Measurement of standard uptake value in dual-head coincidence system

被引:1
作者
Geng, Jianhua
Chen, Yingmao
Chen, Shengzu
Si, Hongwei
Tian, Jiahe
机构
[1] Gen Hosp PLA, Dept Nucl Med, Beijing 100853, Peoples R China
[2] Chinese Acad Med Sci, Canc Hosp, Dept Nucl Med, Beijing 100021, Peoples R China
关键词
dual-head coincidence imaging system (DHC); standard uptake value (SUV); positron emission tomography (PET);
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The standard uptake value (SUV) is an important semi-quantitative parameter in positron emission tomography (PET). But SUV is not available in dual-head coincidence imaging system (DHC) which is widely used in clinical practice. This study was designed to develop a method for measuring SUV in DHC system, and then compared SUV in DHC and SUV in PET. Method: Firstly, the calibration factor (CF) for converting the voxel count rate to radioactivity concentration was determined by a phantom study in DHC. Then the method for calculating SUV in DHC was formulated. Finally, SUV in DHC and SUV in PET were compared through another phantom study. The phantoms used in the comparing study were cylindrical and consisted of several hot lesions. Results: The CF varied with the detected single count rate in a biquadratic polynomial; the lesion's radioactivity concentration was got based on the CF and the voxel count rate. From the lesion's radioactivity concentration, the lesion's SUV in DHC was obtained. The comparison study showed that SUV in PET was higher than SUV in DHC. The SUV in both DHC and PET increased with increasing sizes of lesions and were related with the reconstruction algorithm. Conclusions: SUV in DHC images could be obtained in our method; the value in DHC images was lower than that in PET image: and many factors, such as system performance, lesion's size, and reconstruction algorithm could influence the SUV accuracy in both DHC and PET.
引用
收藏
页码:219 / 227
页数:9
相关论文
共 18 条
[1]   The clinical value of 18F-FDG detection with a dual-head coincidence camera:: a review [J].
Ak, I ;
Blokland, JAK ;
Pauwels, EKJ ;
Stokkel, MPM .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (06) :763-778
[2]   FDG-PET in differential diagnosis and grading of chondrosarcomas [J].
Aoki, J ;
Watanabe, H ;
Shinozaki, T ;
Tokunaga, M ;
Inoue, T ;
Endo, K .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (04) :603-608
[3]  
Bénard F, 1999, J NUCL MED, V40, P1241
[4]  
Bencherif B, 2004, J NUCL MED, V45, P402
[5]  
Chen CH, 1999, J NUCL MED, V40, P118
[6]  
Chen Ying-mao, 2004, Chinese Journal of Medical Imaging Technology, V20, P99
[7]  
Chen Ying-mao, 2004, Chinese Journal of Medical Imaging Technology, V20, P778
[8]   Viral replication in the nasopharynx is associated with diarrhea in patients with severe acute respiratory syndrome [J].
Cheng, VCC ;
Hung, IFN ;
Tang, BSF ;
Chu, CM ;
Wong, MML ;
Chan, KH ;
Wu, AKL ;
Tse, DMW ;
Chan, KS ;
Zheng, BJ ;
Peiris, JSM ;
Sung, JJY ;
Yuen, KY .
CLINICAL INFECTIOUS DISEASES, 2004, 38 (04) :467-475
[9]   Sarcoma tumor FDG uptake measured by PET and patient outcome: a retrospective analysis [J].
Eary, JF ;
O'Sullivan, F ;
Powitan, Y ;
Chandhury, KR ;
Vernon, C ;
Bruckner, JD ;
Conrad, EU .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (09) :1149-1154
[10]  
Geng JH, 2003, BIO-MED MATER ENG, V13, P181