Geometric and dosimetric accuracy of deformable image registration between average-intensity images for 4DCT-based adaptive radiotherapy for non-small cell lung cancer

被引:7
|
作者
He, Yulun [1 ]
Cazoulat, Guillaume [1 ]
Wu, Carol [2 ]
Peterson, Christine [3 ]
McCulloch, Molly [1 ]
Anderson, Brian [1 ]
Pollard-Larkin, Julianne [4 ]
Balter, Peter [4 ]
Liao, Zhongxing [5 ]
Mohan, Radhe [4 ]
Brock, Kristy [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Biostat, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
来源
关键词
4DCT; adaptive radiotherapy; deformable image registration accuracy; non-small cell lung cancer; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; DOSE ACCUMULATION; TUMOR MOTION; CT IMAGES; PROJECTION; DATASET; MAXIMUM; EXHALE; INHALE;
D O I
10.1002/acm2.13341
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Re-planning for four-dimensional computed tomography (4DCT)-based lung adaptive radiotherapy commonly requires deformable dose mapping between the planning average-intensity image (AVG) and the newly acquired AVG. However, such AVG-AVG deformable image registration (DIR) lacks accuracy assessment. The current work quantified and compared geometric accuracies of AVG-AVG DIR and corresponding phase-phase DIRs, and subsequently investigated the clinical impact of such AVG-AVG DIR on deformable dose mapping. Methods and Materials Hybrid intensity-based AVG-AVG and phase-phase DIRs were performed between the planning and mid-treatment 4DCTs of 28 non-small cell lung cancer patients. An automated landmark identification algorithm detected vessel bifurcation pairs in both lungs. Target registration error (TRE) of these landmark pairs was calculated for both DIR types. The correlation between TRE and respiratory-induced landmark motion in the planning 4DCT was analyzed. Global and local dose metrics were used to assess the clinical implications of AVG-AVG deformable dose mapping with both DIR types. Results TRE of AVG-AVG and phase-phase DIRs averaged 3.2 +/- 1.0 and 2.6 +/- 0.8 mm respectively (p < 0.001). Using AVG-AVG DIR, TREs for landmarks with <10 mm motion averaged 2.9 +/- 2.0 mm, compared to 3.1 +/- 1.9 mm for the remaining landmarks (p < 0.01). Comparatively, no significant difference was demonstrated for phase-phase DIRs. Dosimetrically, no significant difference in global dose metrics was observed between doses mapped with AVG-AVG DIR and the phase-phase DIR, but a positive linear relationship existed (p = 0.04) between the TRE of AVG-AVG DIR and local dose difference. Conclusions When the region of interest experiences <10 mm respiratory-induced motion, AVG-AVG DIR may provide sufficient geometric accuracy; conversely, extra attention is warranted, and phase-phase DIR is recommended. Dosimetrically, the differences in geometric accuracy between AVG-AVG and phase-phase DIRs did not impact global lung-based metrics. However, as more localized dose metrics are needed for toxicity assessment, phase-phase DIR may be required as its lower mean TRE improved voxel-based dosimetry.
引用
收藏
页码:156 / 167
页数:12
相关论文
共 50 条
  • [1] Dosimetric Study of the Deformable Image Registration based Lung Cancer Adaptive Radiotherapy
    Wang, Linjing
    Zhang, Shuxu
    Yuan, Kehong
    Zhou, Lu
    Wang, Ruihao
    2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 402 - 406
  • [2] Evolution of surface-based deformable image registration for adaptive radiotherapy of non-small cell lung cancer (NSCLC)
    Guckenberger, Matthias
    Baier, Kurt
    Richter, Anne
    Wilbert, Juergen
    Flentje, Michael
    RADIATION ONCOLOGY, 2009, 4
  • [3] Evalution of surface-based deformable image registration for adaptive radiotherapy of non-small cell lung cancer (NSCLC)
    Matthias Guckenberger
    Kurt Baier
    Anne Richter
    Juergen Wilbert
    Michael Flentje
    Radiation Oncology, 4
  • [4] CALIPER: A deformable image registration algorithm for large geometric changes during radiotherapy for locally advanced non-small cell lung cancer
    Guy, Christopher L.
    Weiss, Elisabeth
    Christensen, Gary E.
    Jan, Nuzhat
    Hugo, Geoffrey D.
    MEDICAL PHYSICS, 2018, 45 (06) : 2498 - 2508
  • [5] A Controlled Study of Dose Accumulation in Intensity-Modulated Radiotherapy for Non-Small Cell Lung Cancer Based On Rigid Registration and Deformable Registration
    Ren, J.
    Gong, G.
    Yin, Y.
    Quan, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E385 - E385
  • [6] Dosimetric and geometric evaluation of the use of deformable image registration in adaptive intensity-modulated radiotherapy for head-and-neck cancer
    Eiland, R. B.
    Maare, C.
    Sjostrom, D.
    Samsoe, E.
    Behrens, C. F.
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (05) : 1002 - 1008
  • [7] Application of 4DCT and Enhanced CT Image Deformation Registration in the Determination of Non-Small Cell Lung Cancer Radiotherapy Target
    Ma, C.
    Yin, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E340 - E340
  • [8] Toxicity and dosimetric analysis of non-small cell lung cancer patients undergoing radiotherapy with 4DCT and image-guided intensity modulated radiotherapy: a regional centre's experience
    Livingston, Gareth C.
    Last, Andrew J.
    Shakespeare, Thomas P.
    Dwyer, Patrick M.
    Westhuyzen, Justin
    McKay, Michael J.
    Connors, Lisa
    Leader, Stephanie
    Greenham, Stuart
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2016, 63 (03) : 170 - 178
  • [9] Accuracy and consistency of intensity-based deformable image registration in 4DCT for tumor motion estimation in liver radiotherapy planning
    Tascon-Vidarte, Jose D.
    Stick, Line Bjerregaard
    Josipovic, Mirjana
    Risum, Signe
    Jomier, Julien
    Erleben, Kenny
    Vogelius, Ivan Richter
    Darkner, Sune
    PLOS ONE, 2022, 17 (07):
  • [10] 4DCT Based Lung Elastography for Regional Lung Functionality Preservation in Radiotherapy of Non-small Cell Lung Cancer
    Santhanam, A.
    Neylon, J.
    Hasse, K.
    O'Connell, D.
    Low, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E494 - E494