In vivo comparison of scanning technique and wavelength in laser Doppler perfusion imaging: measurement in knee ligaments of adult rabbits

被引:24
作者
Forrester, K [1 ]
Doschak, M [1 ]
Bray, R [1 ]
机构
[1] Univ Calgary, Fac Med, McCraig Ctr Joint Injury & Arthrit Res, Calgary, AB T2N 4N1, Canada
基金
英国医学研究理事会;
关键词
blood flow; healing; injury; laser Doppler; ligament; joint; rabbits;
D O I
10.1007/BF02510964
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
At present, there are only two laser Doppler perfusion imaging systems (LDIs) manufactured for medical applications:a 'stepwise' and a 'continuous' scanning LDI. The stepwise scanning LDI has previously been investigated and compared with coloured microsphere determined standardised flow. The continuous scanning LDI is investigated and compared with the stepwise scanning LDI for its ability to measure in vivo, hypoaemic, ligament tissue blood flow changes. The continuous scanning system was supplied with two lasers, red and near infrared (NIR), allowing for additional assessment of the effect of wavelength on imaging ligament perfusion. Perfusion images were obtained from surgically exposed rabbit medial collateral ligaments (MCL). Continuous and stepwise LDI scans were compared using correlation and linear regression analysis of image averages and standard deviations. Using the same method of analysis, LDI measurements using red and NIR lasers indicated a high degree of correlation, at least over the ranges of perfusion assessed, indicating that red and NIR lasers measure similar regions of flow in the rabbit MCL. These experiments confirm that both LDI techniques provide a valid in vivo measure of dynamic changes in connective tissue perfusion and could have significant impact on the understanding and treatment of joint injury and arthritis.
引用
收藏
页码:581 / 586
页数:6
相关论文
共 18 条
  • [1] ANALYSIS OF TISSUE OPTICAL COEFFICIENTS USING AN APPROXIMATE EQUATION VALID FOR COMPARABLE ABSORPTION AND SCATTERING
    ARNFIELD, MR
    MATHEW, RP
    TULIP, J
    MCPHEE, MS
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) : 1219 - 1230
  • [2] COMPARATIVE-STUDY OF 2 LASER DOPPLER BLOOD FLOWMETERS
    BARNETT, NJ
    DOUGHERTY, G
    PETTINGER, SJ
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1990, 14 (06) : 243 - 249
  • [3] Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits
    Bray, R
    Forrester, K
    McDougall, JJ
    Damji, A
    Ferrell, WR
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (03) : 227 - 231
  • [4] BRAY RC, 1995, INT ORTHOP, V3, P39
  • [5] DOSCHAK M, 1994, P CAN ORTHO RES SOC
  • [6] QUANTIFICATION OF THE PERFUSION OF THE ANTERIOR CRUCIATE LIGAMENT AND THE EFFECTS OF STRESS AND INJURY TO SUPPORTING STRUCTURES
    DUNLAP, J
    MCCARTHY, JA
    JOYCE, ME
    OGATA, K
    SHIVELY, RA
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (06) : 808 - 810
  • [7] ESSEX TJH, 1991, J BIOMED ENG, V14, P1898
  • [8] PREDICTION OF SAMPLING DEPTH AND PHOTON PATHLENGTH IN LASER-DOPPLER FLOWMETRY
    JAKOBSSON, A
    NILSSON, GE
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (03) : 301 - 307
  • [9] Kalbfleisch J. G., 1985, PROBABILITY STAT INF, V1
  • [10] Kalbfleisch JG., 1985, Probability and Statistical Inference - Vol. 2, V2