摘要
Purpose Pressure waveform analysis has the potential for facilitated assessment of pulmonary vein occlusion during cryoballoon ablation for atrial fibrillation. Data on clinical outcomes using this method are lacking. We sought to validate through clinical outcomes the use of pressure waveform analysis as the primary method of determining pulmonary vein occlusion during cryoballoon ablation. Methods A study was performed of 122 consecutive patients with atrial fibrillation (85% paroxysmal) undergoing cryoballoon ablation from May 2014 through July 2015 at a single institution using pressure waveform analysis as the primary method of assessing pulmonary vein occlusion. Results Cryoballoon ablation, with additional segmental radio frequency ablation in 13.7%, resulted in complete pulmonary vein isolation in 100% of patients. The single procedure freedom from recurrence of atrial arrhythmia beyond the initial 3-month post-ablation was 81.2% at a mean follow-up of 237 days. Recurrence of atrial arrhythmia within 3-month post-ablation was 11.1% ,and predicted recurrence beyond 3 months. Repeat ablation was performed in 12.0% of patients. Conclusions In the largest study to date on this topic and the only study to focus on clinical outcomes, pressure waveform analysis as the primary method of determining pulmonary vein occlusion in cryoballoon ablation of atrial fibrillation resulted in acute and long-term procedural success rates comparable to those reported with use of routine pulmonary venography. Controlled study is needed to confirm these findings and to determine if this technique affects variables such as procedure duration and radiation exposure.
引用
收藏
页码:75 / 82
页数:8
相关论文
共 15 条
[1]   Acute and Long-Term Outcomes of Catheter Ablation of Atrial Fibrillation Using the Second-Generation Cryoballoon versus Open-Irrigated Radiofrequency: A Multicenter Experience [J].
Aryana, Arash ;
Singh, Sheldon M. ;
Kowalski, Marcin ;
Pujara, Deep K. ;
Cohen, Andrew I. ;
Singh, Steve K. ;
Aleong, Ryan G. ;
Banker, Rajesh S. ;
Fuenzalida, Charles E. ;
Prager, Nelson A. ;
Bowers, Mark R. ;
D'Avila, Andre ;
O'Neill, Padraig Gearoid .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (08) :832-839
[2]   Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up [J].
Chierchia, Gian-Battista ;
Di Giovanni, Giacomo ;
Ciconte, Giuseppe ;
de Asmundis, Carlo ;
Conte, Giulio ;
Sieira-Moret, Juan ;
Rodriguez-Manero, Moises ;
Casado, Ruben ;
Baltogiannis, Giannis ;
Namdar, Mehdi ;
Saitoh, Yukio ;
Paparella, Gaetano ;
Mugnai, Giacomo ;
Brugada, Pedro .
EUROPACE, 2014, 16 (05) :639-644
[3]   Single 3-minute freeze for second-generation cryoballoon ablation: One-year follow-up after pulmonary vein isolation [J].
Ciconte, Giuseppe ;
de Asmundis, Carlo ;
Sieira, Juan ;
Conte, Giulio ;
Di Giovanni, Giacomo ;
Mugnai, Giacomo ;
Saitoh, Yukio ;
Baltogiannis, Giannis ;
Irfan, Ghazala ;
Coutino-Moreno, Hugo Enrique ;
Hunuk, Burak ;
Velagic, Vedran ;
Brugada, Pedro ;
Chierchia, Gian-Battista .
HEART RHYTHM, 2015, 12 (04) :673-680
[4]   One-Year Follow-Up After Single Procedure Cryoballoon Ablation: A Comparison Between the First and Second Generation Balloon [J].
Di Giovanni, Giacomo ;
Wauters, Kristel ;
Chierchia, Gian-Battista ;
Sieira, Juan ;
Levinstein, Moises ;
Conte, Giulio ;
De Asmundis, Carlo ;
Baltogiannis, Giannis ;
Saitoh, Yukio ;
Ciconte, Giuseppe ;
Julia, Justo ;
Mugnai, Giacomo ;
Irfan, Ghazala ;
Brugada, Pedro .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (08) :834-839
[5]   Improved 1-Year Clinical Success Rate of Pulmonary Vein Isolation with the Second-Generation Cryoballoon in Patients with Paroxysmal Atrial Fibrillation [J].
Fuernkranz, Alexander ;
Bordignon, Stefano ;
Dugo, Daniela ;
Perotta, Laura ;
Gunawardene, Melanie ;
Schulte-Hahn, Britta ;
Nowak, Bernd ;
Schmidt, Boris ;
Chun, Julian K. R. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (08) :840-844
[6]   Two-Year Follow-Up after Contact Force Sensing Radiofrequency Catheter and Second-Generation Cryoballoon Ablation for Paroxysmal Atrial Fibrillation: A Comparative Single Centre Study [J].
Kardos, Attila ;
Kis, Zsuzsanna ;
Som, Zoltan ;
Nagy, Zsofia ;
Foldesi, Csaba .
BIOMED RESEARCH INTERNATIONAL, 2016, 2016
[7]   Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation [J].
Kosmidou, Ioanna ;
Wooden, Shannnon ;
Jones, Brian ;
Deering, Thomas ;
Wickliffe, Andrew ;
Dan, Dan .
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (72) :e50247
[8]  
Kühne M, 2010, SWISS MED WKLY, V140, P214, DOI smw-12977
[9]   One-Year Clinical Outcome After Pulmonary Vein Isolation Using the Second-Generation [J].
Metzner, Andreas ;
Reissmann, Bruno ;
Rausch, Peter ;
Mathew, Shibu ;
Wohlmuth, Peter ;
Tilz, Roland ;
Rillig, Andreas ;
Lemes, Christine ;
Deiss, Sebastian ;
Heeger, Christian ;
Kamioka, Masashi ;
Lin, Tina ;
Ouyang, Feifan ;
Kuck, Karl-Heinz ;
Wissner, Erik .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (02) :288-292
[10]   Pulmonary Vein Isolation Using a Second-Generation Cryoballoon in Patients With Paroxysmal Atrial Fibrillation: One-Year Outcome Using a Single Big-Balloon 3-Minute Freeze Technique [J].
Miyazaki, Shinsuke ;
Hachiya, Hitoshi ;
Nakamura, Hiroaki ;
Taniguchi, Hiroshi ;
Takagi, Takamitsu ;
Hirao, Kenzo ;
Iesaka, Yoshito .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (12) :1375-1380