Contrast enhanced electron beam computed tomography to analyse the coronary arteries in patients after acute myocardial infarction

被引:26
作者
Achenbach, S [1 ]
Ropers, D [1 ]
Regenfus, M [1 ]
Muschiol, G [1 ]
Daniel, WG [1 ]
Moshage, W [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Internal Med 2, D-91054 Erlangen, Germany
关键词
electron beam CT; coronary angiography; myocardial infarction; computed tomography;
D O I
10.1136/heart.84.5.489
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To evaluate the accuracy of contrast enhanced electron beam computed tomography (EBCT) after acute myocardial infarction in determining patency of the infarct related artery and detecting high grade stenoses and occlusions in the coronary vessels. Design-Case study using blinded comparison with invasive coronary angiography. Patients-36 patients (mean age 53 years) 4-70 days after acute myocardial infarction. Interventions-The patients were studied by EBCT and invasive coronary angiography. For EBCT, 50 axial images of the heart (3 mm slice thickness) were acquired. They were triggered by the ECG during breath holding, after intravenous injection of contrast agent. The original images, surface reconstructions, and maximum intensity projections were evaluated for the presence of high grade stenoses and occlusions of the coronary arteries. Main outcome measures-EBCT results were compared with invasive coronary angiography. Results-Of a total of 144 coronary arteries (left main, left anterior descending, left circumflex, and right coronary artery in 36 patients), 29 (20%) were unevaluable by EBCT In the remaining arteries, 33 of 36 high grade lesions were correctly detected (92% sensitivity). Specificity was also 92% (73/79). Patency of the infarct related artery was correctly detected in 15 of 16 cases (94%). Five of the 14 occluded infarct related arteries (35%) were mistaken as stenotic but patent, and six could not be assessed. Conclusions-EBCT is very accurate in detecting significant coronary artery lesions in patients after acute myocardial infarction, but differentiation between occluded and patent infarct related arteries is currently unreliable.
引用
收藏
页码:489 / 493
页数:5
相关论文
共 25 条
  • [1] Comparison of vessel diameters in electron beam tomography and quantitative coronary angiography
    Achenbach, S
    Moshage, W
    Ropers, D
    Bachmann, K
    [J]. INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (01): : 1 - 7
  • [2] Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions
    Achenbach, S
    Moshage, W
    Ropers, D
    Nossen, J
    Daniel, WG
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) : 1964 - 1971
  • [3] Becker C, 1999, ROFO-FORTSCHR RONTG, V170, P99
  • [4] ST-SEGMENT ANALYSIS - A USEFUL MARKER FOR REPERFUSION AFTER THROMBOLYSIS WITH APSAC
    BOSSAERT, L
    CONRAADS, V
    PINTENS, H
    [J]. EUROPEAN HEART JOURNAL, 1991, 12 (03) : 357 - 362
  • [5] PROPOSED DYNAMIC CARDIAC 3-D DENSITOMETER FOR EARLY DETECTION AND EVALUATION OF HEART-DISEASE
    BOYD, DP
    GOULD, RG
    QUINN, JR
    SPARKS, R
    STANLEY, JH
    HERRMANNSFELDT, WB
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) : 2724 - 2726
  • [6] Intravenous three-dimensional coronary angiography using contrast enhanced electron beam computed tomography
    Budoff, MJ
    Oudiz, RJ
    Zalace, CP
    Bakhsheshi, H
    Goldberg, SL
    French, WJ
    Rami, TG
    Brundage, BH
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (06) : 840 - 845
  • [7] Evaluation of electron beam CT coronary angiography in healthy subjects
    Chernoff, DM
    Ritchie, CJ
    Higgins, CB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (01) : 93 - 99
  • [8] *COMM GRAD COR ART, 1975, CIRCULATION S, V51, P5
  • [9] Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography
    Goldfarb, JW
    Edelman, RR
    [J]. RADIOLOGY, 1998, 206 (03) : 830 - 834
  • [10] GOULD RG, 1992, ULTRAFAST COMPUTED T, P1