Preliminary research on body composition measurement using X-ray phase contrast imaging

被引:5
作者
Han, Huajie [1 ,2 ,3 ]
Sharma, Yash [3 ,4 ,5 ]
Zan, Guibin [2 ]
Wu, Zhao [2 ]
Wang, Shenghao [6 ]
Wu, Yanlin [3 ]
Momose, Atsushi [3 ]
Zhai, Chao [7 ]
机构
[1] Univ Sci & Technol China, Dept Precis Machinery & Precis Instrumentat, Hefei 230027, Anhui, Peoples R China
[2] Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Anhui, Peoples R China
[3] Tohoku Univ, Inst Multidisciplinary Res Adv Mat, Sendai, Miyagi 9808577, Japan
[4] Tech Univ Munich, Dept Phys, D-85748 Garching, Germany
[5] Tech Univ Munich, Munich Sch BioEngn, D-85748 Garching, Germany
[6] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Shanghai 201800, Peoples R China
[7] Univ Sci & Technol China, Expt Ctr Engn & Mat Sci, Hefei 230027, Anhui, Peoples R China
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2018年 / 52卷
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
X-ray phase contrast imaging; Talbot-Lau interferometer; Dual-energy absorptiometry; Body composition measurement; TALBOT INTERFEROMETRY; RETRIEVAL METHOD; RADIOGRAPHY; DXA;
D O I
10.1016/j.ejmp.2018.06.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Body composition measurement is of cardinal significance for medical and clinical applications. Currently, the dual-energy X-ray absorptiometry (DEXA) technique is widely applied for this measurement. In this study, we present a novel measurement method using the absorption and phase information obtained simultaneously from the X-ray grating-based interferometer (XGI). Rather than requiring two projection data sets with different X-ray energy spectra, with the proposed method, both the areal densities of the bone and the surrounding soft tissue can be acquired utilizing one projection data set. By using a human body phantom constructed to validate the proposed method, experimental results have shown that the compositions can be calculated with an improved accuracy comparing to the dual energy method, especially for the soft tissue measurement. Since the proposed method can be easily implemented on current XGI setup, it will greatly extend the applications of the XGI, and meanwhile has the potential to be an alternative to DEXA for human body composition measurement.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 37 条
  • [1] Clinical applications of body composition measurements using DXA
    Albanese, CV
    Diessel, E
    Genant, HK
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2003, 6 (02) : 75 - 85
  • [2] Laboratory-based X-ray phase-imaging scanner using Talbot-Lau interferometer for non-destructive testing
    Bachche, Shivaji
    Nonoguchi, Masahiro
    Kato, Koichi
    Kageyama, Masashi
    Koike, Takafumi
    Kuribayashi, Masaru
    Momose, Atsushi
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [3] AN ACCURATE METHOD FOR DIRECT DUAL-ENERGY CALIBRATION AND DECOMPOSITION
    CARDINAL, HN
    FENSTER, A
    [J]. MEDICAL PHYSICS, 1990, 17 (03) : 327 - 341
  • [4] Beam hardening effects in grating-based x-ray phase-contrast imaging
    Chabior, Michael
    Donath, Tilman
    David, Christian
    Bunk, Oliver
    Schuster, Manfred
    Schroer, Christian
    Pfeiffer, Franz
    [J]. MEDICAL PHYSICS, 2011, 38 (03) : 1189 - 1195
  • [5] Diffraction enhanced x-ray imaging
    Chapman, D
    Thomlinson, W
    Johnston, RE
    Washburn, D
    Pisano, E
    Gmur, N
    Zhong, Z
    Menk, R
    Arfelli, F
    Sayers, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) : 2015 - 2025
  • [6] X-RAY IMAGE-CONTRAST FROM A SIMPLE PHASE OBJECT
    DAVIS, TJ
    GUREYEV, TE
    GAO, D
    STEVENSON, AW
    WILKINS, SW
    [J]. PHYSICAL REVIEW LETTERS, 1995, 74 (16) : 3173 - 3176
  • [7] A single-image retrieval method for edge illumination X-ray phase-contrast imaging: Application and noise analysis
    Diemoz, Paul C.
    Vittoria, Fabio A.
    Hagen, Charlotte K.
    Endrizzi, Marco
    Coan, Paola
    Bravin, Alberto
    Wagner, Ulrich H.
    Rau, Christoph
    Robinson, Ian K.
    Olivo, Alessandro
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1759 - 1764
  • [8] In-vivo X-ray Dark-Field Chest Radiography of a Pig
    Gromann, Lukas B.
    De Marco, Fabio
    Willer, Konstantin
    Noel, Peter B.
    Scherer, Kai
    Renger, Bernhard
    Gleich, Bernhard
    Achterhold, Klaus
    Fingerle, Alexander A.
    Muenzel, Daniela
    Auweter, Sigrid
    Hellbach, Katharina
    Reiser, Maximilian
    Baehr, Andrea
    Dmochewitz, Michaela
    Schroeter, Tobias J.
    Koch, Frieder J.
    Meyer, Pascal
    Kunka, Danays
    Mohr, Juergen
    Yaroshenko, Andre
    Maack, Hanns-Ingo
    Pralow, Thomas
    van der Heijden, Hendrik
    Proksa, Roland
    Koehler, Thomas
    Wieberneit, Nataly
    Rindt, Karsten
    Rummeny, Ernst J.
    Pfeiffer, Franz
    Herzen, Julia
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [9] Preliminary research on dual-energy X-ray phase-contrast imaging
    Han, Hua-Jie
    Wang, Sheng-Hao
    Gao, Kun
    Wang, Zhi-Li
    Zhang, Can
    Yang, Meng
    Zhang, Kai
    Zhu, Pei-Ping
    [J]. CHINESE PHYSICS C, 2016, 40 (04)
  • [10] Phase-contrast imaging for body composition measurement
    Han, Huajie
    Hu, Renfang
    Wali, Faiz
    Wu, Zhao
    Gao, Kun
    Wang, Shenghao
    Gu, Yonggang
    Jin, Yi
    Zhai, Chao
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 43 : 25 - 33