Audit feasibility for geometric distortion in magnetic resonance imaging for radiotherapy

被引:9
作者
Alzahrani, Meshal [1 ,2 ]
Broadbent, David A. [3 ]
Chuter, Robert [4 ,5 ]
Al-Qaisieh, Bashar [3 ]
Jackson, Steven [4 ]
Michael, Hutton [4 ]
Johnstone, Robert, I [6 ]
Shah, Simon [6 ]
Wetscherek, Andreas [7 ,8 ]
Chick, H. Joan [7 ,8 ]
Wyatt, Jonathan J. [9 ,10 ]
McCallum, Hazel Mhairi [9 ,10 ]
Speight, Richard [3 ]
机构
[1] King Abdulaziz Univ, Fac Appl Med Sci, Dept Diagnost Radiol, Jeddah, Saudi Arabia
[2] Univ Leeds, Leeds Inst Cardiovasc & Metab Med, Biomed Imaging Sci Dept, Leeds, W Yorkshire, England
[3] Leeds Teaching Hosp NHS Trust, Dept Med Phys & Engn, Leeds, W Yorkshire, England
[4] Christie NHS Fdn Trust, Christie Med Phys & Engn CMPE, Manchester, Lancs, England
[5] Univ Manchester, Fac Biol Med & Hlth, Div Canc Sci, Manchester, Lancs, England
[6] Guys & St Thomas NHS Fdn Trust, London, England
[7] Inst Canc Res, Joint Dept Phys, London, England
[8] Royal Marsden NHS Fdn Trust, London, England
[9] Newcastle Upon Tyne Hosp NHS Fdn Trust, Northern Ctr Canc Care, Newcastle Upon Tyne, Tyne & Wear, England
[10] Newcastle Univ, Ctr Canc, Newcastle Upon Tyne, Tyne & Wear, England
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2020年 / 15卷
关键词
Magnetic resonance imaging; Geometric distortion; Radiotherapy; Quality assurance; Audit; RADIATION-THERAPY; MRI; PRECISION; ACCURACY; IMPACT;
D O I
10.1016/j.phro.2020.07.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Magnetic Resonance Imaging (MRI) is increasingly being used in radiotherapy (RT). However, geometric distortions are a known challenge of using MRI in RT. The aim of this study was to demonstrate feasibility of a national audit of MRI geometric distortions. This was achieved by assessing large field of view (FOV) MRI distortions on a number of scanners used clinically for RT. Materials and methods: MRI scans of a large FOV MRI geometric distortion phantom were acquired on 11 MRI scanners that are used clinically for RT in the UK. The mean and maximum distortions and variance between scanners were reported at different distances from the isocentre. Results: For a small FOV representing a brain (100-150 mm from isocentre) all distortions were < 2 mm except for the maximum distortion of one scanner. For a large FOV representing a head and neck/pelvis (200-250 mm from isocentre) mean distortions were < 2 mm except for one scanner, maximum distortions were > 10 mm in some cases. The variance between scanners was low and was found to increase with distance from isocentre. Conclusions: This study demonstrated feasibility of the technique to be repeated in a country wide geometric distortion audit of all MRI scanners used clinically for RT. Recommendations were made for performing such an audit and how to derive acceptable limits of distortion in such an audit.
引用
收藏
页码:80 / 84
页数:5
相关论文
共 50 条
  • [41] An audit of magnetic resonance imaging (MRI) anaesthesia
    Wilson, D
    Laurence, AS
    Bunting, P
    Keens, SJ
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (03) : 466P - 466P
  • [42] Magnetic resonance spectroscopy imaging in radiotherapy planning for recurrent glioma
    Ballangrud, Ase M.
    Lymberis, Stella
    Thakur, Sunitha B.
    Karimi, Sasan
    Huang, Wei
    Abrey, Lauren E.
    Beal, Kathryn
    Iwamoto, Fabio M.
    Brennan, Cameron
    Gutin, Philip H.
    Chang, Jenghwa
    MEDICAL PHYSICS, 2011, 38 (05) : 2724 - 2730
  • [43] Feasibility of using contrast-free quantitative magnetic resonance imaging for liver sparing stereotactic ablative body radiotherapy
    Brewster, Frank
    Middleton, Zoe
    McWilliam, Alan
    Brocklehurst, Andrew
    Radhakrishna, Ganesh
    Chuter, Robert
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2024, 49
  • [44] Feasibility of Dobutamine Stress Cardiovascular Magnetic Resonance Imaging in Children
    Strigl, Sebastian
    Beroukhim, Rebecca
    Valente, Anne Marie
    Annese, David
    Harrington, James S.
    Geva, Tal
    Powell, Andrew J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) : 313 - 319
  • [45] Clinical application of diffusion-weighted magnetic resonance imaging in radiotherapy for nasopharyngeal carcinoma
    Xu, Jifei
    Zhang, Kun
    Wang, Hongyan
    Cui, Zhenzhen
    Wu, Yi
    Wang, Wanqin
    Wang, Fan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (02) : 297 - 306
  • [46] Diffusion-Sensitized Ophthalmic Magnetic Resonance Imaging Free of Geometric Distortion at 3.0 and 7.0 T A Feasibility Study in Healthy Subjects and Patients With Intraocular Masses
    Paul, Katharina
    Graessl, Andreas
    Rieger, Jan
    Lysiak, Darius
    Huelnhagen, Till
    Winter, Lukas
    Heidemann, Robin
    Lindner, Tobias
    Hadlich, Stefan
    Zimpfer, Annette
    Pohlmann, Andreas
    Endemann, Beate
    Krueger, Paul-Christian
    Langner, Soenke
    Stachs, Oliver
    Niendorf, Thoralf
    INVESTIGATIVE RADIOLOGY, 2015, 50 (05) : 309 - 321
  • [47] Task group 284 report: magnetic resonance imaging simulation in radiotherapy: considerations for clinical implementation, optimization, and quality assurance
    Glide-Hurst, Carri K.
    Paulson, Eric S.
    McGee, Kiaran
    Tyagi, Neelam
    Hu, Yanle
    Balter, James
    Bayouth, John
    MEDICAL PHYSICS, 2021, 48 (07) : E636 - E670
  • [48] Magnetic resonance imaging for prostate cancer radiotherapy
    Dinh, Cuong V.
    Steenbergen, Peter
    Ghobadi, Ghazaleh
    Heijmink, Stijn W. T. J. P.
    Pos, Floris J.
    Haustermans, Karin
    van der Heide, Uulke A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (03): : 446 - 451
  • [49] An audit of preoperative magnetic resonance imaging staging of the breast
    Bagnall, M.
    Turnbull, A. E.
    BREAST CANCER RESEARCH, 2006, 8 (Suppl 1) : S9 - S9
  • [50] Magnetic Resonance Imaging of Rectal and Anal Cancer
    Torkzad, Michael R.
    Kamel, Ihab
    Halappa, Vivek Gowdra
    Beets-Tan, Regina G. H.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2014, 22 (01) : 85 - +