Reconstruction of Large Acetabular Defects Using Trabecular Metal Augments

被引:0
|
作者
Hasart, Olaf [1 ]
Perka, Carsten [1 ]
Lehnigk, Rex [1 ]
Tohtz, Stephan [1 ]
机构
[1] Charite, Ctr Musculoskeletale Chirurg, Klin Orthopadie, D-10117 Berlin, Germany
来源
OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE | 2010年 / 22卷 / 03期
关键词
Revision surgery; Modular implant; Metal augment; Trabecular metal; Acetabular defects; FEMORAL-HEAD ALLOGRAFTS; TOTAL HIP-ARTHROPLASTY; COMPONENTS; FIXATION; CUP; POSTMORTEM; STABILITY; IMPLANTS; FAILURE; BONE;
D O I
10.1007/s00064-010-8026-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Revision of cup and reconstruction of original center of rotation. High primary and secondary stability. Prevention of additional bone loss. Indications Osseous defects at the anterior-cranial, cranial and posterior-cranial rim of acetabulum. Larger cavitary, medial or oval defects (Paprosky IIb-IIIb). Segmental defects (anterior column up to half of host bone, posterior column up to one third of host bone). Contraindications Infection of total hip arthroplasty. Pelvic discontinuity (Paprosky IV). Surgical Technique Exposure of acetabulum and detection of defects. Complete removal of soft tissue from acetabulum, reaming of sclerotic bone, if necessary. Adaptation of trial augments to close an oval defect to a round defect and to reach an uncontained defect, respectively. Adaptation of trial cup. In case of sufficient stability, fixation of final augment with two or three screws in cranial bone stock. The screws should be directed to iliosacral joint. Augmentation with allogenic bone chips is possible in the region of wedge and acetabulum as well. Sealing of rough augment surface with bone cement. Implantation of cup, fixation with screws. Application of insert. Postoperative Management Depending on bone defects, full weight bearing is possible. In cases of severe bone defects, reduction of weight bearing to 20 kg for 6 weeks is recommended. Postoperative physiotherapy is possible in most cases. Results Between 2005 and 2007,38 patients with acetabular defects type IIIa und IIIb according to Paprosky underwent reconstruction using the TMT system (Trabecular Metal Technology). After 25 months, a significant functional improvement was seen in all patients. The Merle d'Aubigne Score increased from 6 points preoperatively to 13 points postoperatively, the Harris Hip Score from 29 to 78 points. Two revisions were necessary because of loosening or migration of the cup.
引用
收藏
页码:268 / 277
页数:10
相关论文
共 50 条
  • [1] Rekonstruktion größerer Pfannendefekte mit metallischen Augmentaten – Trabecular Metal TechnologyReconstruction of Large Acetabular Defects Using Trabecular Metal Augments
    Olaf Hasart
    Carsten Perka
    Rex Lehnigk
    Stephan Tohtz
    Operative Orthopädie und Traumatologie, 2010, 22 (3) : 268 - 277
  • [2] Acetabular Revisions Using Trabecular Metal Cups and Augments
    Van Kleunen, Jonathan P.
    Lee, Gwo-Chin
    Lementowski, Peter W.
    Nelson, Charles L.
    Garino, Jonathan P.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (06) : 64 - 68
  • [3] Acetabular Revision Using Trabecular Metal Augments for Paprosky Type 3 Defects
    O'Neill, Cathleen J.
    Creedon, Stephen B.
    Brennan, Stephen A.
    O'Mahony, Fiona J.
    Lynham, Rosanne S.
    Guerin, Shane
    Gul, Rehan
    Harty, James A.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (03) : 823 - 828
  • [4] Letter to the Editor on "Acetabular Revision Using Trabecular Metal Augments for Paprosky Type 3 Defects"
    Luo, Ze-Yu
    Wang, Duan
    Zhou, Zong-Ke
    JOURNAL OF ARTHROPLASTY, 2018, 33 (06) : 1982 - 1983
  • [5] Results using Trabecular Metal™ augments in combination with acetabular impaction bone grafting in deficient acetabula
    Gill, Kathryn
    Wilson, Matthew J.
    Whitehouse, Sarah L.
    Timperley, A. John
    HIP INTERNATIONAL, 2013, 23 (06) : 522 - 528
  • [6] Treatment of Severe Acetabular Defects With an Antiprotrusio Cage and Trabecular Metal Augments - Clinical and Radiographic Results After a Mean Follow-Up of 6.6 Years
    Bellova, Petri
    Reich, Marie-Christin
    Grothe, Tim
    Guenther, Klaus-Peter
    Stiehler, Maik
    Goronzy, Jens
    JOURNAL OF ARTHROPLASTY, 2023, 38 (11) : 2415 - 2422
  • [7] Trabecular Metal Augments for Severe Acetabular Defects in Revision Hip Arthroplasty: A Long-Term Follow-Up
    Russell, Shane P.
    O'Neill, Cathleen J.
    Fahey, Eoin J.
    Guerin, Shane
    Gul, Rehan
    Harty, James A.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (05) : 1740 - 1745
  • [8] Results of trabecular metal augments in Paprosky IIIA and IIIB defects A MULTICENTRE STUDY
    Eachempati, K. K.
    Malhotra, R.
    Pichai, S.
    Reddy, A. V. G.
    Subramani, A. K. Podhili
    Gautam, D.
    Bollavaram, V. R.
    Sheth, N. P.
    BONE & JOINT JOURNAL, 2018, 100B (07) : 903 - 908
  • [9] Trabecular metal augments in severe malignancy-associated acetabular bone loss
    Melnic, Christopher M.
    Salimy, Mehdi S.
    Hosseinzadeh, Shayan
    Moverman, Michael A.
    Bedair, Hany S.
    Lozano-Calderon, Santiago A.
    Raskin, Kevin A.
    HIP INTERNATIONAL, 2023, 33 (04) : 678 - 684
  • [10] Reconstruction of Paprosky IIIB acetabular defects with porous tantalum shells and augments using the footing technique
    Wassilew, G. I.
    Zimmerer, A.
    Fischer, M.
    Nonnenmacher, L.
    O'Hara, L.
    Hube, R.
    BONE & JOINT JOURNAL, 2024, 106B (05) : 54 - 58