Audit feasibility for geometric distortion in magnetic resonance imaging for radiotherapy

被引:9
作者
Alzahrani, Meshal [1 ,2 ]
Broadbent, David A. [3 ]
Chuter, Robert [4 ,5 ]
Al-Qaisieh, Bashar [3 ]
Jackson, Steven [4 ]
Michael, Hutton [4 ]
Johnstone, Robert, I [6 ]
Shah, Simon [6 ]
Wetscherek, Andreas [7 ,8 ]
Chick, H. Joan [7 ,8 ]
Wyatt, Jonathan J. [9 ,10 ]
McCallum, Hazel Mhairi [9 ,10 ]
Speight, Richard [3 ]
机构
[1] King Abdulaziz Univ, Fac Appl Med Sci, Dept Diagnost Radiol, Jeddah, Saudi Arabia
[2] Univ Leeds, Leeds Inst Cardiovasc & Metab Med, Biomed Imaging Sci Dept, Leeds, W Yorkshire, England
[3] Leeds Teaching Hosp NHS Trust, Dept Med Phys & Engn, Leeds, W Yorkshire, England
[4] Christie NHS Fdn Trust, Christie Med Phys & Engn CMPE, Manchester, Lancs, England
[5] Univ Manchester, Fac Biol Med & Hlth, Div Canc Sci, Manchester, Lancs, England
[6] Guys & St Thomas NHS Fdn Trust, London, England
[7] Inst Canc Res, Joint Dept Phys, London, England
[8] Royal Marsden NHS Fdn Trust, London, England
[9] Newcastle Upon Tyne Hosp NHS Fdn Trust, Northern Ctr Canc Care, Newcastle Upon Tyne, Tyne & Wear, England
[10] Newcastle Univ, Ctr Canc, Newcastle Upon Tyne, Tyne & Wear, England
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2020年 / 15卷
关键词
Magnetic resonance imaging; Geometric distortion; Radiotherapy; Quality assurance; Audit; RADIATION-THERAPY; MRI; PRECISION; ACCURACY; IMPACT;
D O I
10.1016/j.phro.2020.07.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Magnetic Resonance Imaging (MRI) is increasingly being used in radiotherapy (RT). However, geometric distortions are a known challenge of using MRI in RT. The aim of this study was to demonstrate feasibility of a national audit of MRI geometric distortions. This was achieved by assessing large field of view (FOV) MRI distortions on a number of scanners used clinically for RT. Materials and methods: MRI scans of a large FOV MRI geometric distortion phantom were acquired on 11 MRI scanners that are used clinically for RT in the UK. The mean and maximum distortions and variance between scanners were reported at different distances from the isocentre. Results: For a small FOV representing a brain (100-150 mm from isocentre) all distortions were < 2 mm except for the maximum distortion of one scanner. For a large FOV representing a head and neck/pelvis (200-250 mm from isocentre) mean distortions were < 2 mm except for one scanner, maximum distortions were > 10 mm in some cases. The variance between scanners was low and was found to increase with distance from isocentre. Conclusions: This study demonstrated feasibility of the technique to be repeated in a country wide geometric distortion audit of all MRI scanners used clinically for RT. Recommendations were made for performing such an audit and how to derive acceptable limits of distortion in such an audit.
引用
收藏
页码:80 / 84
页数:5
相关论文
共 50 条
  • [21] Evaluating the accuracy of geometrical distortion correction of magnetic resonance images for use in intracranial brain tumor radiotherapy
    Bagherimofidi, Seyed Mehdi
    Yang, Claus Chunli
    Rey-Dios, Roberto
    Kanakamedala, Madhava R.
    Fatemi, Ali
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (06) : 606 - 613
  • [22] Planning feasibility of extremely hypofractionated prostate radiotherapy on a 1.5 T magnetic resonance imaging guided linear accelerator
    den Hartogh, Mariska D.
    de Boer, Hans C. J.
    De Groot-van Breugel, Eline N.
    van Zyp, Jochem R. N. van der Voort
    Hes, Jochem
    van der Heide, Uulke A.
    Pos, Floris
    Haustermans, Karin
    Depuydt, Tom
    Smeenk, Robert Jan
    Kunze-Busch, Martina
    Raaymakers, Bas W.
    Kerkmeijer, Linda G. W.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2019, 11 : 16 - 20
  • [23] Magnetic resonance imaging in glioblastoma radiotherapy - beyond treatment adaptation
    Paczona, Viktor R.
    Vegvary, Zoltan
    Kelemen, Gyongyi
    Dobi, Agnes
    Borzasi, Emoke
    Varga, Linda
    Cserhati, Adrienne
    Csomor, Angela
    Radics, Bence
    Dosa, Sandor
    Balazsfi, Marton
    Fodor, Emese
    Borzak, Ferenc
    Puskas, Arpad
    Varga, Zoltan
    Olah, Judit
    Hideghety, Katalin
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2025, 34
  • [24] An Anthropomorphic Head Phantom Prototype for the Measurement of Geometric Distortion in Magnetic Resonance Imaging System
    Shurche, Sadegh
    Sooteh, Mohammad Yousefi
    Iranian Journal of Medical Physics, 2024, 21 (01) : 53 - 63
  • [25] Distortion inherent to magnetic resonance imaging can lead to geometric miss in radiosurgery planning
    Seibert, Tyler M.
    White, Nathan S.
    Kim, Gwe-Ya
    Moiseenko, Vitali
    McDonald, Carrie R.
    Farid, Nikdokht
    Bartsch, Hauke
    Kuperman, Joshua
    Karunamuni, Roshan
    Marshall, Deborah
    Holland, Dominic
    Sanghvi, Parag
    Simpson, Daniel R.
    Mundt, Arno J.
    Dale, Anders M.
    Hattangadi-Gluth, Jona A.
    PRACTICAL RADIATION ONCOLOGY, 2016, 6 (06) : E319 - E328
  • [26] Evaluation of system-related magnetic resonance imaging geometric distortion in radiation therapy treatment planning: two approaches and effectiveness of three-dimensional distortion correction
    Kato, Yutaka
    Okudaira, Kuniyasu
    Kamomae, Takeshi
    Kumagai, Motoki
    Nagai, Youta
    Taoka, Toshiaki
    Itoh, Yoshiyuki
    Naganawa, Shinji
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2022, 84 (01): : 29 - 41
  • [27] Introducing magnetic resonance imaging into the lung cancer radiotherapy workflow - An assessment of patient experience
    Bellhouse, S.
    Brown, S.
    Dubec, M.
    Taylor, S.
    Hales, R.
    Whiteside, L.
    Yorke, J.
    Faivre-Finn, C.
    RADIOGRAPHY, 2021, 27 (01) : 14 - 23
  • [28] Accuracy of multiparametric magnetic resonance imaging in detecting recurrent prostate cancer after radiotherapy
    Arumainayagam, Nimalan
    Kumaar, Senthil
    Ahmed, Hashim U.
    Moore, Caroline M.
    Payne, Heather
    Freeman, Alex
    Allen, Clare
    Kirkham, Alex
    Emberton, Mark
    BJU INTERNATIONAL, 2010, 106 (07) : 991 - 997
  • [29] Characterization of 3D geometric distortion of magnetic resonance imaging scanners commissioned for radiation therapy planning
    Torfeh, Tarraf
    Hammoud, Rabih
    Perkins, Gregory
    McGarry, Maeve
    Aouadi, Souha
    Celik, Azim
    Hwang, Ken-Pin
    Stancanello, Joseph
    Petric, Primoz
    Al-Hammadi, Noora
    MAGNETIC RESONANCE IMAGING, 2016, 34 (05) : 645 - 653
  • [30] A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging
    Wang, DM
    Doddrell, DM
    Cowin, G
    MAGNETIC RESONANCE IMAGING, 2004, 22 (04) : 529 - 542