Identification and quantitative analysis of human transthyretin variants in human serum by Fourier transform ion-cyclotron resonance mass spectrometry

被引:8
|
作者
Da Costa, G. [1 ]
Gomes, R. [2 ]
Correia, C. F. [1 ]
Freire, A. [4 ]
Monteiro, E. [4 ]
Martins, A. [4 ]
Barroso, E. [4 ]
Coelho, A. V. [2 ,3 ]
Outeiro, T. F. [5 ]
Freire, A. Ponces [1 ]
Cordeiro, C. [1 ]
机构
[1] Univ Lisbon, Fac Ciencias, Dept Quim & Bioquim, Ctr Quim & Bioquim, Lisbon, Portugal
[2] Univ Nova Lisboa, Inst Tecnol Quim & Biol, Lab Espectrometria Massa, Oeiras, Portugal
[3] Univ Evora, Dept Quim, Evora, Portugal
[4] Hosp Curry Cabral, Unidade Transplantacao, Lisbon, Portugal
[5] Univ Lisbon, Fac Med, Inst Fisiol, Cell & Mol Neurosci Unit,Inst Med Mol, P-1699 Lisbon, Portugal
来源
AMYLOID-JOURNAL OF PROTEIN FOLDING DISORDERS | 2009年 / 16卷 / 04期
关键词
Transthyretin; familial amyloidotic polyneuropathy; systemic amyloidosis; FTICR; FAMILIAL AMYLOIDOTIC POLYNEUROPATHY; PORTUGUESE TYPE; PRE-ALBUMIN; PREALBUMIN; PROTEINS; MUTATIONS; DISEASE; FIBRIL;
D O I
10.3109/13506120903421561
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Transthyretin (TTR) is a homotetrameric protein involved in thyroid hormone transport in blood and in retinol binding in the central nervous system. More than 80 point mutations in this protein are known to be associated with the formation of amyloid deposits and systemic amyloidotic pathologies. Age at onset varies according to the mutation but considerable variations also occur for subjects carrying the same mutation. Moreover, wild-type TTR forms amyloid deposits in systemic senile amyloidosis, a geriatric disorder. An accurate diagnostic and the choice of therapeutic options depend on the identification of the specific mutation. Previous characterization of TTR variants by mass spectrometry required the use of antibodies for sample enrichment. We developed a novel assay based on ultra high-resolution mass spectrometry to identify human TTR variants. The method, requiring a very low sample amount, is based on SDS-PAGE fractionation of human serum, followed by peptide mass fingerprinting by MALDI-FTICR-MS (matrix assisted laser desorption ionization coupled to Fourier transform ion cyclotron resonance mass spectrometry). Moreover, it is possible to perform a relative quantification of wild type and mutant TTR forms by mass spectrometry. The method was tested and validated with the V30M mutant, involved in familial amyloidotic neuropathy of Portuguese type.
引用
收藏
页码:201 / 207
页数:7
相关论文
共 50 条
  • [41] Matrix-free mass spectrometric imaging using laser desorption ionisation Fourier transform ion cyclotron resonance mass spectrometry
    Goodwin, Richard J. A.
    Pitt, Andrew R.
    Harrison, David
    Weidt, Stefan K.
    Langridge-Smith, Pat R. R.
    Barrett, Michael P.
    Mackay, C. Logan
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (07) : 969 - 972
  • [42] MICRA: a compact permanent magnet Fourier transform ion cyclotron resonance mass spectrometer
    Mauclaire, G
    Lemaire, J
    Boissel, P
    Bellec, G
    Heninger, M
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2004, 10 (02) : 155 - 162
  • [43] Phase Correction of Fourier Transform Ion Cyclotron Resonance Mass Spectra Using MatLab
    Qi, Yulin
    Thompson, Christopher J.
    Van Orden, Steve L.
    O'Connor, Peter B.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2011, 22 (01) : 138 - 147
  • [44] A METHOD OF RATE-CONSTANT MEASUREMENT IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE PULSED VALVE EXPERIMENTS
    LIN, Y
    NICOL, GR
    RIDGE, DP
    EUROPEAN MASS SPECTROMETRY, 1995, 1 (02): : 113 - 119
  • [45] Rhapso: Automatic Stitching of Mass Segments from Fourier Transform Ion Cyclotron Resonance Mass Spectra
    Gavard, Remy
    Lozano, Diana Catalina Palacio
    Guzman, Alexander
    Rossell, David
    Spencer, Simon E. F.
    Barrow, Mark P.
    ANALYTICAL CHEMISTRY, 2019, 91 (23) : 15130 - 15137
  • [46] Peptide and protein characterization by high-rate electron capture dissociation Fourier transform ion cyclotron resonance mass spectrometry
    Tsybin, YO
    Ramström, M
    Witt, M
    Baykut, G
    Håkansson, P
    JOURNAL OF MASS SPECTROMETRY, 2004, 39 (07): : 719 - 729
  • [47] Structural identification and quantification of protein phosphorylations after gel electrophoretic separation using Fourier transform ion cyclotron resonance mass spectrometry and laser ablation inductively coupled plasma mass spectrometry
    Becker, JS
    Boulyga, SF
    Becker, JS
    Pickhardt, C
    Damoc, E
    Przybylski, M
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 228 (2-3) : 985 - 997
  • [48] Rapid microscale analyses with an external ion source Fourier transform ion cyclotron resonance mass spectrometer
    Heeren, RMA
    Boon, JJ
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1996, 157 : 391 - 403
  • [49] Note: Optimized circuit for excitation and detection with one pair of electrodes for improved Fourier transform ion cyclotron resonance mass spectrometry
    Chen, T.
    Beu, S. C.
    Kaiser, N. K.
    Hendrickson, C. L.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (06)
  • [50] Specific electrochemical iodination of horse heart myoglobin at tyrosine 103 as determined by Fourier transform ion cyclotron resonance mass spectrometry
    Iniesta, Jesus
    Cooper, Helen J.
    Marshall, Alan G.
    Heptinstall, John
    Walton, David J.
    Peterson, Ian R.
    ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 2008, 474 (01) : 1 - 7