The results of newborn hearing screening by means of transient otoacoustic emissions - has anything changed over 10 years?

被引:11
作者
Wroblewska-Seniuk, Katarzyna [1 ]
Greczka, Grazyna [2 ]
Dabrowski, Piotr [2 ]
Szyfter, Witold [2 ]
Mazela, Jan [1 ]
机构
[1] Poznan Univ Med Sci, Dept Newborns Infect Dis, Ul Polna 33, PL-60535 Poznan, Poland
[2] Poznan Univ Med Sci, Dept Otolaryngol & Ontol Laryngol, Ul Przybyszewskiego 49, PL-60355 Poznan, Poland
关键词
Hearing screening; Congenital hearing deficit; Hearing loss; Newborn; CURRENT STATE; LANGUAGE; CHILDREN; IDENTIFICATION; KNOWLEDGE; IMPAIRMENT; PROGRAMS; GENETICS;
D O I
10.1016/j.ijporl.2017.02.021
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: Universal newborn hearing screening (UNHS) has become the standard of care in many countries. The aim of this study was to evaluate the results of UNHS after ten years of the program in Poland and to compare them with the results of 2003. Methods: In the study, we analyze the results of UNHS in the University Hospital in Poznan, Poland. Between 01.01.2013 and 31.12.2013, 6827 children were examined by means of otoacoustic emissions. Results: Risk factors (RF) were identified in 772 (11.3%) newborns, which is significantly less than 10 years ago (p < 0.05). The most frequent RF were: ototoxic medications, treatment in neonatal intensive care unit (NICU) and prematurity < 33 weeks of gestation. In 2003, the most frequent were ototoxic medications and prematurity, less frequent was treatment in NICU and more common was low Apgar score. In 51 (6.6%) newborns with RF, the result of OAE was positive either unilaterally or bilaterally. In infants without RF the result was positive unilaterally in 22 (0.4%) and bilaterally in 14 (0.2%) patients. These results are significantly lower than in our former study. The relative risk of positive result was the highest in infants with complex congenital anomalies (RR = 44.99), craniofacial anomalies (RR = 17.46) and mechanical ventilation for > 5 days (RR = 10.69). In our previous study, the highest RR of positive test results was in infants with family history, congenital malformations and low Apgar score. We found that most predictive as to the final diagnosis was bilaterally positive OAE test. In most patients, the second check confirmed the diagnosis, independently of RF. The number of false positive tests at the 1st level of screening is significantly lower now than 10 years ago, probably due to better staff training. Conclusions: Long term monitoring and the appropriate management of hearing deficit in children is essential. UNHS seems to be the most efficient way of finding children who require treatment of hearing impairment. The prevalence of most risk factors of hearing deficit has significantly changed over the years. The number of false positive results has significantly decreased over the years thanks to better staff training. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:4 / 10
页数:7
相关论文
共 44 条
  • [21] Comparison of transient evoked otoacoustic emissions and distortion product otoacoustic emissions when screening hearing in preschool children in a community setting
    Dille, Marilyn
    Glattke, Theodore J.
    Earl, Brian R.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2007, 71 (11) : 1789 - 1795
  • [22] Effects of background noise on recording of portable transient-evoked otoacoustic emission in newborn hearing screening
    Salina, Husain
    Abdullah, Asma
    Mukari, Siti Zamratol Mai-sarah
    Azmi, Mohd Tamil
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2010, 267 (04) : 495 - 499
  • [23] Universal newborn hearing screening and transient evoked otoacoustic emission: new concepts in Brazil
    Chapchap, MJ
    Segre, CM
    SCANDINAVIAN AUDIOLOGY, 2001, 30 : 33 - 36
  • [24] Predicting hearing loss from 10 years of universal newborn hearing screening results and risk factors
    Fitzgibbons, E. Jane
    Driscoll, Carlie
    Myers, Joshua
    Nicholls, Kelly
    Beswick, Rachael
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2021, 60 (12) : 1030 - 1038
  • [25] Universal newborn hearing screening in Mexico:: Results of the first 2 years
    Yee-Arellano, Hector M.
    Leal-Garza, Felicitos
    Pauli-Mueller, Katja
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2006, 70 (11) : 1863 - 1870
  • [26] Early detection of neonatal hearing loss by otoacoustic emissions and auditory brainstem response over 10 years of experience
    Escobar-Ipuz, Fredy A.
    Soria-Bretones, Carmen
    Garcia-Jimenez, Maria A.
    Cueto, Elisa M.
    Torres Aranda, Ana M.
    Mateo Sotos, Jorge
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2019, 127
  • [27] Feasibility of community-based hearing screening using transient evoked otoacoustic emissions
    McPherson, B
    Kei, J
    Smyth, V
    Latham, S
    PUBLIC HEALTH, 1998, 112 (03) : 147 - 152
  • [28] Is Universal Newborn Hearing Screening More Efficient With Auditory Evoked Potentials Compared to Otoacoustic Emissions?
    Granell, Jose
    Gavilanes, Javier
    Herrero, Javier
    Sanchez-Jara, Juan L.
    Velasco, Maria J.
    Martin, Gonzalo
    ACTA OTORRINOLARINGOLOGICA ESPANOLA, 2008, 59 (04): : 170 - 175
  • [29] A comparison of otoacoustic emissions examination results as early hearing screening in normal and infants at risk of hearing loss
    Falerina, Rosa
    Nugroho, Puguh Setyo
    Purnami, Nyilo
    Salsabila, Fatimah Azizah
    BALI MEDICAL JOURNAL, 2023, 12 (02) : 1640 - 1644
  • [30] Hearing screening of infants in Neonatal Unit, Hospital Universiti Sains Malaysia using transient evoked otoacoustic emissions
    Khairi, M
    Suhaimi, SD
    Shahid, H
    Normastura, AR
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2005, 119 (09) : 678 - 683