Quantification of metabolites in dried blood spots by direct infusion high resolution mass spectrometry

被引:32
作者
de Sain-van der Velden, Monique G. M. [1 ]
van der Ham, Maria
Gerrits, Johan
Prinsen, Hubertus C. M. T.
Willemsen, Marcel
Pras-Raves, Mia L.
Jans, Judith J.
Verhoeven-Duif, Nanda M.
机构
[1] UMC Utrecht, Dept Genet, KC 02-069-1,POB 85090, NL-3508 AB Utrecht, Netherlands
关键词
Dried blood spot; High resolution mass spectrometry; Direct infusion; CREATINE; PLASMA;
D O I
10.1016/j.aca.2017.04.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Diagnosis and treatment of inborn errors of metabolism (IEM) require the analysis of a variety of metabolites. These compounds are usually quantified by targeted platforms. High resolution mass spectrometry (HRMS) has the potential to detect hundreds to thousands of metabolites simultaneously. A chip-based nanoelectrospray source (chip-based nanoESI) enables the direct infusion of biological samples. Major advantages of this system include high sample throughput, no sample carryover, and low sample consumption. The combination, chip-based nanoESI-HRMS enables untargeted metabolomics of biological samples but its potential for quantification of metabolites has not been reported. We investigated whether chip-based nanoESI-HRMS is suitable for quantification of metabolites in dried blood spots (DBS). After addition of internal standards, metabolites were extracted with methanol. Aliquots of each extract were analysed by chip-based nanoESI-HRMS operating in both positive and negative mode with an m/z window of 70-600 and a resolution of 140,000. Total run time was 4.5 min per sample and a full report could be generated within 40 min. Concentrations of all 21 investigated diagnostic metabolites in DBS as quantified by chip-based nanoESI-HRMS correlated well with those obtained by targeted liquid chromatography-tandem mass spectrometry. We conclude that chip-based nanoESI-HRMS is suitable for quantification. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 50 条
  • [41] A rapid liquid chromatography tandem mass spectrometry-based method for measuring propranolol on dried blood spots
    Della Bona, Maria Luisa
    Malvagia, Sabrina
    Villanelli, Fabio
    Giocaliere, Elisa
    Ombrone, Daniela
    Funghini, Silvia
    Filippi, Luca
    Cavallaro, Giacomo
    Bagnoli, Paola
    Guerrini, Renzo
    la Marca, Giancarlo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 78-79 : 34 - 38
  • [42] A simplified method for bortezomib determination using dried blood spots in combination with liquid chromatography/tandem mass spectrometry
    Guo, Zi-Xuan
    Yang, Fan
    van den Anker, Johannes N.
    Zheng, Yi
    Zhao, Wei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1181
  • [43] Can dried blood spots be used to accurately measure vitamin D metabolites?
    Binks, Michael J.
    Bleakley, Amy S.
    Rathnayake, Geetha
    Pizzutto, Susan
    Chang, Anne B.
    McWhinney, Brett
    Ungerer, Jacobus
    CLINICA CHIMICA ACTA, 2021, 518 : 70 - 77
  • [44] Towards newborn screening for ornithine transcarbamylase deficiency: Fast non-chromatographic orotic acid quantification from dried blood spots by tandem mass spectrometry
    Janzen, Nils
    Terhardt, Michael
    Sander, Stefanie
    Demirkol, Mubeccel
    Gokcay, Gulden
    Peter, Michael
    Luecke, Thomas
    Sander, Johannes
    Das, Anibh M.
    CLINICA CHIMICA ACTA, 2014, 430 : 28 - 32
  • [45] Multiplex Assay for Quantification of Acute Phase Proteins and Immunoglobulin A in Dried Blood Spots
    Vidova, Veronika
    Stuchlikova, Eliska
    Vrbova, Marketa
    Almasi, Martina
    Klanova, Jana
    Thon, Vojtech
    Spacil, Zdenek
    JOURNAL OF PROTEOME RESEARCH, 2019, 18 (01) : 380 - 391
  • [46] Recent advances in high-throughput biofluid metabotyping by direct infusion and ambient ionization mass spectrometry
    Plekhova, Vera
    De Windt, Kimberly
    De Spiegeleer, Margot
    De Graeve, Marilyn
    Vanhaecke, Lynn
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2023, 168
  • [47] Determination of Cyclohexylmethylfluorophosphonate Metabolites in Human Blood Plasma Using High-Resolution Liquid Chromatography-Mass Spectrometry
    Braun, A., V
    Stavitskaya, Ya, V
    Baigil'diev, T. M.
    Oreshkin, D., V
    Rybal'chenko, I., V
    Rodin, I. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (06) : 783 - 791
  • [48] Oligonucleotide quantification and metabolite profiling by high-resolution and accurate mass spectrometry
    Liu, Ju
    Li, Jing
    Tran, Chris
    Aluri, Krishna
    Zhang, Xuemei
    Clausen, Valerie
    Zlatev, Ivan
    Guan, Lihua
    Chong, Saeho
    Charisse, Klaus
    Wu, Jing-Tao
    Najarian, Diana
    Xu, Yuanxin
    BIOANALYSIS, 2019, 11 (21) : 1967 - 1980
  • [49] Quantification of steroid hormones in human serum by liquid chromatography-high resolution tandem mass spectrometry
    Matysik, Silke
    Liebisch, Gerhard
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1526 : 112 - 118
  • [50] Evaluation of Direct Infusion-Multiple Reaction Monitoring Mass Spectrometry for Quantification of Heat Shock Proteins
    Xiang, Yun
    Koomen, John M.
    ANALYTICAL CHEMISTRY, 2012, 84 (04) : 1981 - 1986