Quantification of metabolites in dried blood spots by direct infusion high resolution mass spectrometry

被引:32
作者
de Sain-van der Velden, Monique G. M. [1 ]
van der Ham, Maria
Gerrits, Johan
Prinsen, Hubertus C. M. T.
Willemsen, Marcel
Pras-Raves, Mia L.
Jans, Judith J.
Verhoeven-Duif, Nanda M.
机构
[1] UMC Utrecht, Dept Genet, KC 02-069-1,POB 85090, NL-3508 AB Utrecht, Netherlands
关键词
Dried blood spot; High resolution mass spectrometry; Direct infusion; CREATINE; PLASMA;
D O I
10.1016/j.aca.2017.04.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Diagnosis and treatment of inborn errors of metabolism (IEM) require the analysis of a variety of metabolites. These compounds are usually quantified by targeted platforms. High resolution mass spectrometry (HRMS) has the potential to detect hundreds to thousands of metabolites simultaneously. A chip-based nanoelectrospray source (chip-based nanoESI) enables the direct infusion of biological samples. Major advantages of this system include high sample throughput, no sample carryover, and low sample consumption. The combination, chip-based nanoESI-HRMS enables untargeted metabolomics of biological samples but its potential for quantification of metabolites has not been reported. We investigated whether chip-based nanoESI-HRMS is suitable for quantification of metabolites in dried blood spots (DBS). After addition of internal standards, metabolites were extracted with methanol. Aliquots of each extract were analysed by chip-based nanoESI-HRMS operating in both positive and negative mode with an m/z window of 70-600 and a resolution of 140,000. Total run time was 4.5 min per sample and a full report could be generated within 40 min. Concentrations of all 21 investigated diagnostic metabolites in DBS as quantified by chip-based nanoESI-HRMS correlated well with those obtained by targeted liquid chromatography-tandem mass spectrometry. We conclude that chip-based nanoESI-HRMS is suitable for quantification. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 13 条
[1]   Analysis of guanidinoacetate and creatine by isotope dilution electrospray tandem mass spectrometry [J].
Bodamer, OA ;
Bloesch, SM ;
Gregg, AR ;
Stockler-Ipsiroglu, S ;
O'Brien, WE .
CLINICA CHIMICA ACTA, 2001, 308 (1-2) :173-178
[2]   Differences between acylcarnitine profiles in plasma and bloodspots [J].
de Sain-van der Velden, Monique G. M. ;
Diekman, Eugene F. ;
Jans, Judith J. ;
van der Ham, Maria ;
Prinsen, Berthil H. C. M. T. ;
Visser, Gepke ;
Verhoeven-Duif, Nanda M. .
MOLECULAR GENETICS AND METABOLISM, 2013, 110 (1-2) :116-121
[3]   Metabonomics of Newborn Screening Dried Blood Spot Samples: A Novel Approach in the Screening and Diagnostics of Inborn Errors of Metabolism [J].
Denes, Julia ;
Szabo, Eszter ;
Robinette, Steven L. ;
Szatmari, Ildiko ;
Szonyi, Laszlo ;
Kreuder, Joachim G. ;
Rauterberg, Ernst W. ;
Takats, Zoltan .
ANALYTICAL CHEMISTRY, 2012, 84 (22) :10113-10120
[4]   Development and validation of a quantitative assay based on tandem mass spectrometry [J].
Honour, John W. .
ANNALS OF CLINICAL BIOCHEMISTRY, 2011, 48 :97-111
[5]   Semi-targeted residue screening in complex matrices with liquid chromatography coupled to high resolution mass spectrometry: current possibilities and limitations [J].
Kaufmann, Anton ;
Butcher, Patrick ;
Maden, Kathryn ;
Walker, Stephan ;
Widmer, Miryam .
ANALYST, 2011, 136 (09) :1898-1909
[6]   Fully automated liquid extraction-based surface sampling and ionization using a chip-based robotic nanoelectrospray platform [J].
Kertesz, Vilmos ;
Van Berkel, Gary J. .
JOURNAL OF MASS SPECTROMETRY, 2010, 45 (03) :252-260
[7]   High-throughput direct-infusion ion trap mass spectrometry: a new method for metabolomics [J].
Koulman, Albert ;
Tapper, Brian A. ;
Fraser, Karl ;
Cao, Mingshu ;
Lane, Geoffrey A. ;
Rasmussen, Susanne .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (03) :421-428
[8]   Direct infusion mass spectrometry or liquid chromatography mass spectrometry for human metabonomics? A serum metabonomic study of kidney cancer [J].
Lin, Lin ;
Yu, Quan ;
Yan, Xiaomei ;
Hang, Wei ;
Zheng, Jiaxin ;
Xing, Jinchun ;
Huang, Benli .
ANALYST, 2010, 135 (11) :2970-2978
[9]   High-Resolution Mass Spectrometers [J].
Marshall, Alan G. ;
Hendrickson, Christopher. L. .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2008, 1 :579-599
[10]   Stable isotope dilution microquantification of creatine metabolites in plasma, whole blood and dried blood spots for pharmacological studies in mouse models of creatine deficiency [J].
Tran, C. ;
Yazdanpanah, M. ;
Kyriakopoulou, L. ;
Levandovskiy, V. ;
Zahid, H. ;
Naufer, A. ;
Isbrandt, D. ;
Schulze, A. .
CLINICA CHIMICA ACTA, 2014, 436 :160-168