Analysis of torque and force with differently tapered rotary endodontic instruments in vitro

被引:71
作者
Schrader, C
Peters, OA
机构
[1] Univ Zurich, Clin Prevent Dent Cariol Periodontol & Endodontol, CH-8028 Zurich, Switzerland
[2] Univ Calif San Francisco, Dept Prevent & Restorat Dent Sci, Endodont Div, San Francisco, CA 94143 USA
关键词
D O I
10.1097/01.don.0000137634.20499.1d
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to compare torques and forces developed by two sequences of nickel-titanium rotary instruments, using only .04 taper instruments or a combination of .04 and .06 tapers, respectively. Curved canals in plastic blocks were shaped in a torque-testing device; torque, force, contact areas and numbers of working rotations were determined. Analysis of variance and Pearson correlation coefficients were used to compare the two sequences. Mean torque ranged from 0.2 +/- 0.03 to 3.19 +/- 0.28 Ncm and was higher for instrument sizes 25 to 45 in group A. Mean vertical forces ranged from 1.49 +/- 0.54 to 12.0 +/- 3.5 N; there were significant correlations between torque and force as well as between torque and contact areas. Numbers of rotations were lower in the combined .04 and .06 sequence. An instrumentation sequence encompassing various tapers seems to be safer regarding torsional and fatigue failure compared to a sequence that used one single taper. However, the former sequence requires the use of more instruments.
引用
收藏
页码:120 / 123
页数:4
相关论文
共 24 条
[1]   The 'Lightspeed' preparation technique evaluated by Swiss clinicians after attending continuing education courses [J].
Barbakow, F ;
Lutz, F .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :46-50
[2]   Location of contact areas on rotary Profile® instruments in relationship to the forces developed during mechanical preparation on extracted teeth [J].
Blum, JY ;
Machtou, P ;
Micallef, JP .
INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (02) :108-114
[3]   Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments: Value of the safety quotient [J].
Blum, JY ;
Machtou, P ;
Ruddle, C ;
Micallef, JP .
JOURNAL OF ENDODONTICS, 2003, 29 (09) :567-575
[4]  
Bryant ST, 1998, INT ENDOD J, V31, P275
[5]  
Bryant ST, 1998, INT ENDOD J, V31, P282
[6]   Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments [J].
Haïkel, Y ;
Serfaty, R ;
Bateman, G ;
Senger, B ;
Allemann, C .
JOURNAL OF ENDODONTICS, 1999, 25 (06) :434-440
[7]   Root canal preparation with FlexMaster:: asessment of torque and force in relation to canal anatomy [J].
Hübscher, W ;
Barbakow, F ;
Peters, OA .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (12) :883-890
[8]   Comparison of apical transportation in four Ni-Ti rotary instrumentation techniques [J].
Iqbal, MK ;
Maggiore, F ;
Suh, B ;
Edwards, KR ;
Kang, J ;
Kim, SC ;
Phil, M .
JOURNAL OF ENDODONTICS, 2003, 29 (09) :587-591
[9]   Rotary Ni-Ti profile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage [J].
Mandel, E ;
Adib-Yazdi, M ;
Benhamou, LM ;
Lachkar, T ;
Mesgouez, C ;
Sobel, M .
INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (06) :436-443
[10]   Influence of operator experience on canal preparation time when using the rotary Ni-Ti ProFile system in simulated curved canals [J].
Mesgouez, C ;
Rilliard, F ;
Matossian, L ;
Nassiri, K ;
Mandel, E .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (03) :161-165