Development of a new high performance low pressure chromatographic system using a multisyringe burette coupled to a chromatographic monolithic column

被引:30
作者
Gonzalez-San Miguel, Hilda M.
Alpizar-Lorenzo, Jesus M.
Cerda-Martin, Victor [1 ]
机构
[1] Univ Balearic Isl, Dept Chem, Palma de Mallorca, Spain
[2] Univ Havana, Inst Food & Pharmaceut Sci, Dept Qual Assurance & Pharmaceut Technol, Havana, Cuba
[3] Univ Havana, Fac Chem, Dept Analyt Chem, Havana, Cuba
关键词
multisyringe liquid chromatography; MSC; monolithic column; amoxicillin; ampicillin; cephalexin; SEQUENTIAL INJECTION TECHNIQUE; SEPARATION;
D O I
10.1016/j.talanta.2006.09.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel combination of high performance low pressure chromatography with multisyringe flow injection analysis is presented. This system comprises a multisyringe module, three low pressure solenoid valves, a monolithic Chromolith Flash RP-18e column and a diode array spectrophotometer. UV detection is carried out at 250 nm. AutoAnalysis software is used for instrumental control and automated data collection. The results obtained with multisyringe liquid chromatography (MSC) were compared with those obtained with a HPLC system using similar conditions. The chromatographic parameters were calculated from a mixture of anthracene and thiourea using a mobile phase containing acetonitrile-water (60:40) at a flow rate of 2 ml min(-1). The proposed MSC system has been successfully applied. to the determination of amoxicillin, ampicillin and cephalexin using a mobile phase of sodium acetate buffer (pH 6.2, 0.1 mol1(-1))-methanol (90: 10) at a flow rate of 2 ml min(-1). The low-cost, flexibility and simplicity of MSC should be highlighted. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:296 / 300
页数:5
相关论文
共 13 条
[1]   Spectrophotometric determination of selected cephalosporins in drug formulations using flow injection analysis [J].
Al-Momani, IF .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (5-6) :751-757
[2]  
[Anonymous], INTRO METODOS ANAL F
[3]  
Becerra E, 1999, LAB ROBOTICS AUTOMAT, V11, P131, DOI 10.1002/(SICI)1098-2728(1999)11:3<131::AID-LRA2>3.0.CO
[4]  
2-9
[5]   Flow techniques in water analysis [J].
Cerdà, V ;
Estela, JM ;
Forteza, R ;
Cladera, A ;
Becerra, E ;
Altimira, P ;
Sitjar, P .
TALANTA, 1999, 50 (04) :695-705
[6]   DETERMINATION OF AMPICILLIN OR AMOXICILLIN IN PHARMACEUTICAL SAMPLES BY FLOW-INJECTION ANALYSIS [J].
GARCIA, MS ;
SANCHEZPEDRENO, C ;
ALBERO, MI ;
RODENAS, V .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (12) :1585-1589
[7]   Speciation analysis of inorganic arsenic by a multisyringe flow injection system with hydride generation-atomic fluorescence spectrometric detection [J].
Leal, LO ;
Forteza, R ;
Cerdà, V .
TALANTA, 2006, 69 (02) :500-508
[8]   Characterization formula for shear stress of polymer melt dynamic extruding through capillary [J].
Liu, YJ ;
Xu, BP ;
Shi, P ;
Ca, MW ;
Qu, JP .
POLYMERS & POLYMER COMPOSITES, 2005, 13 (04) :395-402
[9]  
*MERCK, CHROM COL GEN INF AP
[10]   Rapid and sensitive high-performance liquid chromatographic determination of four cephalosporin antibiotics in pharmaceuticals and body fluids [J].
Samanidou, VF ;
Hapeshi, EA ;
Papadoyannis, IN .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (01) :147-158