Determination of mercury in hepatitis-B vaccine by electrolyte cathode glow discharge atomic emission spectrometry (ELCAD-AES)

被引:39
作者
Shekhar, R. [1 ]
Karunasagar, D. [1 ]
Dash, K. [1 ]
Ranjit, Manjusha [1 ]
机构
[1] Bhabha Atom Res Ctr, Natl Ctr Composit Characterizat Mat, Hyderabad 500062, Andhra Pradesh, India
关键词
ABSORPTION-SPECTROMETRY; TRACE-METALS; WATER; EXTRACTION; URINE;
D O I
10.1039/b927010h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, rapid and sensitive method has been developed for the determination of mercury in Hepatitis-B vaccine samples using electrolyte cathode glow discharge atomic emission spectrometry (ELCAD-AES). This method obviates the need of any sample digestion, except simple dilution followed by analysis of the vaccine samples. Analytical performance of the ELCAD-AES for the inorganic as well as the organic mercury (methyl and thiomersal mercury) in the aqueous solutions is investigated. Biological certified reference materials, Tuna fish-IAEA-350 and Tuna fish-BCR-463 are examined for the applicability of ELCAD-AES to quantify the mercury. These results show an accuracy of between 0.6 to 2.1% with an analytical precision expressed as relative standard deviation (RSD%) of between 3 to 7% based on the multiple measurements on multiple sample loadings. In the absence of any CRM of the vaccine sample, the method has been validated by analyzing the same samples by Cold vapour-AAS and Electrothermal-AAS. Accuracy of the ELCAD results for vaccine samples is determined to be within 2 to 9% at various levels of mercury. Detection limit of the method is found to be 25 ng mL(-1) and the analytical precision is between 2-5%.
引用
收藏
页码:875 / 879
页数:5
相关论文
共 37 条
[1]  
BLOXHAM MJ, 1996, J ANAL ATOM SPECTROM, P7511
[2]   Determination of mercury in gasoline by cold vapor atomic absorption spectrometry with direct reduction in microemulsion media [J].
Brandao, GP ;
de Campos, RC ;
Luna, AS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (05) :625-631
[3]   Noble metals as permanent modifiers for the determination of mercury by electrothermal atomic absorption spectrometry [J].
Bulska, E ;
Kandler, W ;
Hulanicki, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (9-10) :1263-1270
[4]  
Cserfalvi T, 1996, FRESEN J ANAL CHEM, V355, P813
[5]   DIRECT SOLUTION ANALYSIS BY GLOW-DISCHARGE - ELECTROLYTE-CATHODE DISCHARGE SPECTROMETRY [J].
CSERFALVI, T ;
MEZEI, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :345-349
[6]   EMISSION STUDIES ON A GLOW-DISCHARGE IN ATMOSPHERIC-PRESSURE AIR USING WATER AS A CATHODE [J].
CSERFALVI, T ;
MEZEI, P ;
APAI, P .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (12) :2184-2188
[7]   Subnanogram sensitive multimetal detector with atmospheric electrolyte cathode glow discharge [J].
Cserfalvi, T ;
Mezei, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (06) :596-602
[8]  
Dash K, 2009, ATOM SPECTROSC, V30, P26
[9]   Sensitive determination of mercury in tap water by cloud point extraction pre-concentration and flow injection-cold vapor-inductively coupled plasma optical emission spectrometry [J].
de Wuilloud, JCA ;
Wuilloud, RG ;
Silva, MF ;
Olsina, RA ;
Martinez, LD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (02) :365-374
[10]  
Gubkin J., 1887, ANN PHYS-NEW YORK, V32, P114, DOI [10.1002/andp.18872680909, DOI 10.1002/ANDP.18872680909]