Wear, debris, and biologic activity of cross-linked polyethylene in the knee - Benefits and potential concerns

被引:121
作者
Fisher, J [1 ]
McEwen, HMJ [1 ]
Tipper, JL [1 ]
Galvin, AL [1 ]
Ingram, J [1 ]
Kamali, A [1 ]
Stone, MH [1 ]
Ingham, E [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1097/01.blo.0000148783.20469.4c
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Cross-linked polyethylene currently is being introduced in knee prostheses. The wear rates, wear debris, and biologic reactivity of non cross-linked, moderately cross-linked, and highly cross-linked polyethylene have been compared in multidirectional wear tests and knee simulators. Multidirectional pin-on-plate wear studies of noncross-linked, moderately cross-linked (5 Mrad), and highly cross-linked (10 Mrad) polyethylene showed a 75% reduction in wear with the highly cross-linked material under kinematics found in the hip, but only a 33% reduction under wear in kinematics representative of the knee. In knee simulator studies, with the fixed-bearing press-fit, condylar Sigma cruciate-retaining knee under high kinematic input conditions, the wear of 5 Mrad moderately cross-linked polyethylene was 13 +/- 4 mm(3) per 1 million cycles, which was lower (p < 0.05) than the wear of clinically used, gamma vacuum foil GUR 1020 polyethylene (23 +/- 6 mm(3)/1 million cycles). For the low-contact stress mobile-bearing knee, the wear of moderately cross-linked polyethylene was 2 1 mm3 per 1 million cycles, which was lower (p < 0.05) than GVF GUR 1020 polyethylene (5 2 mm3/1 million cycles). The wear debris isolated from the fixed-bearing knees showed the moderately crosslinked material had a larger percentage volume of particles smaller than 1 pm in size, compared with GVF GUR 1020 polyethylene. Direct cell culture studies of wear debris generated in sterile wear simulators using multidirectional motion showed a increase (p < 0.05) in tumor necrosis factor-alpha levels and reactivity for GUR 1050 cross-linked poly- ethylene debris compared with an equivalent volume of noncross-linked GUR 1050 polyethylene. The use of crosslinked polyethylene in the knee reduces the volumetric wear rate. However, the clinical significance of reduced fracture toughness, elevated wear in abrasive conditions, and the elevated tumor necrosis factor-alpha release from smaller more reactive particles warrant further investigation.
引用
收藏
页码:114 / 119
页数:6
相关论文
共 17 条
[1]   Investigation of wear of knee prostheses in a new displacement/force-controlled simulator [J].
Barnett, PI ;
McEwen, HMJ ;
Auger, DD ;
Stone, MH ;
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H1) :51-61
[2]   Polyethylene cross-linking by two different methods reduces acetabular liner wear in a hip joint wear simulator [J].
D'Lima, DD ;
Hermida, JC ;
Chen, PC ;
Colwell, CW .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (05) :761-766
[3]   Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses [J].
Endo, M ;
Tipper, JL ;
Barton, DC ;
Stone, MH ;
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H2) :111-122
[4]  
Endo MM, 2001, BIO-MED MATER ENG, V11, P23
[5]   A novel method for the prediction of functional biological activity of polyethylene wear debris [J].
Fisher, J ;
Bell, J ;
Barbour, PSM ;
Tipper, JL ;
Matthews, JB ;
Besong, AA ;
Stone, MH ;
Ingham, E .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H2) :127-132
[6]  
FISHER J, 2004, P 7 WORLD BIOM C, V156, P25
[7]   Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants [J].
Howling, GI ;
Barnett, PI ;
Tipper, JL ;
Stone, MH ;
Fisher, J ;
Ingham, E .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (04) :415-420
[8]   The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles [J].
Ingram, JH ;
Stone, M ;
Fisher, J ;
Ingham, E .
BIOMATERIALS, 2004, 25 (17) :3511-3522
[9]   Properties of crosslinked ultra-high-molecular-weight polyethylene [J].
Lewis, G .
BIOMATERIALS, 2001, 22 (04) :371-401
[10]   Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: A randomized prospective trial [J].
Martell, JM ;
Verner, JJ ;
Incavo, SJ .
JOURNAL OF ARTHROPLASTY, 2003, 18 (07) :55-59