Effect of set-up uncertainties on the dose distribution in the match region of supraclavicular and tangential breast fields

被引:22
作者
Idzes, MHM
Holmberg, O
Mijnheer, BJ
Huizenga, K
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, Hosp Dijkzigt, NL-3075 EA Rotterdam, Netherlands
[2] St Lukes Hosp, Dublin, Ireland
[3] Antoni Van Leeuwenhoek Huis, Netherlands Canc Inst, Amsterdam, Netherlands
[4] Univ Nijmegen, Inst Radiotherapy, Nijmegen, Netherlands
关键词
breast irradiation; field matching; film dosimetry; anthropomorphic phantom;
D O I
10.1016/S0167-8140(97)00170-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The objective of this paper is to illustrate the effect of a gap of 5 mm, an overlap of 5 mm and a perfect match on the dose distribution across the junction of tangential breast fields and adjacent supraclavicular and axillary fields. Materials and methods: For this purpose film dosimetry was applied to measure relative dose distributions in two sagittal planes in an anthropomorphic breast phantom having cork lungs, simulating a radiation therapy treatment of the breast and adjacent supraclavicular lymph nodes. Two different treatment techniques, an SSD match technique and a geometrically exact isocentric match technique, as routinely applied in the two institutes were examined. The three-dimensional treatment planning system of each institute was used to calculate the dose distribution In the match region of the supraclavicular fields and the two opposing tangential fields. The measured and calculated dose distributions were evaluated and compared along lines in two sagittal planes from the supraclavicular fields down to the tangential fields crossing the match planes. These dose distributions in the match region were extremely dependent on the set-up of the fields. Results: Although the reproducibility of the film measurements was within 2%, it became clear that the set-up of the fields to achieve a gap of 5 mm, a perfect match or an overlap of 5 mm required a lot of attention, even when using a phantom, Conclusions: It can be concluded that in clinical practice, these set-up difficulties do influence the dose distribution in the match region much more than the systematic uncertainties in the dose calculation algorithms of the treatment planning systems and the type of treatment technique. (C) 1998 Elsevier Science Ireland Ltd.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 8 条
  • [1] IN-VIVO DETERMINATION OF THE ACCURACY OF FIELD MATCHING IN BREAST-CANCER IRRADIATION USING AN ELECTRONIC PORTAL IMAGING DEVICE
    HOLMBERG, O
    HUIZENGA, H
    IDZES, MHM
    LEBESQUE, JV
    VIJLBRIEF, RE
    MIJNHEER, BJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 1994, 33 (02) : 157 - 166
  • [2] EFFECT OF SET-UP ERROR ON THE DOSE ACROSS THE JUNCTION OF MATCHING CRANIAL-SPINAL FIELDS IN THE TREATMENT OF MEDULLOBLASTOMA
    HOLUPKA, EJ
    HUMM, JL
    TARBELL, NJ
    SVENSSON, GK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (02): : 345 - 352
  • [3] MATCHLINE DOSIMETRY OF A 3 FIELD TECHNIQUE FOR BREAST TREATMENT USING COBALT OR 6 MV X-RAYS
    HUNT, MA
    KUTCHER, GJ
    MARTEL, MK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (07): : 1099 - 1106
  • [4] FIELD MATCHING IN BREAST IRRADIATION - AN EXACT SOLUTION TO A GEOMETRICAL PROBLEM
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1986, 5 (01) : 47 - 57
  • [5] 3-FIELD ISOCENTRIC BREAST IRRADIATION USING ASYMMETRIC JAWS AND A TILT BOARD
    MARSHALL, MG
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 28 (03) : 228 - 232
  • [6] A TECHNIQUE FOR TREATING LOCAL BREAST-CANCER USING A SINGLE SET-UP POINT AND ASYMMETRIC COLLIMATION
    ROSENOW, UF
    VALENTINE, ES
    DAVIS, LW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (01): : 183 - 188
  • [7] FILM DOSIMETRY OF CLINICAL ELECTRON-BEAMS
    VANBATTUM, LJ
    HUIZENGA, H
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01): : 69 - 76
  • [8] FILM DOSIMETRY FOR RADIOTHERAPY TREATMENT PLANNING VERIFICATION OF A 6 MV TANGENTIAL BREAST IRRADIATION
    VANBREE, NAM
    IDZES, MHM
    HUIZENGA, H
    MIJNHEER, BJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 1994, 31 (03) : 251 - 255