MRI of the coronary vessel wall at 3 T: Comparison of radial and cartesian k-space sampling

被引:10
作者
Bansmann, Paul M.
Priest, Andrew N.
Muellerleile, Kai
Stork, Alexander
Lund, Gunnar K.
Kaul, Michael G.
Adam, Gerhard
机构
[1] Univ Med Ctr Hamburg Eppendorf, Ctr Diagnost Imaging & Intervent, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[2] Cambridge Univ Hosp, NHS Fdn Trust, Dept Med Phys, Cambridge, England
[3] Univ Med Ctr Hamburg Eppendorf, Ctr Diagnost Imaging & Intervent, Dept Cardiol Angiol, Hamburg, Germany
关键词
cardiac imaging; cardiovascular imaging; coronary vessels; heart; MR angiography; MRI;
D O I
10.2214/AJR.06.0266
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to compare the quality of 3D gradient-echo images obtained using radial versus cartesian k-space sampling at 3 T. CONCLUSION. This study shows that the quality of coronary vessel wall imaging of the right coronary artery with radial k-space sampling in 3D turbo field-echo sequences is superior to cartesian k-space sampling at 3 T. Radial k-space sampling at 3 T makes it possible to combine low motion artifact susceptibility with high signal-to-noise ratio.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 30 条
[11]  
Huber ME, 2004, MAGN RESON MED, V52, P221, DOI [10.1002/mrm.20062, 10.1002/MRM.20062]
[12]   Evaluation of balanced steady-state free precession (TrueFISP) and K-space segmented gradient echo sequences for 3D coronary MR angiography with navigator gating at 3 Tesla [J].
Kaul, MG ;
Stork, A ;
Bansmann, PM ;
Nolte-Ernsting, C ;
Lund, GK ;
Weber, C ;
Adam, G .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (11) :1560-1565
[13]   Impact of bulk cardiac motion on right coronary MR angiography and vessel wall Imaging [J].
Kim, WY ;
Stuber, M ;
Kissinger, KV ;
Andersen, NT ;
Manning, WJ ;
Botnar, RM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) :383-390
[14]   Coronary magnetic resonance angiography for the detection of coronary stenoses [J].
Kim, WY ;
Danias, PG ;
Stuber, M ;
Flamm, SD ;
Plein, S ;
Nagel, E ;
Langerak, SE ;
Weber, OM ;
Pedersen, EM ;
Schmidt, M ;
Botnar, RM ;
Manning, WJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (26) :1863-1869
[15]   Coronary artery wall imaging: Initial experience at 3 Tesla [J].
Koktzoglou, I ;
Simonetti, O ;
Li, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) :128-132
[16]   Effects of polar sampling in k-space [J].
Lauzon, ML ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :940-949
[17]   Prospective adaptive navigator correction for breath-hold MR coronary angiography [J].
McConnell, MV ;
Khasgiwala, VC ;
Savord, BJ ;
Chen, MH ;
Chuang, ML ;
Edelman, RR ;
Manning, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) :148-152
[18]   Acceleration of cardiovascular MRI using parallel imaging: Basic principles, practical considerations, clinical applications and future directions [J].
Niendorf, T ;
Sodickson, D .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (01) :15-30
[19]   Magnetic resonance imaging of the coronary vessel wall at 3 T using an obliquely oriented reinversion slab with adiabatic pulses [J].
Priest, AN ;
Bansmann, PM ;
Kaul, MG ;
Stork, A ;
Adam, G .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1115-1122
[20]   ACC AHA guidelines for coronary angiography - A report of the American College of Cardiology American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography) [J].
Scanlon, PJ ;
Faxon, DP ;
Audet, AM ;
Carabello, B ;
Dehmer, GJ ;
Eagle, KA ;
Legako, RD ;
Leon, DF ;
Murray, JA ;
Nissen, SE ;
Pepine, CJ ;
Watson, RM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) :1756-1816