Accuracy of computer-assisted surgery in mandibular reconstruction: A systematic review

被引:82
作者
van Baar, Gustaaf J. C. [1 ]
Forouzanfar, Tymour [1 ]
Liberton, Niels P. T. J. [1 ]
Winters, Henri A. H. [2 ]
Leusink, Frank K. J. [1 ]
机构
[1] Vrije Univ Amsterdam, Dept Oral & Maxillofacial Surg, Oral Pathol & Innovat Lab 3D, Med Ctr,Acad Ctr Dent Amsterdam ACTA, Boelelaan 1117, NL-1081 HV Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Med Ctr, Dept Plast Reconstruct & Hand Surg, Boelelaan 1117, NL-1081 HV Amsterdam, Netherlands
关键词
Oral cancer; Mandibular reconstruction; Free tissue flaps; Surgery; Computer-assisted; Computer-aided design; Computer-aided manufacturing; Printing; Three-dimensional; Data accuracy; Software; FIBULAR FREE-FLAP; GUIDED MAXILLOFACIAL SURGERY; CREST BONE FLAP; VASCULARIZED FIBULA; AIDED-DESIGN; MICROVASCULAR RECONSTRUCTION; SURGICAL GUIDE; HEAD; OUTCOMES; DEFECT;
D O I
10.1016/j.oraloncology.2018.07.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Computer-assisted surgery (CAS) for mandibular reconstruction was developed to improve conventional treatment methods. In the past years, many different software programs have entered the market, offering numerous approaches for preoperative planning and postoperative evaluation of the CAS process of mandibular reconstruction. In this systematic review, we reviewed planning and evaluation methods in studies that quantitatively assessed accuracy of mandibular reconstruction performed with CAS. We included 42 studies describing 413 mandibular reconstructions planned and evaluated using CAS. The commonest software was Proplan/Surgicase CMF (55%). In most cases, the postoperative virtual 3-dimensional model was compared to the preoperative 3-dimensional model, revised to the virtual plan (64%). The commonest landmark for accuracy measurements was the condyle (54%). Accuracy deviations ranged between 0 mm and 12.5 mm and between 0.9 degrees and 17.5 degrees. Because of a lack of uniformity in planning (e.g., image acquisition, mandibular resection size) and evaluation methodologies, the ability to compare postoperative outcomes was limited; meta-analysis was not performed. A practical and simple guideline for standardizing planning and evaluation methods needs to be considered to allow valid comparisons of postoperative results and facilitate meta-analysis in the future.
引用
收藏
页码:52 / 60
页数:9
相关论文
共 79 条
  • [1] Computer-guided rapid-prototyped templates for segmental mandibular osteotomies: a preliminary report
    Abou-ElFetouh, Adel
    Barakat, Ahmed
    Abdel-Ghany, Khaled
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2011, 7 (02) : 187 - 192
  • [2] [Anonymous], INT J ORAL MAXILLOFA
  • [3] [Anonymous], J ORAL MAXILLOFAC SU
  • [4] [Anonymous], J CRANIOMAXILLOFAC S
  • [5] [Anonymous], J ORAL MAXILLOFAC SU
  • [6] [Anonymous], J ORAL MAXILLOFAC SU
  • [7] [Anonymous], 2016, J ORAL MAXIL SURG, DOI DOI 10.1016/J.JOMS.2016.02.021
  • [8] Functional Outcomes of Virtually Planned Free Fibula Flap Reconstruction of the Mandible
    Avraham, Tomer
    Franco, Peter
    Brecht, Lawrence E.
    Ceradini, Daniel J.
    Saadeh, Pierre B.
    Hirsch, David L.
    Levine, Jamie P.
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2014, 134 (04) : 628E - 634E
  • [9] Evaluation of computer-assisted mandibular reconstruction with vascularized iliac crest bone graft compared to conventional surgery: a randomized prospective clinical trial
    Ayoub, Nassim
    Ghassemi, Alireza
    Rana, Majeed
    Gerressen, Marcus
    Riediger, Dieter
    Hoelzle, Frank
    Modabber, Ali
    [J]. TRIALS, 2014, 15
  • [10] Contemporary reconstruction of the mandible
    Bak, Mathew
    Jacobson, Adam S.
    Buchbinder, Daniel
    Urken, Mark L.
    [J]. ORAL ONCOLOGY, 2010, 46 (02) : 71 - 76