Results of Pilot Comparisons of National Standards for the Activity of Hydrogen Ions in Aqueous Solutions

被引:0
作者
Prokunin, S. V. [1 ]
Shchipunov, A. N. [1 ]
Vengina, D. A. [1 ]
Bastkowskiy, F. [2 ]
Uysal, E. [3 ]
Mkrtichyan, S. [4 ]
Zhanasbaeva, B. K. [5 ]
Beskupskiy, A. [6 ]
Tabullo, O. B. [7 ]
Zolotorevich, E. A. [8 ]
Petrenko, A. V. [9 ]
机构
[1] Russian Metrol Inst Tech Phys & Radio Engn VNIIFT, Mendeleyevsk, Russia
[2] Phys Tech Bundesanstalt PTB, Braunschweig, Germany
[3] TUBITAK UME Natl Metrol Inst TUBITAK UME, Kocaeli, Turkey
[4] Georgian Natl Agcy Stand & Metrol GeoSTM, Inst Metrol, Tbilisi, Georgia
[5] Kazakhstan Inst Metrol KazInMetr, Astana, Kazakhstan
[6] Natl Inst Metrol INM, Kishinev, Moldova
[7] Minist Econ Kyrgyz Republ Kyrgyzstandart, Ctr Standardizat & Metrol, Bishkek, Kyrgyzstan
[8] Belarusian State Inst Metrol BelGIM, Minsk, BELARUS
[9] All Ukrainian State Sci & Prod Ctr Standardizat M, Kiev, Ukraine
关键词
pH standard; primary standard; comparisons; buffer solution; metrology; standards; potentiometry; PH;
D O I
10.1007/s11018-021-01898-1
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The enormous need for support of measurements of the hydrogen index (pH) in various branches of industry and the national economy of Russia make measurement of pH one of the most important methods for monitoring aqueous media. In 2013 work was carried out to introduce into the State Register of Means of Measurement of the Russian Federation a buffer solution and titration standard with a pH value of 7.00, a 2nd order working standard for pH which is one of the nonstandard solutions most in demand for verification and calibration of instruments for measuring pH. The metrological characteristics of the 2nd order working standard for pH have been confirmed in pilot comparisons through COOMET (COOMET project 655/RU/15). The results of a pilot comparison for determination of the pH of a phosphate buffer solution with pH=7.00 are presented here. 8 metrological institutes and 10 metrological organizations took part in the comparisons. The results showed that the overwhelming majority of the participants in the comparisons obtained results for the pH measurements with an uncertainty that did not exceed +/- 0.03 of the average value, which is an acceptable criterion for pH measurements.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 10 条
  • [1] [Anonymous], ESTIMATING FUNCTIONS
  • [2] On the validity of acidity function extrapolation to zero added ionic strength and its impact on the uncertainty of primary pH measurements using the Harned cell
    Brown, Richard J. C.
    Brewer, Paul J.
    Milton, Martin J. T.
    [J]. MEASUREMENT, 2013, 46 (05) : 1726 - 1733
  • [3] Measurement of pH. Definition, standards, and procedures
    Buck, RP
    Rondinini, S
    Covington, AK
    Baucke, FGK
    Brett, CMA
    Camoes, MF
    Milton, MJT
    Mussini, T
    Naumann, R
    Pratt, KW
    Spitzer, P
    Wilson, GS
    [J]. PURE AND APPLIED CHEMISTRY, 2002, 74 (11) : 2169 - 2200
  • [5] SIMPLIFIED STATISTICS FOR SMALL NUMBERS OF OBSERVATIONS
    DEAN, RB
    DIXON, WJ
    [J]. ANALYTICAL CHEMISTRY, 1951, 23 (04) : 636 - 638
  • [6] ANALYSIS OF EXTREME VALUES
    DIXON, WJ
    [J]. ANNALS OF MATHEMATICAL STATISTICS, 1950, 21 (04): : 488 - 506
  • [7] Role of the activity coefficient in the dissemination of pH: comparison of primary (Harned cell) and secondary (glass electrode) measurements on phosphate buffer considering activity and concentration scales
    Fisicaro, P
    Ferrara, E
    Prenesti, E
    Berto, S
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (02) : 341 - 348
  • [8] COMPARISONS OF WORKING pH STANDARDS OF NATIONAL METROLOGICAL INSTITUTES IN COOMET
    Karpov, O. V.
    Kutovoy, V. D.
    Zvezdina, V. A.
    Lukashov, I. A.
    Kazakova, M. V.
    [J]. MEASUREMENT TECHNIQUES, 2010, 53 (01) : 40 - 50
  • [9] Karpov O. V., 1985, ZAKONODAT PRIKL METR, P7
  • [10] Prokunin S. V, 2015, RUSSIAN METROLOGICAL, V1, P383