Impact of oxygen inhalation on the pulmonary circulation - Assessment by magnetic resonance (MR)-perfusion and MR-flow measurements

被引:41
作者
Ley, Sebastian
Puderbach, Michael
Risse, Frank
Ley-Zaporozhan, Julia
Eichingrer, Monika
Takenaka, Daisuke
Kauczor, Hans-Ulrich
Bock, Michael
机构
[1] German Canc Res Ctr, DKFZ, Dept Radiol, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr, DKFZ, Dept Med Phys Radiol, D-69120 Heidelberg, Germany
[3] Univ Heidelberg, Childrens Hosp, Dept Pediat Radiol, D-6900 Heidelberg, Germany
[4] Kobe Univ, Grad Sch Med, Dept Radiol, Kobe, Hyogo, Japan
关键词
hyperoxia; pulmonary blood flow; MRI; perfusion; quantitative; oxygen;
D O I
10.1097/01.rli.0000258655.58753.5d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Oxygen-enhanced magnetic resonance (MR)-ventilation imaging of the lung is based on the inhalation of a high concentration of oxygen (hyperoxia). However, the effect of hyperoxia on the pulmonary circulation is not yet fully understood. In this study the impact of hyperoxia on the pulmonary circulation was evaluated. Materials and Methods: Ten healthy volunteers were examined in a 1.5 T MRI system with contrast-enhanced perfusion MRI (saturation recovery 2D turboFLASH) of the lung and phase-contrast flow measurements in the pulmonary trunk. Both measurements were performed breathing room air (R-A) and, subsequently, 100% oxygen (15 L/mm) (O-2). Results: The perfusion measurements showed a significant difference between RA and 02 for the pulmonary blood flow (181 vs. 257 mL/min/100 mL, P = 0.04) and blood volume (14 vs. 21 mL/100 mL, P = 0.008). The mean transit time of the contrast bolus was not changed (P = 0.4) in the dorsal part of the lung, whereas it was significantly prolonged (P = 0.006) in the central part. The mean heart rate during flow measurements breathing RA (67 +/- 11 beats/min) and O-2 (61 +/- 12 beats/min) were not significantly different (P = 0.055). The average cardiac output (pulmonary trunk) was not significantly lower while breathing O-2 (R-A: 5.9 vs. O-2: 5.5 L/min, P = 0.054). Conclusion: Hyperoxia causes a significant increase and redistribution of the pulmonary perfusion, whereas it leads to a not significant decrease in cardiac output. Thus, for MR-perfusion and MR-flow measurements oxygen inhalation should be avoided, if possible. In the context of oxygen-enhanced MR-ventilation imaging of the lung the contribution of this effect needs to be further evaluated.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 52 条
[21]  
Löffler R, 2000, MAGN RESON MED, V43, P860, DOI 10.1002/1522-2594(200006)43:6<860::AID-MRM12>3.0.CO
[22]  
2-C
[23]  
Lund VE, 1999, ACTA PHYSIOL SCAND, V167, P29
[24]   ON THE THEORY OF THE INDICATOR-DILUTION METHOD FOR MEASUREMENT OF BLOOD FLOW AND VOLUME [J].
MEIER, P ;
ZIERLER, KL .
JOURNAL OF APPLIED PHYSIOLOGY, 1954, 6 (12) :731-744
[25]   Simultaneous cardiac and respiratory synchronization in oxygen-enhanced magnetic resonance imaging of the lung using a pneumotachograph for respiratory monitoring [J].
Molinari, F ;
Gaudino, S ;
Fink, C ;
Corbo, GM ;
Valente, S ;
Pirronti, T ;
Bonomo, L .
INVESTIGATIVE RADIOLOGY, 2006, 41 (05) :476-484
[26]   Assessment of differential pulmonary blood flow using perfusion magnetic resonance imaging - Comparison with radionuclide perfusion scintigraphy [J].
Molinari, Francesco ;
Fink, Christian ;
Risse, Frank ;
Tuengerthal, Siegfried ;
Bonomo, Lorenzo ;
Kauczor, Hans-Ulrich .
INVESTIGATIVE RADIOLOGY, 2006, 41 (08) :624-630
[27]   Quantification of pulmonary blood flow and volume in healthy volunteers by dynamic contrast-enhanced magnetic resonance imaging using a parallel imaging technique [J].
Nikolaou, K ;
Schoenberg, SO ;
Brix, G ;
Goldman, JP ;
Attenberger, U ;
Kuehn, B ;
Dietrich, O ;
Reiser, MF .
INVESTIGATIVE RADIOLOGY, 2004, 39 (09) :537-545
[28]   Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo sequence: improvement of the image quality of oxygen-enhanced MRI [J].
Ohno, Y ;
Hatabu, H ;
Higashino, T ;
Kawamitsu, H ;
Watanabe, H ;
Takenaka, D ;
van Cauteren, M ;
Sugimura, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2004, 52 (02) :200-205
[29]   Quantitative assessment of regional pulmonary perfusion in the entire lung using three-dimensional ultrafast dynamic contrast-enhanced magnetic resonance imaging: Preliminary experience in 40 subjects [J].
Ohno, Y ;
Hatabu, H ;
Murase, K ;
Higashino, T ;
Kawamitsu, H ;
Watanabe, H ;
Takenaka, D ;
Fujii, M ;
Sugimura, K .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (03) :353-365
[30]   Dynamic oxygen-enhanced MRI reflects diffusing capacity of the lung [J].
Ohno, Y ;
Hatabu, H ;
Takenaka, D ;
Van Cauteren, M ;
Fujii, M ;
Sugimura, K .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1139-1144