tsai, Dong-Yu ;
Yeh, Yi-Chun .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 259 :784-788