Anterior segment optical coherence tomography for imaging the anterior chamber after laser peripheral iridotomy

被引:51
作者
Memarzadeh, Farnaz
Li, Yan
Chopra, Vikas
Varma, Rohit
Francis, Brian A.
Huang, David
机构
[1] Univ So Calif, Doheny Eye Inst, Los Angeles, CA 90033 USA
[2] Univ So Calif, Keck Sch Med, Dept Ophthalmol, Los Angeles, CA 90033 USA
关键词
D O I
10.1016/j.ajo.2006.11.055
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate changes in anterior segment morphology by anterior segment optical coherence tomography (OCT) and gonioscopy before and after laser peripheral iridotomy (LPI). DESIGN: Prospective comparative observational case series. METHODS: Ten eyes of 10 patients with narrow angles were enrolled in the study. Angles were assessed by gonioscopy and anterior segment OCT pre- and post-LPI. The angle opening distance at 500 mu m, angle recess area at 500 mu m and 750 mu m, and trabecular-iris space area at 500 mu m and 750 mu m were compared pre- and post-LPI. RESULTS: The mean gonioscopy grade increased significantly from 0.56 to 2.6 (P > .001). All OCT parameters increased significantly post-LPI. CONCLUSIONS: Changes in the anterior chamber angle morphology post-LPI can be imaged and objectively quantified by anterior segment OCT.
引用
收藏
页码:877 / 879
页数:3
相关论文
共 7 条
[1]   High-speed optical coherence tomography of laser iridotomy [J].
Chalita, MR ;
Li, Y ;
Smith, S ;
Patil, C ;
Westphal, V ;
Rollins, AM ;
Izatt, JA ;
Huang, D .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (06) :1133-1136
[2]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[3]  
Ishikawa H, 2000, Curr Opin Ophthalmol, V11, P133, DOI 10.1097/00055735-200004000-00012
[4]   ULTRASOUND BIOMICROSCOPY OF ANTERIOR SEGMENT STRUCTURES IN NORMAL AND GLAUCOMATOUS EYES [J].
PAVLIN, CJ ;
HARASIEWICZ, K ;
FOSTER, FS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 113 (04) :381-389
[5]   Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles [J].
Radhakrishnan, S ;
Goldsmith, J ;
Huang, D ;
Westphal, V ;
Dueker, DK ;
Rollins, AM ;
Izatt, JA ;
Smith, SD .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (08) :1053-1059
[6]   Real-time optical coherence tomography of the anterior segment at 1310 nm [J].
Radhakrishnan, S ;
Rollins, AM ;
Roth, JE ;
Yazdanfar, S ;
Westphal, V ;
Bardenstein, DS ;
Izatt, JA .
ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (08) :1179-1185
[7]  
SHAFFER R N, 1960, Trans Am Acad Ophthalmol Otolaryngol, V64, P112