Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

被引:7
作者
Kim, Ho Chul [1 ]
Kim, Hee-Joung [2 ]
Kim, Kyuseok [2 ]
Lee, Min-Hee [3 ]
Lee, Youngjin [1 ]
机构
[1] Eulji Univ, Dept Radiol Sci, 553 Sanseong Daero, Seongnam Si 13135, Gyeonggi Do, South Korea
[2] Yonsei Univ, Dept Radiol Sci, 1 Yonseidae Gil, Wonju 26493, South Korea
[3] Yonsei Univ, Dept Biomed Engn, 1 Yonseidae Gil, Wonju 26493, South Korea
关键词
Medical Application; Monte Carlo Simulation; Nuclear Medicine; Photon Counting Detector; Scintillation Detector; Single-Photon Emission Computed Tomography System; PARALLEL-HOLE COLLIMATOR; GAMMA-CAMERA; PERFORMANCE EVALUATION; SPECT; RESOLUTION; DETECTORS; CDTE;
D O I
10.1016/j.net.2016.12.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a Tc-99m gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector. (C) 2017 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:776 / 780
页数:5
相关论文
共 19 条
  • [1] Abdelhalim Mohamed Anwar K., 2009, Journal of King Saud University Science, V21, P145, DOI 10.1016/j.jksus.2009.06.001
  • [2] Performance evaluation of a hand-held, semiconductor (CdZnTe)-based gamma camera
    Abe, A
    Takahashi, N
    Lee, J
    Oka, T
    Shizukuishi, K
    Kikuchi, T
    Inoue, T
    Jimbo, M
    Ryuo, H
    Bickel, C
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (06) : 805 - 811
  • [3] Evaluation of a technique for simulation of gamma camera images
    Fleming, JS
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (09) : 1855 - 1861
  • [4] GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy
    Jan, S.
    Benoit, D.
    Becheva, E.
    Carlier, T.
    Cassol, F.
    Descourt, P.
    Frisson, T.
    Grevillot, L.
    Guigues, L.
    Maigne, L.
    Morel, C.
    Perrot, Y.
    Rehfeld, N.
    Sarrut, D.
    Schaart, D. R.
    Stute, S.
    Pietrzyk, U.
    Visvikis, D.
    Zahra, N.
    Buvat, I.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04) : 881 - 901
  • [5] SPECT - SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    JASZCZAK, RJ
    COLEMAN, RE
    LIM, CB
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (03) : 1137 - 1153
  • [6] Dose reduction and image quality optimizations in CT of pediatric and adult patients: phantom studies
    Jeon, P-H.
    Lee, C-L.
    Kim, D-H.
    Lee, Y-J.
    Jeon, S-S.
    Kim, H-J.
    [J]. JOURNAL OF INSTRUMENTATION, 2014, 9
  • [7] Development of a miniature scintillation camera using an NaI(Tl) scintillator and PSPMT for scintimammography
    Kim, JH
    Choi, Y
    Joo, KS
    Sihn, BS
    Chong, JW
    Kim, SE
    Lee, KH
    Choe, YS
    Kim, BT
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) : 3481 - 3488
  • [8] GATE Simulations of Small Animal SPECT for Determination of Scatter Fraction as a Function of Object Size
    Koenik, Arda
    Madsen, Mark T.
    Sunderland, John J.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1887 - 1891
  • [9] Optimization of the SPECT systems based on a CdTe pixelated semiconductor detector using novel parallel-hole collimators
    Lee, Y. -J.
    Park, S. -J.
    Kim, D. -H.
    Kim, H. -J.
    [J]. JOURNAL OF INSTRUMENTATION, 2014, 9
  • [10] Comparison of ultra-high-resolution parallel-hole collimator materials based on the CdTe pixelated semiconductor SPECT system
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Lee, Seung-Wan
    Park, Su-Jin
    Kim, Hee-Joung
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 713 : 33 - 39