Reversible Ratiometric Electrochemiluminescence Biosensor Based on DNAzyme Regulated Resonance Energy Transfer for Myocardial miRNA Detection

被引:35
|
作者
Sun, Yudie [1 ]
Fang, La [1 ]
Han, Yunxiang [1 ]
Feng, Aobo [1 ]
Liu, Shengjun [1 ]
Zhang, Kui [1 ]
Xu, Jing-Juan [2 ]
机构
[1] Anhui Univ Technol, Sch Chem & Chem Engn, Maanshan 243032, Anhui, Peoples R China
[2] Nanjing Univ, State Key Lab Analyt Chem Life Sci, Sch Chem & Chem Engn, Nanjing 210023, Peoples R China
基金
中国国家自然科学基金;
关键词
QUANTUM DOTS; AMPLIFICATION; FLUORESCENCE; COMBINATION; NANOPARTICLES; MICRORNAS; PROBE;
D O I
10.1021/acs.analchem.2c00195
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Myocardial miRNAs in peripheral blood are closely related to the pathogenic process of myocardial infarction. Rapid identification and accurate quantification of myocardial miRNAs are of great significance to clinical interventions for treating cardiovascular lesions. Therefore, a ratiometric electrochemiluminescence (ECL) biosensor integrating DNAzyme with a resonance energy transfer (RET) system was designed to detect myocardial miRNA. The dual-signal system was composed of rA marked substrate strand functionalized CdTe quantum dots (QDs) as reductive-oxidative (R-O) emitters and Cy5-labeled strand-functionalized Ru(bpy)(3)(2+)-filled silica nanoparticles (RuSi NPs) as oxidative-reductive (O-R) emitters. In the presence of target miRNA, DNAzyme was activated to cut substrate strands on the CdTe QDs and release triggers for opening hairpin probes. Then, the Cy5 molecule-labeled hairpin DNA on the RuSi NPs was opened to introduce Cy5 molecules and RuSi NPs into the system. The R-O ECL was quenched by ECL-RET between CdTe QDs and Cy5 molecules and the O-R ECL was introduced by the RuSi NPs. In this way, based on the simultaneous changing of the ECL signal, the dual-potential dynamic signal ratiometric ECL sensing platform was developed. By measuring the ratio of O-R ECL signal to R-O ECL signal, the concentration of miRNA-499 was accurately quantified in the range of 10 fM to 10 nM, and the detection limit was as low as 2.44 NI (S/N = 3). This DNAzyme guided dual-potential ratiometric ECL method provides a sensitive and reliable method for myocardial miRNA detection, and it has great potential in clinical diagnosis and treatment.
引用
收藏
页码:7035 / 7040
页数:6
相关论文
共 50 条
  • [11] A DNAzyme-Based Dual-Stimuli Responsive Electrochemiluminescence Resonance Energy Transfer Platform for Ultrasensitive Anatoxin-a Detection
    Xia, Mengmeng
    Zhou, Fu
    Feng, Xiuyun
    Sun, Jiahui
    Wang, Li
    Li, Na
    Wang, Xiayan
    Wang, Guangfeng
    ANALYTICAL CHEMISTRY, 2021, 93 (32) : 11284 - 11290
  • [12] An electrochemiluminescence resonance energy transfer biosensor for the detection of circulating tumor DNA from blood plasma
    Yang, Xidong
    Liao, Meiyan
    Zhang, Hanfei
    Gong, JinBo
    Yang, Fan
    Xu, Mengying
    Tremblay, Pier-Luc
    Zhang, Tian
    ISCIENCE, 2021, 24 (09)
  • [13] A wavelength-resolved electrochemiluminescence resonance energy transfer ratiometric immunosensor for detection of cardiac troponin I
    Zhu, Liping
    Ye, Jing
    Yan, Mengxia
    Zhu, Qiuju
    Yang, Xiurong
    ANALYST, 2019, 144 (22) : 6554 - 6560
  • [14] Resonance energy transfer-based electrochemiluminescence aptasensor for serotonin detection
    Guo, Yuehua
    Xu, Yinjin
    Wu, Meisheng
    Feng, Qiumei
    TALANTA, 2025, 281
  • [15] An ultrasensitive electrochemiluminescence resonance energy transfer biosensor for divalent mercury monitoring
    Cao, Shu-Ping
    Hu, Hui-Min
    Liang, Ru-Ping
    Qiu, Jian-Ding
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 856
  • [16] An electrochemiluminescence resonance energy transfer biosensor based on Luminol-LDH and CuS@Pt for detection of alpha-fetoprotein
    Liang, Wenjin
    Cong, Bing
    Lai, Wenjing
    Jiang, Mingzhe
    Ma, Chaoyun
    Zhao, Chulei
    Jiang, Wenwen
    Zhang, Shaopeng
    Qi, Yu
    Hong, Chenglin
    TALANTA, 2023, 261
  • [17] Ratiometric biosensor array for multiplexed detection of microRNAs based on electrochemiluminescence coupled with cyclic voltammetry
    Feng, Xiaobin
    Gan, Ning
    Zhang, Huairong
    Li, Tianhua
    Cao, Yuting
    Hu, Futao
    Jiang, Qianli
    BIOSENSORS & BIOELECTRONICS, 2016, 75 : 308 - 314
  • [18] Ratiometric electrochemiluminescence sensing and intracellular imaging of ClO- via resonance energy transfer
    Ma, Cheng
    Zhu, Yujing
    Zhang, Zhichen
    Chen, Xuan
    Ji, Zhengping
    Zhang, Lu-Nan
    Xu, Qin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (21) : 4691 - 4703
  • [19] Electrochemiluminescence Resonance Energy Transfer System: Mechanism and Application in Ratiometric Aptasensor for Lead Ion
    Lei, Yan-Mei
    Huang, Wei-Xing
    Zhao, Min
    Chai, Ya-Qin
    Yuan, Ruo
    Zhuo', Ying
    ANALYTICAL CHEMISTRY, 2015, 87 (15) : 7787 - 7794
  • [20] Dual "on-off" signal conversion strategy based on surface plasmon coupling and resonance energy transfer for visual electrochemiluminescence ratiometric analysis of MiRNA-141
    Wang, Yin-Zhu
    Wang, Ling-Ling
    Liu, Yan
    Zhang, Yu-Qi
    Li, Meng-Li
    Chen, Chuan-Xiang
    Zhu, Jia-Wan
    Yang, Fu
    Hu, Yong-Hong
    BIOSENSORS & BIOELECTRONICS, 2024, 253