SHAKING TABLE TEST OF A COMPLEX LONG-SPAN CONNECTED BUILDING

被引:0
|
作者
Wu, Pei-Feng [1 ]
Ji, Jing [1 ]
Chen, Xue-Wei [1 ]
Han, Xiao-Lei [1 ]
机构
[1] S China Univ Technol, Tall Bldg Struct Res Inst, Guangzhou 510640, Peoples R China
来源
ISISS '2009: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2 | 2009年
关键词
long-; span; connected structure; simulated earthquake; shaking table test;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
For commercial or aesthetic purposes, the high- rise buildings are becoming increasingly unique and complicate in shapes. Zhongzhou sightseeing gate in Guangzhou, consisted of two towers connected by a lone- span corridor, belongs to such a high- rise building. The great irregularity in plan and elevation, according to Chinese code, necessitates a detailed study, which usually includes refined structural analysis, scaled structural model test and large size member or joint test. In order to investigate the seismic performance of this complex long- span connected building, the shaking table test of the 1:30- scale structural model was performed on the shaking table with three-dimensions and six degrees- of-freedom. Based on the test, the self-shaking properties. seismic responses and damage features are presented, which shows that the structure exhibits satisfactory seismic performance under the action of 7- and 8- occurred earthquakes.
引用
收藏
页码:1481 / 1485
页数:5
相关论文
共 50 条
  • [11] Shaking table test on stagger transfer structure in tall building
    Wu, Bo
    Shen, Chao-Yong
    Zhou, Fu-Lin
    Huang, Xiang-Yun
    Chen, Jian-Qiu
    Luo, Xue-Hai
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 1383 - 1390
  • [12] Shaking table test of structure with discretely connected precast RC diaphragm
    Pang R.
    Sun Y.
    Xu Z.
    Gao C.
    Yang J.
    Zhang P.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (05): : 125 - 136
  • [13] Experimental Instruments and Results' Analysis of a Shaking Table Model Test for a Complex High-rise Building
    Chen, Yue
    CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 1475 - 1479
  • [14] Shaking table test of high-level isolation connected structure with gap damper device
    Lü Q.
    Lu W.
    Fu B.
    Xiong Y.
    Qian W.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2024, 45 (04): : 12 - 23
  • [15] Design and shaking table test of a ten-storey building with steel plate shear walls partially connected to columns
    Feng, Liqiang
    Li, Feng
    Niu, Changlin
    Wei, Hongliang
    Ji, Shuyan
    Yang, Pu
    Wang, Guojue
    JOURNAL OF BUILDING ENGINEERING, 2022, 49
  • [16] Shaking table test on a full scale URM cavity wall building
    F. Graziotti
    U. Tomassetti
    S. Kallioras
    A. Penna
    G. Magenes
    Bulletin of Earthquake Engineering, 2017, 15 : 5329 - 5364
  • [17] Shaking table test on a full scale URM cavity wall building
    Graziotti, F.
    Tomassetti, U.
    Kallioras, S.
    Penna, A.
    Magenes, G.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2017, 15 (12) : 5329 - 5364
  • [18] Shaking table test on insulated sandwich concrete wall building structure
    Qiao, Wentao
    Kane, Jialing
    Wang, Dong
    Yuan, Jiawei
    Wang, Zexiong
    JOURNAL OF BUILDING ENGINEERING, 2021, 37 (37):
  • [19] Torsion response of reinforced concrete building under shaking table test
    Dai, JW
    Wong, YL
    Zhang, MZ
    ADVANCES IN STRUCTURAL DYNAMICS, VOLS I & II, 2000, 10 : 859 - 866
  • [20] Research on Shaking Table Test of Masonry Building with Rowlock Cavity walls
    Chen, Zhongfan
    Lu, Fei
    Yuan, Yang
    Miao, Shasha
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 1196 - 1205