Reversible Ratiometric Electrochemiluminescence Biosensor Based on DNAzyme Regulated Resonance Energy Transfer for Myocardial miRNA Detection

被引:35
作者
Sun, Yudie [1 ]
Fang, La [1 ]
Han, Yunxiang [1 ]
Feng, Aobo [1 ]
Liu, Shengjun [1 ]
Zhang, Kui [1 ]
Xu, Jing-Juan [2 ]
机构
[1] Anhui Univ Technol, Sch Chem & Chem Engn, Maanshan 243032, Anhui, Peoples R China
[2] Nanjing Univ, State Key Lab Analyt Chem Life Sci, Sch Chem & Chem Engn, Nanjing 210023, Peoples R China
基金
中国国家自然科学基金;
关键词
QUANTUM DOTS; AMPLIFICATION; FLUORESCENCE; COMBINATION; NANOPARTICLES; MICRORNAS; PROBE;
D O I
10.1021/acs.analchem.2c00195
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Myocardial miRNAs in peripheral blood are closely related to the pathogenic process of myocardial infarction. Rapid identification and accurate quantification of myocardial miRNAs are of great significance to clinical interventions for treating cardiovascular lesions. Therefore, a ratiometric electrochemiluminescence (ECL) biosensor integrating DNAzyme with a resonance energy transfer (RET) system was designed to detect myocardial miRNA. The dual-signal system was composed of rA marked substrate strand functionalized CdTe quantum dots (QDs) as reductive-oxidative (R-O) emitters and Cy5-labeled strand-functionalized Ru(bpy)(3)(2+)-filled silica nanoparticles (RuSi NPs) as oxidative-reductive (O-R) emitters. In the presence of target miRNA, DNAzyme was activated to cut substrate strands on the CdTe QDs and release triggers for opening hairpin probes. Then, the Cy5 molecule-labeled hairpin DNA on the RuSi NPs was opened to introduce Cy5 molecules and RuSi NPs into the system. The R-O ECL was quenched by ECL-RET between CdTe QDs and Cy5 molecules and the O-R ECL was introduced by the RuSi NPs. In this way, based on the simultaneous changing of the ECL signal, the dual-potential dynamic signal ratiometric ECL sensing platform was developed. By measuring the ratio of O-R ECL signal to R-O ECL signal, the concentration of miRNA-499 was accurately quantified in the range of 10 fM to 10 nM, and the detection limit was as low as 2.44 NI (S/N = 3). This DNAzyme guided dual-potential ratiometric ECL method provides a sensitive and reliable method for myocardial miRNA detection, and it has great potential in clinical diagnosis and treatment.
引用
收藏
页码:7035 / 7040
页数:6
相关论文
共 50 条
  • [21] An "on-off" signal-switchable electrochemiluminescence biosensor for ultrasensitive detection of dual microRNAs based on DNAzyme-powered DNA walker
    Wang, Li
    Zhao, Kai-Ren
    Liu, Zhi-Jun
    Zhang, Yi-Bang
    Liu, Peng-Fei
    Ye, Shu-Ying
    Zhang, Ye-Wang
    Liang, Guo-Xi
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2021, 348
  • [22] A new strategy for the detection of adenosine triphosphate by aptamer/quantum dot biosensor based on chemiluminescence resonance energy transfer
    Zhou, Zi-Ming
    Yu, Yong
    Zhao, Yuan-Di
    [J]. ANALYST, 2012, 137 (18) : 4262 - 4266
  • [23] Aggregation-disaggregation regulated fluorescence resonance energy transfer of perovskite nanocrystals for the detection of ascorbic acid
    Yin, Qian-Wei
    Wang, Ji
    Liu, Jin-Zhou
    Huang, Jing-Tao
    Yang, Cheng-Kang
    Li, Rong-Sheng
    Ling, Jian
    Cao, Qiue
    [J]. MICROCHEMICAL JOURNAL, 2024, 207
  • [24] Micellular fluorescence resonance energy transfer based fluorescent ratiometric response to hydrocarbon analytes
    Gordon, Calum K.
    Nass, Liselotte
    Chan, Sanutep
    Davis, Nathaniel J. L. K.
    [J]. LUMINESCENCE, 2024, 39 (02)
  • [25] Electrochemiluminescence Resonance Energy Transfer System Based on Silver Metal-Organic Frameworks as a Double-Amplified Emitter for Sensitive Detection of miRNA-107
    Xiao, Siyu
    Wang, Xiaoyan
    Yang, Changping
    Jiang, Yongjian
    Zhen, Shujun
    Huang, Chengzhi
    Li, Yuanfang
    [J]. ANALYTICAL CHEMISTRY, 2022, 94 (02) : 1178 - 1186
  • [26] Ratiometric fluorescence immunoassay based on MnO2-o-phenylenediamine-fluorescent carbon nanodots for the detection of α-fetoprotein via fluorescence resonance energy transfer
    Liu, Wenwen
    Kang, Qing
    Wang, Pengcheng
    Zhou, Feimeng
    [J]. NEW JOURNAL OF CHEMISTRY, 2022, 46 (03) : 1120 - 1126
  • [27] A Biosensor Based on Catalytic Hairpin Assembly and Fluorescence Resonance Energy Transfer for Detection of Enterovirus 71
    Tian, Zi-Yi
    Xu, Mu-Cen
    Hu, Shun-Ming
    Zhang, Chu-Yan
    Chen, Chen
    Li, Yong-Xin
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 51 (01) : 93 - 101
  • [28] Detection of Citrus tristeza virus by using fluorescence resonance energy transfer-based biosensor
    Shojaei, Taha Roodbar
    Salleh, Mohamad Amran Mohd
    Sijam, Kamaruzaman
    Rahim, Raha Abdul
    Mohsenifar, Afshin
    Safarnejad, Reza
    Tabatabaei, Meisam
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 169 : 216 - 222
  • [29] Glycopolymer Decorated pH-Dependent Ratiometric Fluorescent Probe Based on Forster Resonance Energy Transfer for the Detection of Cancer Cells
    Bhattacharya, Koushik
    Kundu, Moumita
    Das, Subhayan
    Samanta, Sarthik
    Roy, Sib Sankar
    Mandal, Mahitosh
    Singha, Nikhil K.
    [J]. MACROMOLECULAR RAPID COMMUNICATIONS, 2023, 44 (02)
  • [30] A ratiometric lysosomal pH chemosensor based on fluorescence resonance energy transfer
    Fan, Jiangli
    Lin, Chunying
    Li, Honglin
    Zhan, Peng
    Wang, Jingyun
    Cui, Shuang
    Hu, Mingming
    Cheng, Guanghui
    Peng, Xiaojun
    [J]. DYES AND PIGMENTS, 2013, 99 (03) : 620 - 626