Effect of bite distance of an epitendinous suture from the repair site on the tensile strength of canine tendon constructs

被引:12
作者
Duffy, Daniel J. [1 ]
Cocca, Christina J. [2 ]
Kersh, Mariana E. [3 ]
Kim, Woojae [3 ]
Moore, George E. [4 ]
机构
[1] North Carolina State Univ, Dept Clin Sci, Coll Vet Med, Raleigh, NC 27607 USA
[2] Univ Illinois, Coll Vet Med, Dept Vet Clin Sci, Urbana, IL 61802 USA
[3] Univ Illinois, Dept Mech Sci & Engn, Coll Engn, Urbana, IL 61801 USA
[4] Purdue Univ, Coll Vet Med, Vet Adm, W Lafayette, IN 47906 USA
关键词
INTRASYNOVIAL FLEXOR TENDONS; 3-LOOP PULLEY SUTURE; GAP FORMATION; ZONE-II; LOCKING; CORE;
D O I
10.2460/ajvr.80.11.1034
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
OBJECTIVE To evaluate effects of bite distance of an interlocking horizontal mattress epitendinous suture (IHMES) from the repair site on tensile strength of canine tendon repairs. SAMPLE 72 canine cadaveric superficial digital flexor tendons (SDFTs). PROCEDURES Transverse tenotomy was performed, and SDFTs were repaired with a locking-loop construct (LL construct) or 3 LL constructs with IHMES suture bites placed 5 (LL + 5ES construct), 10 (LL + 10ES construct), or 15 (LL + 15ES construct) mm from the transection site (18 SDFTs/group). Constructs were loaded to failure. Load at 1- and 3-mm gapping, yield force, failure load, and failure mode were evaluated. RESULTS Mean +/- SD yield force and failure load for LL constructs were significantly lower than for IHMES constructs. Load at 1- and 3-mm gapping was significantly higher for IHMES constructs. Increasing the bite distance significantly increased construct strength (134.4 +/- 26.1 N, 151.0 +/- 16.8 N, and 182.1 +/- 23.6 N for LL + 5ES, LL + 10ES, and LL + 15ES constructs, respectively), compared with strength for the LL construct. Failure mode differed significantly among constructs when an IHMES was used. CONCLUSIONS AND CLINICAL RELEVANCE Addition of an IHMES to an LL construct led to increased ultimate tensile strength by 2.5 times and significantly reduced gap formation. Increasing the IHMES bite distance increased yield force by 2.1, 2.3, and 2.7 times for bites placed 5, 10, and 15 mm from the tenotomy, respectively. Positioning an IHMES at a greater distance from the repair site provided superior biomechanical strength for tendon repairs in dogs.
引用
收藏
页码:1034 / 1042
页数:9
相关论文
共 29 条
  • [21] The effect of increased peripheral suture purchase on the strength of flexor tendon repairs
    Merrell, GA
    Wolfe, SW
    Kacena, WJ
    Gao, YT
    Cholewicki, J
    Kacena, MA
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (03): : 464 - 468
  • [22] Moores AP, 2004, VET SURG, V33, P131, DOI [10.1111/j.1532-950x.2004.04020.x, 10.1111/j.1532-950X.2004.04020.x]
  • [23] CYCLIC STRESS-ANALYSIS OF FLEXOR TENDON REPAIR
    PRUITT, DL
    MANSKE, PR
    FINK, B
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (04): : 701 - 707
  • [24] GAP FORMATION AFTER FLEXOR TENDON REPAIR IN ZONE-II - RESULTS WITH A NEW CONTROLLED MOTION PROGRAM
    SILFVERSKIOLD, KL
    MAY, EJ
    [J]. SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1993, 27 (04): : 263 - 268
  • [25] FLEXOR TENDON REPAIR IN ZONE-II WITH A NEW SUTURE TECHNIQUE AND AN EARLY MOBILIZATION PROGRAM COMBINING PASSIVE AND ACTIVE FLEXION
    SILFVERSKIOLD, KL
    MAY, EJ
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (01): : 53 - 60
  • [26] 2 NEW METHODS OF TENDON REPAIR - AN INVITRO EVALUATION OF TENSILE-STRENGTH AND GAP FORMATION
    SILFVERSKIOLD, KL
    ANDERSSON, CH
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (01): : 58 - 65
  • [27] Strickland JW, 2000, J HAND SURG-AM, V25A, P214
  • [28] PRIMARY FLEXOR TENDON REPAIR - THE MECHANICAL LIMITATIONS OF THE MODIFIED KESSLER TECHNIQUE
    WADE, PJF
    MUIR, IFK
    HUTCHEON, LL
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1986, 11B (01) : 71 - 76
  • [29] The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair
    Wieskoetter, B.
    Herbort, M.
    Langer, M.
    Raschke, M. J.
    Waehnert, D.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (01) : 139 - 145