Effect of stimulus level on the temporal response properties of the auditory nerve in cochlear implants

被引:10
|
作者
Hughes, Michelle L. [1 ]
Laurello, Sarah A. [2 ,3 ]
机构
[1] Boys Town Natl Res Hosp, 555 North 30th St, Omaha, NE 68131 USA
[2] Univ Northern Colorado, Greeley, CO USA
[3] Massachusetts Eye & Ear, 243 Charles St, Boston, MA USA
基金
美国国家卫生研究院;
关键词
Cochlear implant; Electrically evoked compound action potential; Temporal responses; Adaptation; Refractory recovery; ELECTRICAL-STIMULATION; RECOVERY FUNCTION; ACTION-POTENTIALS; FIBER RESPONSES; SPATIAL SPREAD; DURATION; AMPLITUDE; INTEGRATION; EXCITATION; TIME;
D O I
10.1016/j.heares.2017.06.004
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Electrically evoked compound action potentials (ECAPs) have been used to examine temporal response patterns of the auditory nerve in cochlear implant (CI) recipients. ECAP responses to individual pulses in a pulse train vary across stimulation rates for individual CI users. For very slow rates, auditory neurons have ample time to discharge, recover, and respond to each pulse in the train. As the pulse rate increases, an alternating ECAP-amplitude pattern occurs. As the stimulation rate increases further, the alternating pattern eventually ceases and the overall ECAP amplitudes are diminished, yielding a relatively stochastic state that presumably reflects a combination of adaptation, desynchronization, and facilitation across fibers. Because CIs operate over a range of current levels in everyday use, it is important to understand auditory-nerve responses to pulse trains over a range of levels. The effect of stimulus level on ECAP temporal response patterns in human CI users has not been well studied. The first goal of this study was to examine the effect of stimulus level on various aspects of ECAP temporal responses to pulse-train stimuli. Because higher stimulus levels yield more synchronous responses and faster recovery, it was hypothesized that: (1) the maximum alternation would occur at slower rates for lower levels and faster rates at higher levels, (2) the alternation depth at its maximum would be smaller for lower levels, (3) the rate that produces a stochastic state ('stochastic rate') would decrease with level, (4) adaptation would be greater for lower levels as a result of slower recovery, and (5) refractory-recovery time constants would be longer (slower) for lower levels, consistent with earlier studies. The second goal of this study was to examine how refractory-recovery time constants relate specifically to maximum alternation and stochastic rate. Data were collected for 12 ears in 10 CI recipients. ECAPs were recorded in response to each of 13 pulses in an equal-amplitude pulse train ranging in rate from 900-3500 pps for three levels (low, medium, high). The results generally supported hypotheses 1-4; there were no significant effects of level on the refractory-recovery time constants (hypothesis 5). When data were pooled across level, there was a significant negative correlation between alternation depth and refractory recovery time. Understanding the effects of stimulus level on auditory-nerve responses may provide further insight into improving the use of objective measures for potentially optimizing speech-processing strategies. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:116 / 129
页数:14
相关论文
共 50 条
  • [31] Response properties of the refractory auditory nerve fiber
    Miller, CA
    Abbas, PJ
    Robinson, BK
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2001, 2 (03): : 216 - 232
  • [32] An evoked potential study of the developmental time course of the auditory nerve and brainstem in children using cochlear implants
    Gordon, KA
    Papsin, BC
    Harrison, RV
    AUDIOLOGY AND NEURO-OTOLOGY, 2006, 11 (01) : 7 - 23
  • [33] Is There Any Correlation between Spread of Excitation Width and the Refractory Properties of the Auditory Nerve in Cochlear Implant Users?
    Coutinho da Silva, Juliana
    Schmidt Goffi-Gomez, Maria Valeria
    Tsuji, Robinson Koji
    Bento, Ricardo
    Brito Neto, Rubens
    AUDIOLOGY AND NEURO-OTOLOGY, 2021, 26 (02) : 85 - 94
  • [34] The effect of early auditory experience on the spatial listening skills of children with bilateral cochlear implants
    Kilian, Catherine F.
    Royle, Nicola
    Totten, Catherine L.
    Raine, Christopher H.
    Lovett, Rosemary E. S.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2015, 79 (12) : 2159 - 2165
  • [35] Electrically evoked compound action potential (ECAP) in cochlear implant children: Changes in auditory nerve response in first year of cochlear implant use
    Telmesani, Laila M.
    Said, Nithreen M.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2016, 82 (03) : 28 - 33
  • [36] Effect of Level and Frequency of Forward Masker on Auditory Brainstem Response
    Kumar, Durga S.
    Konadath, Sreeraj
    AMERICAN JOURNAL OF AUDIOLOGY, 2024, 33 (04) : 1237 - 1245
  • [37] Variation in the Phase of Response to Low-Frequency Pure Tones in the Guinea Pig Auditory Nerve as Functions of Stimulus Level and Frequency
    Palmer, Alan R.
    Shackleton, Trevor M.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2009, 10 (02): : 233 - 250
  • [38] Basic response properties of auditory nerve fibers: a review
    Heil, Peter
    Peterson, Adam J.
    CELL AND TISSUE RESEARCH, 2015, 361 (01) : 129 - 158
  • [39] Basic response properties of auditory nerve fibers: a review
    Peter Heil
    Adam J. Peterson
    Cell and Tissue Research, 2015, 361 : 129 - 158
  • [40] Plasticity after pediatric cochlear implantation: Implication from changes in peripheral plasma level of BDNF and auditory nerve responses
    Alemi, Razieh
    Zarandy, Masoud Motassadi
    Joghataei, Mohammad Taghi
    Eftekharian, Ali
    Zarrindast, Mohammad Reza
    Vousooghi, Nasim
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2018, 105 : 103 - 110